Product Description

The TGLS is a contractor grade Troffer that will exceed quality and performance for most commercial spaces. The TGLS LED Troffer features a pre- mounted driver and a maintenance-free, fully sealed chamber with seamless aluminum frame to keep bugs and dust out. The fixture utilizes a precision- engineered, textured diffuser to deliver maximum lumen output and optimal uniformity without revealing hot spots or shadowing. Offering CCT selection with the choice of 3500K, 4000K, or 5000K CCT with DLC 5.1 Standard certification, ensuring top of the line quality and performance, the TGL is the perfect lighting solution for offices, hospitals, and other commercial spaces.

Construction

  • Extruded aluminum frame with powder coat finish
  • Durable stamped housing
  • High efficiency, maintenance-free LED chamber
  • Smooth formed sides for safe handling

Optical System

  • Patented internal optical system
  • Precision engineered polystyrene diffuser
  • High reflectivity internal coating
  • No visible diodes, hot-spots, or shadows providing high uniformity, and reduced glare
  • 80 CRI for good color definition in public places

Electrical

  • Input voltage of 120-277VAC
  • CCT selector switch accessible on junction box
  • Full-range dimming via 1-10VDC controls
  • Power factor > 0.9
  • THD < 20%
  • Luminaire surge protection level: designed to withstand up to 2.5kV ring wave per ANSI C82.77-5-2017 requirements for Indoor Hard-wired and Indoor Portable Luminaires
  • Operating temperature range: 4°F to 104°F (-20° to 40°C)

Mounting and installation

  • Single cover plate with access to both line and low voltage connections
  • Emergency battery backup available
  • Integral grid tie clips with wire holes provided for seismic requirements
  • Surface mount installation with an optional adapter
  • Drywall installation with an optional adaptor
  • For installations where power surge may be possible, NICOR recommends installing additional surge protection at the fixture or electrical distribution panel

Listings

  • cULus 1598 Listed for damp locations
  • Certified for direct contact with insulation (IC)
  • DLC 5.1 Standard listed
  • RoHS Compliant
  • Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions
  • TM-21 Reported L70(9k) life >54,000 hours
  • LM-79, LM-80 testing performed in accordance with IESNA standards

Warranty

  • 5-year limited system warranty standard

  • Warranty does not cover product failure due to an overvoltage event (power surge.)

  • Project

  • Catalog

  • Type

  • Date

TGLS
LED Backlit Troffer
2×2, 2×4
Selectable CCT

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107
P: 800.821.6283
F: 800.892.8393 www.nicorlighting.com
August 22, 2022 10:04 AM TGLS1

Ordering

Ordering Information Example: TGLS122U
Series Size Voltage EM (Optional)
TGLS1 22 (2 x 2) U (120-277V) E1 (EMB045)
![NICOR-TGLS-Select-LED-Backlit-Troffer-04](https://manuals.plus/wp-

content/uploads/2023/03/NICOR-TGLS-Select-LED-Backlit-Troffer-04.png) 24 (2 x 4)| | E2 (EMB080)

Specifications and dimensions subject to change without notice.

Accessories

  • Surface Mount Kit – 2×2 TPE10SK22
  • Surface Mount Kit for use with E1/E2 – 2×2 SK22M10WH
  • Flange Kit – 2×2 TPE10FK22
  • Surface Mount Kit – 2×4 TPE10SK24
  • Surface Mount Kit for use with E1/E2 – 2×4 SK24M10WH
  • Flange Kit – 2×4 TPE10FK24

**Recommended Dimmers***

  • Lutron NTSTV
  • Lutron DVSTV
  • Cooper SF10P
  • Legrand RH4FBL3PW

*Not a complete list.
Check compatibility before installation.

Photometric Data

Performance Data Emergency Pack Performance Data

Model| Nominal CCT| Lumens| Watts| Efficiency| E1Lumens| E2Lumens
| 3500| 4681| | 114| 514| 913
TGLS122U| 4000| 4845| 41.0| 118| 532| 945
| 5000| 4779| | 117| 525| 932
| 3500| 5513| | 112| 505| 898
TGLS124U| 4000| 5706| 49.1| 116| 523| 930
| 5000| 5629| | 115| 516| 917

TGLS122 3500K

  • Input Voltage (VAC) 120-277
  • System Level Power (W) 41.0
  • Delivered Lumens (Lm) 4681
  • System Efficacy (Lm/W) 114.2
  • Correlated Color Temp (K) 3487
  • Color Rendering Index (CRI) 83
  • Beam Angle (0) 116.2
  • Beam Angle (90) 114.8
  • Spacing Criteria (0) 1.26
  • Spacing Criteria (90) 1.30

Cone of Light Tabulation

Mounted height (Feet)| Footcandles Beam Center| Diameter (Feet)
8| 24.4| 25.7
10| 15.6| 32.1
12| 10.8| 38.6
14| 7.9| 45.0
Data Multiplier

TGLS122U
3500K| 1.000
4000K| 1.035
5000K| 1.021

TGLS124 3500K

  • Input Voltage (VAC) 120-277
  • System Level Power (W) 49.1
  • Delivered Lumens (Lm) 5513
  • System Efficacy (Lm/W) 112.3
  • Correlated Color Temp (K) 3512
  • Color Rendering Index (CRI) 82
  • Beam Angle (0) 115.6
  • Beam Angle (90) 120.6
  • Spacing Criteria (0) 1.32
  • Spacing Criteria (90) 1.30

Cone of Light Tabulation

Mounted height (Feet)| Footcandles Beam Center| Diameter (Feet)
8| 28.1| 25.4
10| 17.9| 31.8
12| 12.4| 38.1
14| 9.1| 44.5
Data Multiplier

TGLS124U
3500K| 1.00
4000K| 1.035
5000K| 1.021

Dimensions

NICOR-TGLS-Select-LED-Backlit-Troffer-07

Specifications and dimensions subject to change without notice.

This device complies with part 15 of the FCC Rules.

Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reason-able protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107
P: 800.821.6283
F: 800.892.8393
www.nicorlighting.com
August 22, 2022 10:04 AM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals