Product Description

The TGLS2 is a contractor grade Troffer that will exceed quality and performance for most commercial spaces. The TGLS2 LED Troffer features a pre- mounted driver and a maintenance-free, fully sealed chamber with seamless aluminum frame to keep bugs and dust out. The fixture utilizes a precision- engineered, textured diffuser to deliver maximum lumen output and optimal uniformity without revealing hot spots or shadowing. Available with CCT and lumen output Selectable options with the choice of 3500K, 4000K, or 5000K CCTs and low, medium, and high lumen output. Now with DLC 5.1 Standard certification, ensuring top of the line quality and performance. The TGL is the perfect lighting solution for offices, hospitals, and other commercial spaces.

Construction

  • Extruded aluminum frame with powder coat finish
  • Durable stamped housing
  • High efficiency, maintenance-free LED chamber
  • Smooth formed sides for safe handling

Optical System

  • Patented internal optical system
  • Precision engineered polystyrene diffuser
  • High reflectivity internal coating
  • No visible diodes, hot-spots, or shadows providing high uniformity, and reduced glare
  • 80 CRI for good color definition in public places

Electrical

  • Input voltage of 120-277VAC
  • CCT selector switch accessible on junction box
  • Full-range dimming via 1-10VDC controls
  • Power factor > 0.9
  • THD < 20%
  • Luminaire surge protection level: designed to withstand up to 2.5kV ring wave per ANSI C82.77-5-2017 requirements for Indoor Hard-wired and Indoor Portable

Luminaires

  • Operating temperature range: 4°F to 104°F (-20° to 40°C)

Controls

  • NLC (Network Lighting Controls) option available
  • Bluetooth Low Energy (BLE) mesh network providing Luminaire Level Lighting Control
  • Luminaire integrated BLE PIR/Daylight sensor (N1) available
  • Configurable with the NICOR NLC app available on iOS and Android devices
  • Provides full dimming control with occupancy and daylight harvesting functions

Mounting and installation

  • Single cover plate with access to both line and low voltage connections
  • Emergency battery backup available
  • Integral grid tie clips with wire holes provided for seismic requirements
  • Surface mount installation with an optional adapter
  • Drywall installation with an optional adaptor
  • For installations where power surge may be possible, NICOR recommends installing additional surge protection at the fixture or electrical distribution panel

Listings

  • cULus 1598 Listed for damp locations
  • Certified for direct contact with insulation (IC)
  • RoHS Compliant
  • DLC 5.1 Listing
  • Meets FCC Part 15, Subpart B, Class A standards for conducted and radiated emissions
  • TM-21 Reported L70(9k) life >54,000 hours
  • LM-79, LM-80 testing performed in accordance with IESNA standards

Warranty

  • 5-year limited system warranty standard
  • Warranty does not cover product failure due to an overvoltage event (power surge.)

Ordering

Ordering Information

Series| Version| Size| Voltage| Controls| EM (Optional)
---|---|---|---|---|---
TGLS| 2| 14 (1 x 4)| U (120-277V)| Blank (none)| Blank (none)
| | 22 (2 x 2)| | N1 (NLC Controls)| E1 (EMB045)
| | 24 (2 x 4)| | | E2 (EMB080)

Accessories

Surface Mount Kit – 1×4 TPE10SK14
Surface Mount Kit for use with E1/E2 – 1×4 SK14M10WH
Flange Kit – 1×4 TPE10FK14
Surface Mount Kit – 2×2 TPE10SK22
Surface Mount Kit for use with E1/E2 – 2×2 SK22M10WH
Flange Kit – 2×2 TPE10FK22
Surface Mount Kit – 2×4 TPE10SK24
Surface Mount Kit for use with E1/E2 – 2×4 SK24M10WH
Flange Kit – 2×4 TPE10FK24

**Recommended Dimmers**
Lutron NTSTV
Lutron DVSTV
Cooper SF10P
Legrand RH4FBL3PW
Not a complete list.
Check compatibility before installation.

NLC Controls
See www.nicorlighting/network-lighting-controls for more information and NLC Component Data Sheets

Photometric Data

Performance Data| Emergency Pack Performance
Data
---|---
Model| Output Setting| Nominal CCT| Lumens| Max Watts| Efficiency| E1 Lumens| E2 Lumens
TGLS214U| Standard| 3500
4000
5000| 2331
2412
2367| 19.6| 119
126
121| 536
567
545| 952
1008
968
Medium| 3500
4000
5000| 3440
3604
3489| 29.8| 115
125
117| 518
563
527| 920
1000
936
High| 3500
4000
5000| 4698
4931
4651| 42.8| 109
120
110| 491
540
495| 872
960
880
TGLS222U| Standard| 3500
4000
5000| 2486
2573
2516| 22| 113
117
114| 515
526
509| 915
936
904
Medium| 3500
4000
5000| 3724
3894
3755| 32.8| 114
119
114| 515
534
511| 916
950
908
High| 3500
4000
5000| 4763
4998
4772| 42.6| 112
117
112| 504
528
503| 896
939
894
TGLS224U| Standard| 3500
4000
5000| 3686
3767
3664| 31| 119
122
118| 532
547
535| 946
972
951
Medium| 3500
4000
5000| 5029
5184
4996| 43| 117
121
116| 523
543
526| 929
964
936
High| 3500
4000
5000| 5949
6164
5926| 52.1| 114
118
114| 512
532
514| 910
946
913

TGLS214 3500K High Output

Input Voltage (VAC) 120-277
System Level Power (W) 42.6
Delivered Lumens (Lm) 4772
System Efficacy (Lm/W) 112
Correlated Color Temp (K) 3437
Color Rendering Index (CRI) 83
Beam Angle (0) 115.6
Beam Angle (90) 115.2
Spacing Criteria (0) 1.3
Spacing Criteria (90) 1.28

Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
8 24 25.4
10 15.3 31.8
12 10.6 38.1
14 7.8 44.5

Data Multiplier
TGLS214U

| 35K| 40K| 50K
---|---|---|---
Low| 0.5| 0.52| 0.51
Med| 0.74| 0.77| 0.75
High| 1.00| 1.06| 1.01

TGLS222 3500K High Output

Input Voltage (VAC) 120-277
System Level Power (W) 42.6
Delivered Lumens (Lm) 4772
System Efficacy (Lm/W) 112
Correlated Color Temp (K) 3437
Color Rendering Index (CRI) 83
Beam Angle (0) 115.6
Beam Angle (90) 115.2
Spacing Criteria (0) 1.3
Spacing Criteria (90) 1.28

NICOR TGLS2 Select LED Backlit Troffer - High Output1

Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
8 25.1 25.4
10 16 31.8
12 11.1 38.1
14 8.2 44.5

Data Multiplier
TGLS222U

| 35K| 40K| 50K
---|---|---|---
Low| 0.52| 0.54| 0.53
Med| 0.78| 0.82| 0.79
High| 1.00| 1.05| 1.00

TGLS224 3500K High Output

Input Voltage (VAC) 120-277
System Level Power (W) 52.1
Delivered Lumens (Lm) 5926
System Efficacy (Lm/W) 114
Correlated Color Temp (K) 3448
Color Rendering Index (CRI) 83
Beam Angle (0) 115.7
Beam Angle (90) 120.7
Spacing Criteria (0) 1.32
Spacing Criteria (90) 1.28

Cone of Light Tabulation

Mounted height (Feet) Footcandles Beam Center Diameter (Feet)
8 30.4 25.5
10 19.4 31.8
12 13.5 38.2
14 9.9 44.5

Data Multiplier
TGLS224U

| 35K| 40K| 50K
---|---|---|---
Low| 0.62| 0.64| 0.62
Med| 0.85| 0.87| 0.84
High| 1.00| 1.04| 1.00

Dimensions

NICOR TGLS2 Select LED Backlit Troffer - Dimensions

Specifications and dimensions subject to change without notice.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Project____
Catalog____
Type__
Date__

NICOR, Inc. 2200 Midtown Place NE, Albuquerque, NM 87107 P: 800.821.6283 F: 800.892.8393
www.nicorlighting.com December 19, 2022 9:40 AM TGLS2 Page 4 of 4

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

NICOR User Manuals

Related Manuals