GYS PSW 601W Battery Charger Power Inverter User Manual
- June 9, 2024
- GYS
Table of Contents
- GYS PSW 601W Battery Charger Power Inverter
- SAFETY INSTRUCTIONS
- DESCRIPTION
- STRUCTURE INTRODUCTION
- APPLICATION INSTRUCTION
- CONNECTION
- DISCONNECTION
- REMOTE CONTROL
- PROTECT FUNCTION AND RESTART WORK METHOD
- VOLTAGE AND TEMPERATURE PERFORMANCE
- WARRANTY
- CHARACTERISTICS
- RECOMMENDATIONS
- GYS SAS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
GYS PSW 601W Battery Charger Power Inverter
SAFETY INSTRUCTIONS
This manual includes guidelines on the operation of your device and the precautions to follow for your own safety. Ensure it is read carefully before first use and keep it handy for future reference. These instructions should be read and understood before anyone operates the product. Any modifications or maintenance that are not specified in the manual should not be undertaken. The manufacturer is not liable for any injury or damage due to non-compliance with the instruction manual. In case of problems or uncertainties, please consult a qualified person that is able to handle the device correctly. This device should only be used within the limits indicated on the device and in the manual. The safety instructions must be followed. In case of improper or unsafe use, the manufacturer cannot be held responsible.
- Device suitable for indoor use only. Do not expose to rain or excessive moisture.
- Do not cover the device
- Do not place the device near a fire or subject it to heat or to longterm temperatures exceeding 50°C
- Do not obstruct the cooling vents. Refer to the installation section before operating the machine.
- The automatic mode of operation and usage restrictions are explained below in these operating instructions.
Risk of explosion and fire!
- A battery being charged can emit explosive gas.
- During the charge, the battery must be placed in a well ventilated area.
- Avoid flames and sparks. Do not smoke.
- Protect the electrical contacts of the battery against shortcircuiting.
Acid projection hazard
- Wear safety goggles and protective gloves
- If your eyes or skin come into contact with battery acid, rinse the affected part of the body with plenty of water and seek immediate medical assistance.
Connection
- This machine is fuse-protected
Maintenance
- Service should be performed by a qualified person
- Under no circumstances should solvents or other aggressive cleaning agents be used.
- Clean the device’s surfaces with a soft, dry cloth.
Regulations
- The device complies with European Directive.
- The certificate of compliance is available on our website.
- EAC conformity mark (Eurasian Economic Commission)
- Equipment in compliance with British requirements. The British Declaration of Conformity is available on our website.
- Equipment in conformity with Moroccan standards.
- The declaration C م (CMIM) of conformity is available on our website.
Disposal
This product should be disposed of at an appropriate recycling facility. Do not dispose of in the domestic waste.
DESCRIPTION
The inverter converter PSW (Pure Sinus Wave) is a device that converts a DC voltage of 12 V or 24 V into an AC voltage of 230 V. This product is widely used for various applications such as vehicles, structures and mobile devices for telecommunications, public safety, emergency, etc. This converter has the advantage of being small, lightweight, stable and highly efficient in conversion. It is equipped with 5 protections: input under/overvoltage protection, overload protection, overtemperature protection, output shortcircuit protection.
STRUCTURE INTRODUCTION
PSW 601 W
- AC Output Sockets
- Power Indicator (Green)
- Fault Indicator (Red)
- ON/OFF Switch
- USB Output
- Remote Port
- DC Input « + » Terminal (Red)
- DC Input « – » Terminal (Black)
- FAN
- Earth
PSW 1002 W / 1502 W / 2002 W
- AC Output Sockets
- Power Indicator (Green)
- Fault Indicator (Red)
- ON/OFF Switch
- USB Output
- Remote Port
- DC Input « + » Terminal (Red)
- DC Input « – » Terminal (Black)
- FAN
- Earth
- Battery cables (red = positive; black = negative)
- Earth clamp (green and yellow cable)
Converter | Ref | Ref UK | Cable length/section |
---|---|---|---|
PSW 601W – 12 V | 067332 | 067349 | 6 mm²/48 cm (red + black) |
PSW 1002W – 12 V | 067356 | 067363 | 10 mm²/48 cm (red + black) |
PSW 1502W – 12 V | 067370 | 067387 | 16 mm²/48 cm (red + black) |
PSW 2002W – 12 V | 067394 | 067400 | 22 mm²/48 cm (red + black) |
PSW 2002W – 24 V | 067417 | 067424 | 12 mm²/48 cm (red + black) |
APPLICATION INSTRUCTION
Scope of application
Only use for class appliance
Electric power tool series Electric Saw,Drilling machine,lapping machine,sandblast machine,stamping machina,grass eliminator,air compressor;
- Office equipment: Computer,printer,displayer, duplicator,scanistor,facsimile apparatus…
- Household appliances: dust collector,fan, fluorescent lamp,filament lamp,sewing machine;
- Kitchen series: Mircowave oven, refrigerator,freezer,coffe machine,blender, ice machine;hot oven;
- Commercial installation series: Metal halogen light,high voltage sodium lam, watercraft,cars, solar energy andwind power generation;
- Electric Field series: TV, radio,game player,VCR, power amplifier; monitoring equipment, servicer,satellite communication euqipments
_ Notice: _While using please follow the related power of the inverter , do not overload.It is better to keep the inverter work at 85% of it’s related power.
Scope of electric appliance that inapplicability with the USB
- Only for inverters with USB port ;
- USB is only for charging , do not have date exchange function;
- Before charging please check carefully if the charging current of the appliance is under the inverters current, if it is exceed the charging current of the inverter please do not use, or it may destroy the USB port.
- Some appliance must charging use certain charger, please don’t charge with USB port.
- To save energy, the fan will not work unless the under two situations:
- The fan will work when the load is exceed 30% of the related power of the inverter;
- When the inside temperature of the inverter exceed 60 degree, fan work.
- About extended cable using:
- We do not recommend use extended cable between the inverter and the battery, because it will case lost of DC electricity and affect the effect of the inverter.
- If you must use an extension cable, we recommend using high quality cables with larger cross-sections to reduce the risk of electrical losses.
CONNECTION
- Make sure that the input voltage of the converter corresponds to the battery voltage (12 V or 24 V).
- Until it is indicated to switch it on, the converter should remain switched off.
- Connect the converter to the battery with the cables supplied.
- Observe the following steps in order.
- Connect the black cable to the negative terminal of the converter and then the red cable to the positive terminal of the converter.
- After each connection, replace the red and black plastic covers. They prevent the connections from coming into contact with metal parts and causing a short circuit.
- Connect the black cable to the negative terminal of the battery, and then connect the red cable to the positive terminal of the battery.
- Check the connection before the next step. Do not invert the connection as this may damage the converter.
- Set the switch to the «ON» position, the green light will come on, the product is ready for use. If the alarm goes off, switch off the product and refer to the list of alerts.
DISCONNECTION
To disconnect the converter, follow the steps below in order:
- Disconnect the red terminal from the battery terminals, then the black terminal.
- Disconnect the red cable from the positive terminal of the converter, then the black cable from the negative terminal of the converter.
WARNING: Once each cable has been disconnected, replace the red and black plastic covers on the converter connectors.
REMOTE CONTROL
PSW 601 W
PSW 1002 W / 1502 W / 2002 W Connection
- The monitoring remote control must be connected to the converter when it is not energised.
- Connect the remote control to the converter (1).
- The remote control can be fixed once the connection has been established.
On / Off button
- The remote control allows the converter to be controlled remotely (max. 5 m).
- WARNING: The On/Off function of the remote control only works if the main switch of the converter is set to Off.
- Press the button (2) for a long time (> 3 s). The converter lights up, the Power LED turns green.
- Repeat the same operation to switch off the inverter.
Digital display (remote control PSW 1002W / 1502W / 2002W)
- The “INPUT DISPLAY” screen gives information about the battery voltage.
- The “OUTPUT DISPLAY” screen informs about the power consumption of the device connected to the converter.
- A simple press of the button (2) switches between the two displays.
Indicators
The green indicator is the power indicator. The red indicator indicates a fault:
E0 | E1 | E2 | E3 | E4 |
---|---|---|---|---|
Low volt | Over volt | Over temp | Over load | Output short-circuit |
PROTECT FUNCTION AND RESTART WORK METHOD
Function | State description | Restart work method |
---|---|---|
LED light | alarm | AC output |
Input low voltage alarm | Green: on |
Red: off
| Alarm| AC have output| When the voltage of the batter return to the related
voltage, alarm stop automatically.
Input low
voltage shut down
| Green: on Red: on| ****
Alarm
| ****
No AC output
| When the voltage of the batter return to the related voltage the inverter
will restart work, green light on, red light off.
Input over-voltage protection| Green: on Red: on| ****
Alarm
| ****
No AC output
| When the voltage of the batter return to the related voltage the inverter
will restart work, green light on, red light off.
Over load protection| Green: on Red: on| Alarm| No AC output| Reduce the load
to related rang the inverter
will restart work, green light on, red light off.
Over temperature shut down| Green: on Red: on| ****
Alarm
| ****
No AC output
| When the inside temperature return to rela- ted rang, inverter will restart
work, green light on ,red light off.
Output short circuit| Green: on Red: on| Alarm| No AC output| When short
circuit stopped, inverter restart to work automatically.
VOLTAGE AND TEMPERATURE PERFORMANCE
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
- Transit damage.
- Normal wear of parts (eg. : cables, clamps, etc..).
- Damages due to misuse (power supply error, dropping of equipment, disassembling).
- Environment-related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc …)
- A description of the fault reported.
CHARACTERISTICS
SYMBOLS
- This product should be recycled appropriately.
RECOMMENDATIONS
GYS SAS
- 1, rue de la Croix des Landes CS 54159
- 53941 SAINT-BERTHEVIN Cedex
- www.gys.fr