SAMCON ExCam IPM2036 Explosion Proof Quad HD/ 4MP IP Came
Introduction
The ExCam IPM2036 is a powerful mega-pixel day-/night IP camera (4MP resolution) with advanced analysis (object classification). It is certified by ATEX, IECEx and EAC-Ex. The camera has a high-definition television resolution (2668×1512) and is equipped with integrated IR illumination. Besides this it has a Deep Learning Processor Unit for artificial intelligence with deep learning. The ExCam series is certified both in accordance with the European (ATEX) and international directive (IECEx). The explosion-protected housing is approved for ATEX group II for zones 1, 2, 21 and 22 including the explosion groups IIC / IIIC. To see other approvals, please visit our website at www.samcon.eu/en. When designing the ExCam IPM2036, we attached a very high importance to safety, mechanical precision and high- quality of stainless steel.
Technical data
Explosion protection
Illustration of the model key
Ex productname | Model variants | Options |
---|---|---|
1) | 2) Type | 3) Housing- combination |
Cable termin. | 7) Lens | |
ExCam IPM2036 | T08- | VA2.0.K1.BOR- |
T08- | VA2.0.K1.BOR- | LL.H- |
T08- | VA2.0.K1.BOR- | LL.H- |
T08- | VA2.0.K1.BOR- | LL.H- |
T08- | VA2.0.K1.BOR- | LL.HH- |
Explanations:
Model | Lens | Iris | Horizontal AoV@16/9 |
---|---|---|---|
T08-VA2.0.K1.BOR-X.X-XXX.X-X-085 (wide (standard)) | Megapixel lens 3.6mm | F1.8 | |
IR | 85° | ||
T08-VA2.0.K1.BOR-X.X-XXX.X-X-056 (normal) | Megapixel lens 6.0mm | F1.9 IR | 56° |
T08-VA2.0.K1.BOR-X.X-XXX.X-X-041 (tele) | Megapixel lens 8.0mm | F1.8 IR | 41° |
Electrical parameters of the camera
- Power supply of the camera via Ethernet (PoE):
- Voltage supply: PoE, IEEE 802.3af/802.3at type 1 class 3
- Reference voltage: +48 V DC (44…54 V DC)
- Maximum power consumption: 12.95 W
- Typical power consumption: 5.0 W
Connection cable Ex-d – Ex-e
- Description: Data transfer and power supply of the camera module (compliant with DIN EN 60079-14)
- Jacket colour: Green (GN), similar to RAL3001
Connection cable for models without cooling (SKD02-T/ASKD02-T)
- System cable SKD02-T:
- Outside diameter: 8.9 ± 0.3 mm
- Bending radius: 8 x Da when installed and 4 x Da after relocation
- Data line: 4 x 2 x AWG23/1 CAT.6
- Properties: PUR halogen-free, flame-retardant, UV-re-sistant, chemical resistance, shielded
Quick link:https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKD02-T_Datasheet.pdf
- System cable ASKD02-T:
- Outside diameter: 12.0 ± 0.4 mm
- Bending radius: 20 x Da when installed and 10 x Da after relocation
- Data line: 4 x 2 x AWG23/1 CAT.6
- Properties: PUR halogen-free, flame-retardant, UV-resistant, chemical resistance, shielded
Quicklink: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/ASKD02-T_Datasheet.pdf
Connection cable for model with cool.Jacket (SKD05-HT)
- Description: Data transfer and power supply of the camera module (compliant with DIN EN 60079-14)
- Jacket color: Grey (GY)
- System cable SKD05-HT:
- Outside diameter: 6.60 ± 0.2 mm
- Bending radius: 8 x Da when installed and 4 x Da after relocation
- Data line: 4 x 2 x AWG26/7 CAT.6
- Properties: FEP, flame-retardant, UV-resistant, chemical resistance, for extreme hot temperatures
Quick link: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKD05-HT_Datasheet.pdf
Video-technical characteristics
We use the AXIS M2036-LE Network Camera in a pressure-resistant enclosure. For
details, please refer to the Product Documentation, and video-technical data
of AXIS®:
https://www.axis.com/products/axis-m2036-le
Other technical data
Camera (Ex-d) | Terminal box (Ex-e) | |
---|---|---|
Permissible ambient temperature | -60°C … +60°C (PoE+ model LL.H) | -60°C … |
+55°C
Protection class as per EN 60529/IEC 529| IP66/68 (Test conditions: 24h/3m
water column 5°C)| IP66
Housing material| stainless steel, mat. no. 1.4404| polyester resin
Weight| about 5 kg| about 1 kg
Dimensions| D113mm x 161mm| 145mm x 145mm x 71mm
IR-LED illumination
When switching to night mode, the camera uses both visible and near-infrared
light to deliver bright and detailed black-and-white images instead of color
images.
2x high-efficiency LEDs3
IR-LEDs with optimized infrared spectral component (λcentroid = 850 [nm]),
enable high-contrast black and white camera images in the dark and under
difficult lighting conditions (max. distance in complete darkness 2m,
otherwise typical range depends on lighting con-ditions (residual light) and
Scene). See test protocol for illumination.
Attention! Infrared radiation may emanate from this product. Do not look
directly at the operating lamp.
Settings for automatic switching to night mode
- Set the IR-cut filter to Auto: go to Video > Image > Day-night mode
- Determination of the light level from which the camera should switch to night mode: move the Threshold slider towards Bright or Dark.
- To use the built-in IR light oft he camera, when the camera is in night mode: Activate Allow IR illumination and Synchronize IR illumination.
- Tip: Set the switch to night mode when it is brighter Image remains sharper, as there is less low-light noise. Set the switch to night mode when it is darker colors are maintained for longer, but there is more image blur due to low-light noise.
Optimize IR illumination
Depending on the positioning and conditions around the camera, such as
external light sources in the scene, IR illumination can sometimes be improved
by manually adjusting the intensity of the LEDs.
- Go to Video > Image > Day-night mode.
- Activate Allow illumination.
- Go to and select Manual.
- Adjust the intensity.
Illumination tests
Tests with IR illumination ON
In absolute darkness, the internal infrared illumination can only be used up to a maximum object distance of 2.0 m. In addition, the quality of the image is strongly influenced by the resulting reflections and the object to be observed is no longer visible. The image quality increases as soon as an external infrared light source is used. When illuminated by external infrared light, the distance to be observed is more than 30.0m and the image has no noticeable loss of quality due to the illumination. In absolute darkness, it is advisable to use an external infrared light source.
Safety Instructions
Please absolutely observe the installation instruction’s safety directions of
the T08 ExCam series!
Quick link: https://www.samcon.eu/fileadmin/documents/en/22-Ex-Network-
Cameras/ExCam-Series-T08-EX-Installation-Manual-2020.pdf
It is absolutely mandatory to adhere to the national safety regulations and regulations for the prevention of accidents, as well as to the safety instructions given below in this User Manual!
- Attention! Cameras of type T08 ExCam are not suitable for use in zones 0 and 20. The ambient temperature, temperature class and explosion group written on the enclosure nameplate must be absolutely adhered to! The customer is not allowed to make any alterations of the camera! The camera must be operated in a proper and sound condition and only in the way intended.
- Attention! Repairs may only be carried out by using original parts from the manu-facturer. Repairs that affect the explosion protection may only be carried out in accordance with the nationally applied regulations and exclusively by the manufacturer.
- Attention! Prior to installation, take external sources of heat or cold into account! The temperature ranges prescribed for storage, transport and operating must be adhered to!
- Attention! Adhere to the warnings given on the nameplate:
- “WARNING – DO NOT OPEN IN HAZARD AREAS“
- Using the camera in explosion-protected areas with regard to temperature and dust layers is defined in the respective national regulations.
- When installing the ExCam, adhere to the requirements of the EN/IEC 60079-14.
Installation
For commissioning and operating the camera, the relevant national regulations, as well as the generally accepted rules of technology shall prevail. Before mounting the camera, thoroughly check it for any transport damage, especially on the housing and cable. Installation, electrical connection and the first start must only be carried out by qualified specialists.
Work preparation:
- Attention! Prepare your work carefully and in accordance with the relevant regulations.
- Attention! Depending on the classification of hazard areas, it is imperative to obtain a work approval first! When you open the pressure-resistant enclosure under voltage, it is absolutely necessary to prevent potentially explosive atmosphere!
To ensure the best image quality delivered by the network camera, plan the installation site carefully (consider light conditions, object distance or size, angle and minimum object distance to the focus).
- Use appropriate tools and aids.
- When working, ensure a safe stand.
- Make sure that any static charge is avoided.
Attention! Please observe the national security, installation and
accident prevention regulations (e.g. DIN EN 60079-14) and the safety
instructions in this User Manual, as well as the ones in the Installation
Guidelines!
Attention! Adhere to the provisions of the IECEx, ATEX and EX
installation instructions for mounting and starting up!
The ExCam® IPM2036 consists of a flame-proof camera housing (Ex-d) and, optionally (models with a terminal box …-T), a terminal box of a high degree of safety (Ex-e). Both units are connected via a 5 m cable. Mount the camera according to the desired field of view. Install the terminal box so that a good accessibility is provided, in order to facilitate electrical connection.
Attention! Please pay attention to the national and local regulations for
mounting heavy loads. In case of doubt, take appropriate security measures.
Drawings for drill hole patterns and further information can be viewed on our
product page:
Quick link: https://www.samcon.eu/en/products/network/excam-ipm2036/
Optional mounting accessories
Electrical connection
- Attention! The electrical connection of the equipment may only be carried out by qualified and skilled personnel!
- Attention! It is absolutely necessary to ground the ExCam® series’ housing via the PA connection.
- Attention! Please observe the national security, installation and accident prevention regulations (e.g. DIN EN 60079-14) and the safety instructions in this User Manual, as well as the ones in the Installation Guidelines!
The delivered ExCam® IPM2036 is equipped with an electrical connection cable of type (A)SKD02-T (models without cooling) or type SKD05-HT (models with cool.Jacket). The maximum transmission range from the camera to the next active network interface is 100 meters (without cool.Jacket) or 60 meters (models L.HH) and can be individually specified by the client. The user is NOT authorised to do electrical connection procedures inside the pressure- resistant enclosure.
Potential equalization
Potential equalization/grounding of the camera housing is absolutely
necessary, in order to avoid static charges and thus the formation of sparks.
For this purpose, a screw terminal is provided at the rear side, at the bottom
(right) (see Figure 5-1). The cross-section of the potential equalization
should comply with the National Ground Rules (at least 4mm2).
Wiring table:
Potential| Colour (IEC 60757)| Cross- sec tion|
Comment
---|---|---|---
PA| GN/YE| 4 mm2 (rigid)| Terminal: Slotted screw M4x0.7 (DIN 84) with washer
Ø9mm (DIN 125A), Keep 3 Nm tightening torque!
Connection work at the device (terminal box) and fuses
- Power supply for the camera (PoE)
- Voltage supply: PoE, IEEE 802.3af/802.3at type 1 class 3
- Reference voltage: +48 V DC (44…54 V DC)
- Maximum power consumption: 12.95 W
- Typical power consumption: 5.0 W
The figures 5.2 and 5.3 illustrate the potential cable terminations of the ExCam IPM2036. Possible terminations are: terminal box or plug.
- Attention! Never open the Ex-e terminal box under voltage!
- Attention! Adhere to the international installation regulations for connection chambers with increased safety (Ex-e).
- Attention! Adhere to attached separate User Manual for the Exe terminal box.
Video Tutorial:
Observe our video tutorial: “SAMCON 01 Wiring the cable SKDP03-T to the
junction box ExTB-3” https://go.samcon.eu/v01
The pin assignment of the SKD02-T is executed in accordance with the standard EIA/TIA-568B as follows:
Camera (Ex-d)
(T568B)
| Colour SKD02-T
(IEC60757)
| Terminal ExTB-2| Cross-sec tional sur face| Comment
---|---|---|---|---
Tx+| WH / OG| 1| 0.26 mm2| Solid conductor
Tx-| OG| 2| 0.26 mm2| Solid conductor
Rx+| WH / GN| 3| 0.26 mm2| Solid conductor
Rx-| GN| 4| 0.26 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.26 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.26 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.26 mm2| Solid conductor
(PoE GND)| BN| 8| 0.26 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
The pin assignment of the ASKD02-T is executed in accordance with the standard EIA/TIA-568B as follows:
Camera (Ex-d)
(T568B)
| Colour ASKD02-T
(IEC60757)
| Terminal ExTB- 2/3| Cross-sec tional sur face|
Comment
---|---|---|---|---
Reinforcement| YE / GN| PE| 2.5 mm2| Flex
Tx+| WH / OG| 1| 0.26 mm2| Solid conductor
Tx-| OG| 2| 0.26 mm2| Solid conductor
Rx+| WH / GN| 3| 0.26 mm2| Solid conductor
Rx-| GN| 4| 0.26 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.26 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.26 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.26 mm2| Solid conductor
(PoE GND)| BN| 8| 0.26 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
The pin assignment of the SKD05-HT is executed in accordance with the standard EIA/TIA-568B as follows:
Camera (Ex-d)
(T568B)
| Colour SKD05-HT
(IEC60757)
| Terminal ExTB-2| Cross-sec tional sur face| Comment
---|---|---|---|---
Tx+| WH / OG| 1| 0.14 mm2| Solid conductor
Tx-| OG| 2| 0.14 mm2| Solid conductor
Rx+| WH / GN| 3| 0.14 mm2| Solid conductor
Rx-| GN| 4| 0.14 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.14 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.14 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.14 mm2| Solid conductor
(PoE GND)| BN| 8| 0.14 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
- Attention! Introduce the foiling up to about 15 mm close to the terminals, in order to prevent alien crosstalk. Make sure that the foiling cannot cause any short circuit of the data pairs!
- Attention! Bring the twisted pair composite up to about 10 mm close to the terminals, in order to ensure interference immunity.
- Attention! Use only terminals approved by SAMCON.
- Attention! Finally, check your network installation with a Class-D Link Test.
External connection and protection
There are several options of routing the ExTB-2/3 terminal box to a safe area:
Direct routing from the ExTB-3 into the safe area
In the case of direct routing from ExTB-2/3 to the safe area, the voltage
signal is led from the safe area to the terminal box. Please observe the
terminal box assignment, as described above.
- Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14.
- Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations.
Routing via ExConnection Rail (optional accessories)
In the case of routing the ExTB-2/3 into an ExConnection Rail, larger
installation distances can be managed.
Note: In hazardous areas, the ExConnection Rail (optional accessories)
acts as a PoE+ switch, a media converter from copper to fiber-optic cable, as
well as a power supply for the cameras.
Appropriate cables & cable entries
An integral part of the device safety is the correct selection of the cables,
wires and cable entries.
- Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14.
- Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations.
For non-binding configuration and planning guidelines, please visit our website:
Perhaps our video will help you: “Cables for flameproof devices in potentially explosive atmospheres” http://go.samcon.eu/video-cable-ex
Particularly for installations requiring a suitable barrier gland, make sure that you handle them correctly and observe the rules and notes given in the respective mounting and as-sembly instructions.
We show the essential procedures in the following video tutorial:
Video Tutorial:
Please note our video tutorial: “SAMCON 02 Mounting and installing Ex-d
barrier glands to ExConnection Rails” https://go.samcon.eu/v02
Fusing
PoE power supply requires no fuses. The power supply fusing depends on the
cable cross-section and length.
Attention! Please pay attention to the national and international
regulations regarding selectivity and line protection.
Plug assignments (RJ45)
The data transfer of the ExCam IPM2036 uses a 100 Mbit/s Ethernet connection
(100BASE-TX). If the cable termination uses a plug, the latter should be
plugged into the RJ45 PoE slot of the network device (PSE). Prior to
connecting it to the camera, the network device (PSE) can already be supplied
with power, hence there is no „power ON“ priority that has to be observed.
- Attention! Use appropriate RJ45 plugs! Check the cable shielding, cross-section and the outside diameter!
- Attention! It is imperative to ensure a correct routing of the individual wires according to the EIA/TIA-568B”
- Attention! Finally, check your network installation with a Class-D Link Test.
Detailed instructions on how to connect a RJ45 plug are available in our video tutorial: “SAMCON 03 Mounting and installing the RJ45 jack to SAMCON cables” https://go.samcon.eu/v03
Tests prior to switching on voltage
- Attention! Prior to starting the device, perform all tests as indicated by the national regulations. Furthermore, check the correct function and installation of the device in accordance with this User Manual and other applicable regulations.
- Attention! Incorrect installation or operation of the camera may lead to a loss of warranty!
- Attention! Do not switch on the camera at temperatures below 0°C!
Working inside the camera housing (Ex-d)
The customer may open the housing only if it is absolutely necessary. Only exchanging the SD memory card or a hardware reset are reasons for this.
Preparation for work:
- Attention! Prepare your work carefully and in accordance with the relevant regulations.
- Attention! Depending on classification of hazard areas, it is imperative to obtain a work approval first!
If you adjust the camera yourself or open the pressure-resistant enclo-sure (Ex-d) under voltage, it is absolutely imperative to prevent poten-tially explosive atmosphere!
Opening the pressure-resistant housing
-
WARNING – MAY NOT BE OPENED IN HAZARD AREAS
-
Note: Depending on classification of hazard areas, it is imperative to obtain a work approval first!
Even after switching on the power supply, it is absolutely imperative to avoid potentially explosive atmosphere when opening the camera housing. Opening the housing requires disassembly and working in a safe (i.e. non-explosive!) area. -
Attention! Pay attention not to damage the thread surface of the flame-proof gap.
-
Attention! Pay attention not to damage the housing seals. Keep them clean!
If the ExCam IPM2036 is equipped with a weather protection roof this has to be removed prior to starting your work! To do so, loosen the 4x12mm button head screws M4*0.7 at the front and rear sides of the bracket holders (Figure 6-1).
To open the stainless-steel housing (T07 VA2.0.x.x) of ExCam IPM2036, loosen the eight cylinder-head hexagon screws (DIN 912/ ISO 4762) together with their spring rings (DIN 127A) on the rear side of the cable and power supply flange (see Figure 6-2). Caution: do not touch the screw threads with your skin or clothes! On the threads, there is LOCTITE® 243™ (chemical basis is methacrylate ester) applied to prevent the bolted connection from unintentional loosening because of impacts and vibrations and to seal them tightly. It is not permitted for the customer to open the front-side sight glass flange! There is no need of such an action.
Carefully pull out the cable and supply flange to the rear, as straight as possible. Because of negative pressure, it may be difficult to remove the flange. The cylindrical clearance fit (H8f7 – DIN ISO 286) of the camera body and flange may not be tilted! Risk of damage to the flame-proof gap (DIN EN 60079-1:2012)!
Attention: The mounting adapter with the housing’s PTC heater, camera
module and optics, as well as the temperature control, and (if applicable)
auxiliary relays and terminal block are fixed on the cable and supply flange.
Dealing with these components, too, you have to work very carefully and
precisely in order to avoid canting and damage to the in-built components!
Caution: do not touch the cylindrical fit surface with your skin or clothes!
On the surface, there is oil lubricating paste to protect the surface against
fretting corrosion and mechanical stresses.
When you open the housing, pay attention that you do not damage the GYLON®
flat seal (blue, RAL5012) and do not make it dirty! The flat gasket is loosely
attached to the cable and power supply flange. It is fixed only by the bolted
connections!
- Attention! Pay attention not to damage the surface of the drill hole and the shaft (fitting) of the flame-proof gap.
- Attention! Pay attention not to damage the housing seals. Keep them clean!
Removing/inserting a SD memory card
Note: The ExCam IPM2036 has a slot for a micro SDHC memory card (card
not included). Saved video files can be played and deleted via the web
interface. They are also available in a download list. Moreover, the videos
available in the memory card can also be accessed via FTP server in the
network. If the memory card has to be replaced by the user, it should be, as
far as possible, empty and pre-formatted with an ext4 or vFAT file system.
When touching electrical components, observe potential equalization (grounding of the body): carry electrostatic-discharge clothes, a PE wristband etc.!
Hardware Reset
To set all the parameters of the ExCam IPM2036 (including the IP address) to
default values, you should run a hardware reset. The parameters can be reset
via the web interface or manually. If the camera placed in the network can no
longer be reached or its state is uncontrollable, the reset should be
performed manually. To do so, proceed as follows:
- Disconnect the camera installation module (Axis M2036-LE) from the power supply.
- Press and hold the control button (see the illustration below) and, at the same time, connect the system to the voltage supply (PoE).
- Hold the control button pressed for about 30 seconds.
- Release the control button. After about a minute, the AXIS M2036-LE will return to factory defaults. If there is a DHCP server in the network, the IP address will be the following: 192.168.0.90 (subnet masking 255.255.255.0).
- IP address and password can be redefined. If the hardware reset is not satisfactory or the network camera shows serious conflicts or does not work as usual (errors in the browser visualisation, frozen images, control commands no longer processed, slowing down of the system, etc.), it may be necessary to re-install the current firmware, or to install an update (see Chapter 7).
Closing of the pressure-resistant housing
For closing the housing, proceed in reverse order as when opening. Use
exclusively original screws included in the supply. The cable and power-supply
flange (K1) is fixed by 8 cylinder-head screws M4*0.7 (ISO metric right-
turning) with 12 mm thread length (DIN 912/ ISO 4762, grade 6g). Materials of
bolted connections are identical to the pressure-resistant stainless steel
housing (standard material no. 1.4404 AISI316L). Check whether the threaded
holes are undamaged and clean. Before closing, it is also absolutely
imperative to check the flame-proof gap (circular cylindrical fit).
- Attention! If any mechanical damages occurred to the fitting gap, it is no longer allowed to use the housing!
- Attention! Do not lock-in any foreign objects in the housing.
Dismantled screw locks (spring washers DIN 127A) must be used again. The
GYLON® gasket must be used in undamaged condition, according to the flange
hole pattern, and placed between the flange and the hull. The lateral position
of the flat surface/contact surface is arbitrary. If, when closing the
housing, you see that the surface of the fitting gap is dirty or
insufficiently lubricated, clean it with a clean cloth and de-grease it with a
suitable cleaning agent. Then re-grease it with lubricant suitable for this
specific application (e.g., Molykote® P-40 gel for standard applications or
special grease OKS 403 in the event of heavy seawater influence).
The screwed connections of flange and body components must always be tightened
cross-wise to a torque of 3 Nm! Do not tighten the screw too strongly! It can
cause rupture of the cylinder head or over-stretching the threads, and thus to
impairment of the pressure resistance or ignition protection class Cylinder-
head bolts for explosion-proof connection of the camera body with the flange
component must always be tightened at a 3 Nm torque-crosswise and evenly! Use
Loctite.
Network access and visualization
The most important procedures of the first starting up the camera are described below. The configuration menu of the web surface allows intuitive navigation and offers several configuration possibilities. For detailed documentation and information how to use the web Interface, please see the User Manual for Axis or visit the following website:
- https://help.axis.com/axis-m2036-le
- https://help.axis.com/api/download/um_m20_bullet_camera_se-ries_t10175189_de_2204.pdf
The delivered ExCam IPM2036 is set to the applicable net frequency (50Hz or 60Hz). If the camera is used at a location with a differing net frequency, the image might start to flicker, particularly in surroundings with fluorescent tubes. In such a case, the applicable settings have to be carried out inside the menu “System Options > Advanced > Plain Con-fig”.
- User: root
- Password: root
Browser Support
A list of the currently supported web browsers, operating systems, required
add-ons, etc. can be viewed at:
Assigning the IP address
The ExCam IPM2036 is intended for use in an Ethernet network and requires an
IP address to access and control it. In most today’s networks, a DHCP server
is integrated. This server automatically assigns an IP address. If there is no
DHCP server available in the network, the IP default address of ExCam IPM2036
is “192.168.0.90” (subnet masking 255.255.255.0). With the “AXIS IP Utility”,
it is possible to determine the IP address under Windows; the included USB
stick contains this application.
https://www.axis.com/support/tools/axis-ip-utility
If it is not possible to assign the IP address, it might be necessary to
change the firewall settings!
The “AXIS IP Utility“ tool automatically recognizes all ExCam devices and
visualises them in the device list. It can also be used to manually assign a
static IP address. For this purpose, the ExCam IPM2036 network camera has to
be installed in the same physical network segment (physical subnet) as the
computer on which the AXIS IP Utility is running. The network signature of
ExCam IPM2036 is “AXIS M2036-LE” (see Figure 7-1). MAC address and serial
number for clear device identification are also detected and displayed
.
Password/ Identification
- The following user name is set at the factory: root
- The following password is set at the factory: root
Maintenance / Modification
The applicable regulations for the maintenance and servicing of electrical
devices in potentially explosive atmospheres must be adhered to.
The required maintenance intervals are specific to the individual devices. The
operating company has to determine these intervals depending on the
application parameters. The maintenance tasks especially include examination
of parts on which the ignition protection depends (e.g., proper condition of
the casing, seals and cable entry points). If maintenance measures are
necessary they have to be initiated and/or executed.
Repairs may only be carried out with original parts of SAMCON Prozessleittechnik GmbH. Damaged pressure-resistant housings have to be replaced completely. In case of doubt, send the part in question back to SAMCON Prozessleittechnik GmbH. Reparations concerning the explosion protection must only be carried out in accordance with nationally applied regulations by SAMCON Prozessleittechnik GmbH or by an authorised electrical technician authorised by SAMCON Prozessleittechnik GmbH. Rebuilding of or alterations to the devices are not permitted.
Disposal / Recycling
When disposing of the device, nationally applicable regulations must be observed. This Document is subject to alterations and additions.
Drawings & 3D models
All drawings, 3D models, certificates and other information are available in
the download area of the product page on our website:
https://www.samcon.eu/en/products/network/excam-ipm2036/
If you wish additional technical information, please contact us at: support@samcon.eu
Certificates and further documentation are available in the download area at the product website: https://www.samcon.eu/en/products/network/excam-ipm2036
History of revisions
- Product: ExCam® IPM2036
- Title: User Manual for ExCam® IPM2036
- Doc. -Id. 220607-PT08BA-ES-ExCam IPM2036_en_rev.02.docx
- Author: Eva Schneider, Grad. Eng. (UAS)
- Created on: 07.06.2022
Rev. Index| Date| Name| Comment| Approved by the
ATEX Supervisor
---|---|---|---|---
0| 07.06.2022| E. Schneider| Compilation of the document|
1| 21.11.2022| E. Schneider| Change of housing to VA2.0|
2| 18.01.2023| E. Schneider| Change of EACEx-Certificate| Sebastian Weber
2023.01.18 12:01:51 +01’00’
Schillerstrasse 17, 35102 Lohra-Altenvers, Germany
www.samcon.eu
info@samcon.eu
Phone: +49 6426 9231-0
fax: – 31
References
- YouTube
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- YouTube
- YouTube
- YouTube
- How to assign an IP address and access your device User manual
- AXIS M2036-LE Bullet Camera User manual
- AXIS M2036-LE Bullet Camera | Axis Communications
- Welcome to Axis support | Axis Communications
- AXIS IP Utility | Axis Communications
- ExCam IPM2036- Explosion Proof Quad HD/ 4MP IP Camera with IR illumination, ATEX, IECEx, EAC-Ex & IP66, IP68
- ExCam IPM2036- Explosion Proof Quad HD/ 4MP IP Camera with IR illumination, ATEX, IECEx, EAC-Ex & IP66, IP68
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>