SAMCON Rough Cam IPM 2036 IP Camera User Manual
- June 9, 2024
- SAMCON
Table of Contents
Rough Cam IPM 2036 IP Camera
RoughCam® IPM2036
User Manual
Table of contents 1 Introduction ……………………………………………………………………………………………….. 4 2
Technical data ……………………………………………………………………………………………. 4
2.1 Illustration of the model key………………………………………………………………………4 2.2 Electrical
parameters of the camera…………………………………………………………..6 2.3 Connection
cable……………………………………………………………………………………. 6
2.3.1 Connection cable for models without cooling
(SKD01-T/ASKD02-T)…………………………………. 6 2.3.2 Connection cable for model with
cool.Jacket (SKD05-HT) ………………………………………………. 7
2.4 Video-technical characteristics …………………………………………………………………. 8 2.5 Other
technical data ……………………………………………………………………………….. 8 2.6 IR-LED
illumination………………………………………………………………………………….8
2.6.1 Settings for automatic switching to night mode ……………………………………………………………….
9 2.6.2 Optimize IR illumination ………………………………………………………………………………………………. 9 2.6.3
Illumination tests ………………………………………………………………………………………………………. 10
3 Safety Instructions ……………………………………………………………………………………. 11 4 Installation
……………………………………………………………………………………………….. 11 5 Electrical connection
………………………………………………………………………………… 13
5.1 Potential equalization ……………………………………………………………………………. 13 5.2 Connection
work at the device (terminal box) and fuses …………………………….. 14
5.2.1 Fusing …………………………………………………………………………………………………………………….. 18 5.2.2 Plug
assignments (RJ45)…………………………………………………………………………………………… 19 5.2.3 Tests prior to
switching on voltage ……………………………………………………………………………… 20
6 Working inside the camera housing …………………………………………………………… 21 6.1 Preparation
for work: …………………………………………………………………………….. 21 6.2 Opening the housing
…………………………………………………………………………….. 21 6.3 Removing / inserting a SD memory card
………………………………………………….. 23 6.4 Hardware Reset ……………………………………………………………………………………
23 6.5 Closing of the pressure-resistant housing ………………………………………………… 24
7 Network access and visualization ……………………………………………………………… 25 7.1 Browser
Support…………………………………………………………………………………… 25 7.2 Assigning the IP
address………………………………………………………………………..25 7.3 Password/ Identification
………………………………………………………………………… 26
8 Maintenance / Modification…………………………………………………………………………26 9 Disposal /
Recycling …………………………………………………………………………………. 27 10 Drawings, 3D models,
certificates & further documentation …………………….. 27
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 2 of 28
Table of Figures and Charts
Table 2-1 Model key ……………………………………………………………………………………………. 4 Figure 2-1
Sectional view of SKD01-T…………………………………………………………………….6 Figure 2-2 Sectional
view of ASKD02-T ………………………………………………………………….7 Figure 2-3 Sectional view of
SKD05-HT ………………………………………………………………….7 Table 2-2 Other technical data
……………………………………………………………………………… 8 Figure 2-4 IR LEDs
……………………………………………………………………………………………… 9 Table 4-1 Mounting accessories
………………………………………………………………………….. 12 Figure 5-1 RoughCam IPM2036 Potential
equalization …………………………………………… 13 Table 5-1 Potential equalization
………………………………………………………………………….. 14 Figure 5-2 RoughCam IPM2036 T10-VA2.0.K1
.BOR-LL.H-xxx.N-T …………………………. 14 Figure 5-3 RoughCam IPM2036 T10-VA2.0.K1.BOR-
LL.H-xxx.N-P …………………………. 14 Figure 5-4 RoughCam IPM2036 T10-VA2.0.K1.BOR-
LL.HH-010.N-T ………………………. 15 Figure 5-5 Video Tutorial ExTB-3
………………………………………………………………………… 15 Table 5-2. Wire assignment of terminal box
ExTB-2 ……………………………………………….15 Table 5-3 Wire assignment of terminal box
ExTB-2/3 (ASKD02-T) ……………………………16 Figure 5-6 Sample circuit of terminal box
ExTB-2 ………………………………………………….. 16 Figure 5.7 Connection to the terminal box
………………………………………………………….. 17 Table 5-4 Wire assignment of terminal box ExTB-2
(SKD05-HT)………………………………18 Figure 5-8 Plug assignment, RJ45
………………………………………………………………………. 19 Figure 6-1 Removing the weather protection
roof……………………………………………………21 Figure 6-2 Opening the RoughCam IPM2036 (similar
illustration)……………………………..22 Figure 6-3 Structure of the camera
………………………………………………………………………. 22 Figure 7-1 Axis IP Utility
…………………………………………………………………………………….. 26
History of revisions
Product: Title: Doc. -Id. Author: Created on:
RoughCam® IPM2036 User Manual for RoughCam® IPM2036 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx Eva Schneider, Grad. Eng. (UAS) 15.08.2022
Rev. Index 0
1
Date
Name
Comment
15.08.2022 E. Schneider Compilation of the document
15.12.2022 E. Schneider Change of housing to VA2.0
Approved by
Sebastian Weber 2022.12.15 11:50:34 +01’00’
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 3 of 28
1 Introduction
The RoughCam IPM2036 is a powerful mega-pixel day-/night IP camera (4MP
resolution) with advanced analysis (object classification). The camera has a
high-definition television resolution (2668×1512) and is equipped with
integrated IR-illumination. Besides this it has a Deep Learning Processor Unit
for artificial intelligence with deep learning. The RoughCam series is
suitable for indoor as well as outdoor applications. It is extremely robust
and therefore perfect for even the roughest industrial conditions. The
stainless steel housing allows additional alloys, a powder coating, or coats
of varnishes as well as various mechanical accessories in order to extend the
resistance towards extreme environmental conditions (salt water, acid, solar
radiation, high mechanical strains etc.). Due to the usage of high-quality
PTFE sealings, not only the protection level IP68 is reached but also the
chemical resistance is maximized. To see other approvals, please visit our
website at www.samcon.eu/en When designing the RoughCam IPM2036, we attached a
very high importance to mechanical precision and high quality of stainless
steel.
2 Technical data
2.1 Illustration of the model key
Productname
Model variants
-
RoughCam IPM2036
-
Type
T10T10T10T10T10- -
Housingcombination
VA2.0.K1.BORVA2.0.K1.BORVA2.0.K1.BORVA2.0.K1.BORVA2.0.K1.BOR- -
Temp.range LL.HLL.HLL.HLL.HLL.HH-
-
Cable length [m] 005.N005.N005.A005.A010.N-
-
Cable termin.
PTPTT-
Options
7) Lens
085/056/041 085/056/041 085/056/041 085/056/041 085/056/041
Table 2-1 Model key
Explanations:
RoughCam IPM2036 = Functional camera description of the RoughCam Series (technical data/
specification of the individual camera module)
T10 =
SAMCON Production- Type 10 (for safe areas)
VA2.0.K1.BOR =
VA2.0.K1.BOR = VA2.0.K1.BOR = VA2.0.K1.BOR =
T11 housing (stainless steel 1.4404) with large diameter ØVA2=113mm) T11 VA2.0 housing with medium body length (L.R = 161mm) K1 cable gland flange Borosilicate sight glass DIN7080 (standard, for video cameras within visible spectral range: = 350…2000 [nm] and photografical infrared range (NIR), not suitable for thermographic applications (MIR/ FIR)
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 4 of 28
LL.H=
LL.H=
LL.HH=
005.N =
005.N = 005.A =
High temperature battery installed (Tamb < +60°C) Heater installed (Tamb >
-60°C) Active cooling with cool.Jacket for extreme high temperatures (-50°C <
Tamb < +120°C)
Length of the connection line in meter at delivery; 5m is the standard cable
length, max. cable length is: 005…100 [m] Non armoured cable Armoured cable
P =
T =
Lens options
Plug- termination (standard) CAT6, RJ-45 network plug (heavy duty), AWG 26-22,
contact assignment acc. To specification EIA/TIA-568B
Terminal Box termination (optional) 4 x PoE Mode A connection (camera PoE)
(see chapter electrical connection)
Model
Lens
T10-VA2.0.K1.BOR-X.X-XXX.X-X-085 (wide (standard)) T10-VA2.0.K1.BOR-X.X-XXX.X-X-056 (normal) T10-VA2.0.K1.BOR-X.X-XXX.X-X-041 (tele)
Megapixel lens 3.6mm Megapixel lens 6.0mm Megapixel lens 8.0mm
Iris
F1.8 IR F1.9 IR F1.8 IR
Horizontal AoV@16/9 85° 56° 41°
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 5 of 28
2.2 Electrical parameters of the camera
Power supply of the camera via Ethernet (PoE):
Voltage supply:
PoE, IEEE 802.3af/802.3at type 1 class 3
Reference voltage:
+48 V DC (44…54 V DC)
Maximum power consumption:
12.95 W
Typical power consumption:
5.0 W
2.3 Connection cable Description: Jacket colour:
Data transfer and power supply of the camera module (compliant with DIN EN 60079-14) Green (GN), similar to RAL3001
2.3.1 Connection cable for models without cooling (SKD01-T/ASKD02-T)
Systemcable SKD01-T: Outside diameter: Bending radius: Data line: Properties:
9.1 ± 0.2 mm 10 x Da when installed, 5 x Da after relocation 4 x 2 x AWG22/1 CAT.6 PUR halogen-free, flame-retardant, UV-resistant, chemical resistance, shielded
Figure 2-1 Sectional view of SKD01-T
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 6 of 28
System cable ASKD02-T: Outside diameter:
12.0 ± 0.4 mm
Bending radius:
20 x Da when installed and
10 x Da after relocation
Data line:
4 x 2 x AWG23/1 CAT.6
Properties:
PUR halogen-free, flame-retardant, UV-re-
sistant, chemical resistance, shielded
(see www.samcon.eu)
Quicklink:
https://www.samcon.eu/fileadmin/documents/en/60- Assembling%26mounting/ASKD02-T_Datasheet.pdf
Figure 2-2 Sectional view of ASKD02-T
2.3.2 Connection cable for model with cool.Jacket (SKD05-HT)
Description: Jacket colour:
Data transfer and power supply of the camera module (compliant with DIN EN 60079-14) Grey (GY)
Systemcable SKD05-HT:
Outside diameter:
6.60 ± 0.2 mm
Bending radius:
8 x Da when installed and 4 x Da after relocation
Data line:
4 x 2 x AWG26/7 CAT.6
Properties:
FEP, flame-retardant, UV-resistant, chemical
resistance, for extreme hot temperatures
Quick link:
https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKD05-HT_Datasheet.pdf
Figure 2-3 Sectional view of SKD05-HT
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 7 of 28
2.4 Video-technical characteristics
We use the AXIS M2036-LE Network Camera in a pressure-resistant enclosure. For
details, please refer to the Product Documentation, video-technical data of
AXIS®:
https://www.axis.com/products/axis-m2036-le
2.5 Other technical data
Protection class:
Transport/storage temperature: Ambient temperature:
IP 66/68 (IEC /EN 60529)
-40°C…+65°C (non-condensing) -60°C…+60°C (Type…LL.H…) -50°C…+120°C (Type…LL.HH) 1
Permissible ambient temperature
Protection class as per EN 60529/IEC 529
Housing material Weight Dimensions
Camera
-60°C … +60°C (PoE power supply model LL.H) IP66/68 (Test conditions: 24h/3m water column 5°C) stainless steel, mat. no. 1.4404 about 5 kg D113mm x 161mm
Terminal box (Ex-e)
-60°C … +55°C
IP66
polyester resin about 1 kg 145mm x 145mm x 71mm
Table 2-2 Other technical data
2.6 IR-LED illumination
When switching to night mode, the camera uses both visible and near-infrared
light to deliver bright and detailed black and white images instead of color
images.
2x high efficiency LEDs2 IR-LEDs with optimized infrared spectral component
(centroid = 850 [nm]), enable highcontrast black and white camera images in
the dark and under difficult lighting conditions (max. distance in complete
darkness 2m, otherwise typical range depends on lighting conditions (residual
light) and Scene). See test protocol for illumination.
Attention! Infrared radiation may emanate from this product. Do not look
directly at the operating lamp.
1 This model requires the SAMCON cool.Jacket. 2 In the case of IR LED
illumination, the viewing angle may be minimally restricted or a
shadow/reflection may be visible, depending on the lens, the adjustment of the
illumination angle and the residual light. Image disturbances possible due to
multiple LED light reflections on the borosilicate sight glass of the
stainless steel housing.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 8 of 28
Figure 2-4 IR LEDs
2.6.1 Settings for automatic switching to night mode
1. Set the IR-cut filter to Auto: go to Video > Image > Day-night mode 2.
Determination of the light level from which the camera should switch to night
mode: move the Thresold slider towards Bright or Dark. 3. To use the built-in
IR light oft he camera, when the camera is in night mode: Activate
Allow IR illumination and Synchronize IR illumination. 4. Tip:
Set the switch to night mode when it is brighter Image remains sharper, as
there is less low-light noise. Set the switch to night mode when it is darker
colors are maintained for longer, but there is more image blur due to low-
light noise.
2.6.2 Optimize IR illumination
Depending on the positioning and conditions around the camera, such as
external light sources in the scene, IR illumination can sometimes be improved
by manually adjusting the intensity of the LEDs.
1. Go to Video > Image > Day-night mode. 2. Activate Allow illumination. 3.
Go to and select Manual. 4. Adjust the intensity.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 9 of 28
2.6.3 Illumination tests
Tests with IR illumination ON
85°
56°
41°
With low
light
Object
distance
0.5m
Darkness Object distance 0.5m
Darkness Object distance 1m
Darkness Object distance 2m
Darkness Object distance 5m
In absolute darkness, the internal infrared illumination can only be used up to a maximum object distance of 2.0 m. In addition, the quality of the image is strongly influenced by the resulting reflections and the object to be observed is no longer visible. The image quality increases as soon as an external infrared light source is used. When illuminated by external infrared light, the distance to be observed is more than 30.0m and the image has no noticeable loss of quality due to the illumination. In absolute darkness, it is advisable to use an external infrared light source.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 10 of 28
3 Safety Instructions
Please observe the national safety regulations and regulations for prevention
of accidents, as well as to the safety instructions given below in this User
Manual!
Attention! Repairs may only be carried out by using original parts from the
manufacturer. Repairs may only be carried out in accordance with the
nationally applied regulations and exclusively by the manufacturer.
Attention! Prior to installation, take external sources of heat or cold into
account! The temperature ranges prescribed for storage, transport and
operating must be adhered to!
4 Installation
For commissioning and operating the camera, the relevant national regulations,
as well as the generally accepted rules of technology shall prevail. Before
mounting the camera, thoroughly check it for any transport damage, especially
on the housing and cable. Installation, electrical connection and the first
start must only be carried out by qualified specialists.
Work preparation:
Attention! Prepare your work carefully and in accordance with the relevant
regulations.
To ensure the best image quality delivered by the network camera, plan the
installation site carefully (consider light conditions, object distance or
size, angle and minimum object distance to the focus).
Use appropriate tools and aids. When working, ensure a safe stand. Make sure
that any static charge is avoided.
Attention! Please observe the national security, installation and accident
prevention regulations and the safety instructions in this User Manual!
The RoughCam® IPM2036 consists of a camera housing and, optionally (models
with a terminal box …-T), a terminal box. Both units are connected via a 5 m
cable. Mount the
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 11 of 28
camera according to the desired field of view. Install the terminal box so
that a good accessibility is provided, in order to facilitate electrical
connection.
Attention! Please pay attention to the national and local regulations for
mounting heavy loads. In case of doubt, take appropriate security measures.
Drawings for drill hole patterns and further information can be viewed on our
product page:
Quick link: https://www.samcon.eu/en/products/roughcam/roughcam-ipm2036/
Optional mounting accessories Wall bracket WMB-…
Weather protection roof WPR-…
Pole adapter PMB-…
WALL MOUNT WMB-VA2.0-2.2 Wall bracket for cameras of the T10-VA2.0-Series
Suitable for hanging the cameras on walls. Material: Stainless steel 1.4404
Load bearing: 25 kg Dimensions: 80 x 100 x 275 mm
WEATHER PROTECTION ROOF WPR-VA2.0 Weathershield for cameras of the
T10-VA2.0Series
WALL MOUNT BRACKET PMB-VA2.0 Pole adapter for VA wall mount Material:
stainless steel 1.4404 Suitable for pole diameters between 50 and 100 mm Load-
bearing capacity: 50 kg Dimensions:120 x 180 (x 130 bei Mast Ø 60 mm)
Table 4-1 Mounting accessories
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 12 of 28
5 Electrical connection
Attention! The electrical connection of the equipment may only be carried out
by qualified and skilled personnel!
Attention! It is absolutely necessary to ground the RoughCam® series’ housing
via the PA connection.
The delivered RoughCam® IPM2036 is equipped with an electrical connection
cable of the type SKD01-T/ASKD02-T (models without cooling) or type SKD05-HT
(models with cool.Jacket). The maximum transmission range from the camera to
the next active network interface is 100 meters (without cool.Jacket) or 60
meters (models L.HH) and can be individually specified by the client. The user
is NOT authorised to do electrical connection procedures inside the enclosure.
5.1 Potential equalization
Figure 5-1 RoughCam IPM2036 Potential equalization
Potential equalization/grounding of the camera housing is absolutely
necessary, in order to avoid static charges and thus the formation of sparks.
For this purpose, a screw terminal is provided at the rear side, at the bottom
(right) (see Figure 5-1). The cross-section of the potential equalization
should comply with the National Ground Rules (at least 4mm2).
Wiring table:
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 13 of 28
Potential PA
Colour (IEC 60757) GN/YE
Cross-section 4 mm2 (rigid)
Comment
Terminal: Slotted screw M4x0.7 (DIN 84) with washer Ø9mm (DIN 125A), Keep 3 Nm
tightening torque!
Table 5-1 Potential equalization
5.2 Connection work at the device (terminal box) and fuses
Power supply for the camera (PoE) Voltage supply: Reference voltage: Maximum power consumption: Typical power consumption:
PoE, IEEE 802.3af/802.3at type 1 class 3 +48 V DC (44…54 V DC) 12.95 W 5.0 W
The figures 5.2 and 5.3 illustrate the potential cable terminations of the RoughCam IPM2036. Possible terminations are: terminal box or plug.
Figure 5-2 RoughCam IPM2036 T10-VA2.0.K1.BOR-LL.H-xxx.N-T
Figure 5-3 RoughCam IPM2036 T10-VA2.0.K1.BOR-LL.H-xxx.N-P
Figure 5.4 shows RoughCam IPM2036 with active cooling cool.Jacket.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 14 of 28
Figure 5-4 RoughCam IPM2036 T10-VA2.0.K1.BOR-LL.HH-010.N-T
Video Tutorial: Observe our video tutorial: “SAMCON 01 Wiring the cable
SKDP03-T to the junction box ExTB-3″ https://go.samcon.eu/v01
Figure 5-5 Video Tutorial ExTB-3
The pin assignment of the SKD01-T is executed in accordance with the standard EIA/TIA-
568B as follows:
Camera
Colour
Terminal
Cross-sec- Comment
(T568B)
SKD01-T
Box
tional sur-
(IEC60757)
face
Tx+
WH / OG
1
0.32 mm2
Solid conductor
Tx-
OG
2
0.32 mm2
Solid conductor
Rx+
WH / GN
3
0.32 mm2
Solid conductor
Rx-
GN
4
0.32 mm2
Solid conductor
(PoE +48 VDC)
WH / BU
5
0.32 mm2
Solid conductor
(PoE +48 VDC)
BU
6
0.32 mm2
Solid conductor
(PoE GND)
WH / BN
7
0.32 mm2
Solid conductor
(PoE GND)
BN
8
0.32 mm2
Solid conductor
GND/SHD
YE / GN
PE
2.5 mm2
Flex
Table 5-2. Wire assignment of terminal box ExTB-2
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 15 of 28
The pin assignment of the ASKD02-T is executed in accordance with the standard EIA/TIA-
568B as follows:
Camera
Colour
Terminal
Cross-sec- Comment
(T568B)
ASKD02-T
Box
tional sur-
(IEC60757)
face
Reinforcement YE / GN
PE
2.5 mm2
Flex
Tx+
WH / OG
1
0.26 mm2
Solid conductor
Tx-
OG
2
0.26 mm2
Solid conductor
Rx+
WH / GN
3
0.26 mm2
Solid conductor
Rx-
GN
4
0.26 mm2
Solid conductor
(PoE +48 VDC)
WH / BU
5
0.26 mm2
Solid conductor
(PoE +48 VDC)
BU
6
0.26 mm2
Solid conductor
(PoE GND)
WH / BN
7
0.26 mm2
Solid conductor
(PoE GND)
BN
8
0.26 mm2
Solid conductor
GND/SHD
YE / GN
PE
2.5 mm2
Flex
Table 5-3 Wire assignment of terminal box ExTB-2/3 (ASKD02-T)
SKD02-T
RoughCam IPM2036
SKD02-T
Figure 5-6 Sample circuit of terminal box ExTB-2
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 16 of 28
PoE 802.3af 100 BASE TX Ethernet
Figure 5.7 Connection to the terminal box
Attention! Introduce the foiling up to about 15 mm close to the terminals, in
order to prevent alien crosstalk. Make sure that the foiling cannot cause any
short circuit of the data pairs! Attention! Bring the twisted pair composite
up to about 10 mm close to the terminals, in order to ensure interference
immunity. Attention! Use only terminals approved by SAMCON. Attention!
Finally, check your network installation with a Class-D Link Test. Note: If
the camera is equipped with a camera cooling system (SAMCON cool.Jacket for
model key type X.HH), the wiring is executed via the cable SKD05-HT. An
appropriate water supply has to be provided by the customer.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 17 of 28
The pin assignment of the SKD05-HT is executed in accordance with the standard EIA/TIA-
568B as follows:
Camera
Colour
Terminal
Cross-sec- Comment
(T568B)
SKD05-HT
Box
tional sur-
(IEC60757)
face
Tx+
WH / OG
1
0.14 mm2
Solid conductor
Tx-
OG
2
0.14 mm2
Solid conductor
Rx+
WH / GN
3
0.14 mm2
Solid conductor
Rx-
GN
4
0.14 mm2
Solid conductor
(PoE +48 VDC)
WH / BU
5
0.14 mm2
Solid conductor
(PoE +48 VDC)
BU
6
0.14 mm2
Solid conductor
(PoE GND)
WH / BN
7
0.14 mm2
Solid conductor
(PoE GND)
BN
8
0.14 mm2
Solid conductor
GND/SHD
YE / GN
PE
2.5 mm2
Flex
Table 5-4 Wire assignment of terminal box ExTB-2 (SKD05-HT)
5.2.1 Fusing
PoE power supply requires no fuses. The power supply fusing depends on the
cable crosssection and length.
Attention! Please pay attention to the national and international regulations
regarding selectivity and line protection.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 18 of 28
5.2.2 Plug assignments (RJ45) The data transfer of the RoughCam IPM2036 uses a
100 Mbit/s Ethernet connection (100BASE-TX). If the cable termination uses a
plug, the latter should be plugged into the RJ45 PoE slot of the network
device (PSE). Prior to connecting it to the camera, the network device (PSE)
can already be supplied with power, hence there is no ,,power ON” priority
which has to be observed.
Attention! Use appropriate RJ45 plugs! Check the cable shielding, cross-
section and the outside diameter! Attention! It is imperative to ensure a
correct routing of the individual wires according to the EIA/TIA-568B”
Attention! Finally, check your network installation with a Class-D Link Test.
Detailed instructions on how to connect a RJ45 plug are available in our video
tutorial: “SAMCON 03 Mounting and installing the RJ45 jack to SAMCON cables”
https://go.samcon.eu/v03
Figure 5-8 Plug assignment, RJ45
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 19 of 28
5.2.3 Tests prior to switching on voltage Attention! Prior to starting the
device, perform all tests as indicated by the national regulations.
Furthermore, check the correct function and installation of the device in
accordance with this User Manual and other applicable regulations. Attention!
Incorrect installation or operation of the camera may lead to a loss of
warranty! Attention! Do not switch on the camera at temperatures below 0°C!
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 20 of 28
6 Working inside the camera housing
The customer may open the housing only if it is absolutely necessary. Only
exchanging the SD memory card or a hardware reset are reasons for this. 6.1
Preparation for work:
Attention! Prepare your work carefully and in accordance with the relevant
regulations.
6.2 Opening the housing If the RoughCam IPM2036 is equipped with a weather
protection roof this has to be removed prior to starting your work! To do so,
loosen the 4x12mm button head screws M4*0.7 at the front and rear sides of the
bracket holders (Figure 6-1).
Figure 6-1 Removing the weather protection roof
To open the stainless-steel housing (T11 VA2.0.x.x) of RoughCam IPM2036,
loosen the eight cylinder-head hexagon screws (DIN 912/ ISO 4762) together
with their spring rings (DIN 127A) on the rear side of the cable and power
supply flange (see Figure 6-3). Caution: do not touch the screw threads with
your skin or clothes! On the threads, there is LOCTITE® 243TM (chemical basis
is dimethacrylate ester) applied to prevent the bolted connection from
unintentional loosening because of impacts and vibrations and to seal them
tightly. It is not permitted for the customer to open the front-side sight
glass flange! There is no need of such an action.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 21 of 28
Figure 6-2 Opening the RoughCam IPM2036 (similar illustration)
Carefully pull out the cable and supply flange to the rear, as straight as
possible. Because of negative pressure, it may be difficult to remove the
flange. Attention: The mounting adapter with the housing’s PTC heater, camera
module and optics, as well as the temperature control, and (if applicable)
auxiliary relays and terminal block are fixed on the cable and supply flange.
Dealing with these components, too, you have to work very carefully and
precisely in order to avoid canting and damage to the inbuilt components!
Caution: do not touch the cylindrical fit surface with your skin or clothes!
On the surface, there is oil lubricating paste to protect the surface against
fretting corrosion and mechanical stresses. When you open the housing, pay
attention that you do not damage the GYLON® flat seal (blue, RAL5012) and do
not make it dirty! The flat gasket is loosely attached to the cable and power
supply flange. It is fixed only by the bolted connections!
Control key
Figure 6-3 Structure of the camera
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 22 of 28
6.3 Removing / inserting a SD memory card
Note: The RoughCam IPM2036 has a slot for a micro SDHC memory card (card not
included). Saved video files can be played and deleted via the web interface.
They are also available in a download list. Moreover, the videos available in
the memory card can also be accessed via FTP server in the network. If the
memory card has to be replaced by the user, it should be, as far as possible,
empty and pre-formatted with an ext4 or vFAT file system.
When touching electrical components, observe potential equalization (grounding
of the body): carry electrostatic-discharge clothes, a PE wristband etc.!
6.4 Hardware Reset
To set all the parameters of the RoughCam IPM2036 (including the IP address)
to default values, you should run a hardware reset. The parameters can be
reset via the web interface or manually. If the camera placed in the network
can no longer be reached or its state is uncontrollable, the reset should be
performed manually. To do so, proceed as follows:
1. Disconnect the camera installation module (Axis M2036-LE) from power
supply. 2. Press and hold the control button (see the illustration below) and,
at the same time,
connect the system to the voltage supply (PoE). 3. Hold the control button
pressed for about 30 seconds. 4. Release the control button. After about a
minute, the AXIS M2036-LE will return to
factory defaults. If there is a DHCP server in the network, the IP address
will be the following: 192.168.0.90 (subnet masking 255.255.255.0). 5. IP
address and password can be redefined. If the hardware reset is not
satisfactory or the network camera shows serious conflicts or does not work as
usual (errors in the browser visualisation, frozen images, control commands no
longer processed, slowing down of the system, etc.), it may be necessary to
re-install the current firmware, or to install an update (see Chapter 7).
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 23 of 28
6.5 Closing of the pressure-resistant housing For closing the housing, proceed
in reverse order as when opening. Use exclusively original screws included in
the supply. The cable and power-supply flange (K1) is fixed by 8 cylinder-head
screws M4*0.7 (ISO metric right-turning) with 12 mm thread length (DIN 912/
ISO 4762, grade 6g). Materials of bolted connections are identical to the
stainless steel housing (standard material no. 1.4404 AISI316L).
Attention! Do not lock-in any foreign objects in the housing. Dismantled screw
locks (spring washers DIN 127A) must be used again. The GYLON® gasket must be
used in undamaged condition, according to the flange hole pattern, and placed
between the flange and the hull. The lateral position of the flat surface /
contact surface is arbitrary. If, when closing the housing, you see that the
surface of the fitting gap is dirty or insufficiently lubricated, clean it
with a clean cloth and de-grease it with a suitable cleaning agent. Then re-
grease it with lubricant suitable for this specific application (e.g.,
Molykote® P-40 gel for standard applications or special grease OKS 403 in the
event of heavy seawater influence). Cylinder-head bolts for connection of the
camera body with the flange component must be tightened at a 3 Nm torque –
crosswise and evenly!
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 24 of 28
7 Network access and visualization
The most important procedures of the first starting up the camera are
described below. The configuration menu of the web surface allows an intuitive
navigation and offers several configuration possibilities. For detailed
documentation and information how to use the web Interface, please see the
User Manual for Axis or visit the following website:
https://help.axis.com/axis-m2036-le
https://help.axis.com/api/download/um_m20_bullet_camera_series_t10175189_de_2204.pdf
The delivered RoughCam IPM2036 is set to the applicable net frequency (50Hz or 60Hz). If the camera is used at a location with a differing net frequency, the image might start to flicker, particularly in surroundings with fluorescent tubes. In such a case, the applicable settings have to be carried out inside the menu “System Options > Advanced > Plain Config”.
User:
root
Password: root
7.1 Browser Support
A list of the currently supported web browsers, operating systems, required
add-ons, etc. can be viewed at:
https://help.axis.com/access-your-device https://www.axis.com/support
7.2 Assigning the IP address
The RoughCam IPM2036 is intended for use in an Ethernet network and requires
an IP address to access and control it. In the most today’s networks, a DHCP
server is integrated. This server automatically assigns an IP address.
If there is no DHCP server available in the network, the IP default address of
RoughCam IPM2036 is “192.168.0.90” (subnet masking 255.255.255.0). With the
“AXIS IP Utility”, it is possible to determine the IP address under Windows;
the included USB stick contains this application.
https://www.axis.com/support/tools/axis-ip-utility
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 25 of 28
If it is not possible to assign the IP address, it might be necessary to
change the firewall settings!
The “AXIS IP Utility” tool automatically recognizes all RoughCam devices and
visualises them in the device list. It can also be used to manually assign a
static IP address. For this purpose, the RoughCam IPM2036 network camera has
to be installed in the same physical network segment (physical subnet) as the
computer on which the AXIS IP Utility is running. The network signature of
RoughCam IPM2036 is “AXIS M2036-LE” (see Figure 7-1). MAC address and serial
number for clear device identification are also detected and displayed.
RoughCam IPM2036
Figure 7-1 Axis IP Utility
7.3 Password/ Identification
The following user name is set at the factory:
root
The following password is set at the factory:
root
8 Maintenance / Modification
The required maintenance intervals are specific to the individual devices. The
operating company has to determine these intervals depending on the
application parameters. If maintenance measures are necessary they have to be
initiated and/or executed. Repairs may only be carried out with original parts
of SAMCON Prozessleittechnik GmbH. In case of doubt, send the part in question
back to SAMCON Prozessleittechnik GmbH. Rebuilding of or alterations to the
devices are not permitted.
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 26 of 28
9 Disposal / Recycling
When disposing of the device, nationally applicable regulations must be
observed. This Document is subject to alterations and additions.
10 Drawings, 3D models, certificates & further documentation
All drawings, 3D models, certificates and other information are available in
the download area of the product page on our website:
https://www.samcon.eu/en/products/roughcam/roughcam-ipm2036/
If you wish additional technical information, please contact us at:
support@samcon.eu
Doc.-ID: 220815-PT10BA-ES-RoughCam IPM2036_en_rev.01.docx, Page 27 of 28
Schillerstrasse 17, 35102 Lohra-Altenvers, Germany
www.samcon.eu, info@samcon.eu Phone: +49 6426 9231-0, fax: – 31
References
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- YouTube
- YouTube
- How to assign an IP address and access your device User manual
- AXIS M2036-LE Bullet Camera User manual
- AXIS M2036-LE Bullet Camera | Axis Communications
- Welcome to Axis support | Axis Communications
- AXIS IP Utility | Axis Communications
- RoughCam IPM2036- Robust Quad HD/ 4MP IP Camera with IR illumination, IP66, IP68
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>