SAMCON ExCam IPQ1715 Explosion Proof 21xoptical zoom Camera User Manual
- June 9, 2024
- SAMCON
Table of Contents
- SAMCON ExCam IPQ1715 Explosion Proof 21xoptical zoom Camera
- Introduction
- Technical data
- Safety Instructions
- Installation
- Electrical connection
- Working inside the camera housing (Ex-d)
- Network access and visualization
- Maintenance/ Modification
- Drawings & 3D models, Certificates and further documentation
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SAMCON ExCam IPQ1715 Explosion Proof 21xoptical zoom Camera
Introduction
The ExCam IPQ1715 is a powerful IP motor-zoom camera. The camera is certified according to ATEX, IECEx, as well as EAC-Ex. It has a high-definition television resolution (1920×1080) and is equipped with a powerful motor-zoom autofocus lens (21x optical zoom) and a Deep Learning Processor Unit (DLPU). The ExCam series is certified both in accordance with the European (ATEX) and international directive (IECEx). The explosion-protected housing is approved for ATEX group II for zones 1, 2, 21 and 22 including the explosion groups IIC / IIIC. To see other approvals, please visit our website at www.samcon.eu When designing the ExCam IPQ1715, we attached a very high importance to safety, mechanical precision and high quality of stainless steel.
Technical data
Explosion protection
Illustration of the model key
- Ex product- name
| 2) Type| 3) Housing- combination| 4) Temp.- range| 5) Cable length [m]| 6)
Cable termin.
---|---|---|---|---|---
ExCam IPQ1715| T08-| VA2.2.K1.BOR-| L.N-| 005.N-| P-
T08-| VA2.2.K1.BOR-| L.N-| 005.A-| P-
T08-| VA2.2.K1.BOR-| L.N-| 005.N-| T-
T08-| VA2.2.K1.BOR-| L.N-| 005.A-| T-
T08-| VA2.2.K1.BOR-| LL.H-| 005.N-| P-
T08-| VA2.2.K1.BOR-| LL.H-| 005.A-| P-
T08-| VA2.2.K1.BOR-| LL.H-| 005.N-| T-
T08-| VA2.2.K1.BOR-| LL.H-| 005.A-| T-
T08-| VA2.2.K1.BOR-| L.HH-| 010.N-| T-
Explanations:
Electrical parameters of the camera
- Supply of 24 V DC for the heating:
- Voltage supply: 22 V DC < Uin < 26 V DC
- Power consumption: approx. 40W@-60°C (depends on temperature)
- Power supply of the camera via Ethernet (PoE):
- Voltage supply: PoE, IEEE 802.3af/802.3at type 2 class 4
- Reference voltage: +48 V DC (44…54 V DC)
- Maximum power consumption: 13.5 W
- Typical power consumption: 12.0 W
Connection cable Ex-d – Ex-e
- Description: Data transfer and power supply of the camera module (compliant with DIN EN 60079-14)
- Jacket colour: green (GN), similar to RAL3001
Connection cable for models -L- (SKD02-T/ASKD02-T)
- Systemcable SKD02-T:
- Outside diameter: 8.9 ± 0.3 mm
- Bending radius: 8 x Da when installed and 4 x Da after relocation
- Data line: 4 x 2 x AWG23/1 CAT.6
- Properties: PUR halogen-free, flame-retardant, UV-resistant, chemical resistance, shielded
Quick link: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKD02-T_Datasheet.pdf
- Systemcable ASKD02-T:
- Outside diameter: 13.20 ± 0.3 mm
- Bending radius: 8 x Da when installed and 4 x Da after relocation
- Data line: 4 x 2 x AWG22-23/1 CAT.6
- Properties: PUR halogen-free, flame-retardant, UV-resistant, chemical resistance, shielded (see www.samcon.eu)
Quicklink: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/ASKD02-T_Datasheet.pdf
Connection cable for models –LL- with heater (SKDP03-T/ASKDP03-T)
- Systemcable SKDP03-T:
- Outside diameter: 12.40 ± 0.3 mm
- Bending radius: 8 x Da when installed and 4 x Da after relocation
- Data line: 4 x 2 x AWG23/1 CAT.6
- Performance elements: 3G1.5 (BK-BU-GN/YE)
- Properties: PUR halogen-free, flame-retardant, UV-resistant, chemical resistance, shielded
Quick link: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKDP03-T_Datasheet.pdf
- Systemcable ASKDP03-T:
- Outside diameter: 15.50 ± 0.6 mm
- Bending radius: 15 x Da when installed and 10 x Da after relocation
- Data line: 4 x 2 x AWG23/1 CAT.6
- Performance elements: 3G1.5 (BK-BU-GN/YE)
- Properties: PUR halogen-free, flame-retardant, UV-resistant, chemical resistance, shielded
Quicklink: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/ASKDP03-T_Datasheet.pdf
Connection cable for model with cool.Jacket (SKD05-HT)
- Description: Data transfer and power supply of the camera module (compliant with DIN EN 60079-14)
- Jacket colour: Grey (GY)
- Systemcable SKD05-HT:
- Outside diameter: 6.60 ± 0.2 mm
- Bending radius: 8 x Da when installed and 4 x Da after relocation
- Data line: 4 x 2 x AWG26/7 CAT.6
- Properties: FEP, flame-retardant, UV-resistant, chemical resistance, for extreme hot temperatures
Quick link: https://www.samcon.eu/fileadmin/documents/en/60-Assembling%26mounting/SKD05-HT_Datasheet.pdf
Video-technical characteristics
We use the AXIS Q1715 Network Camera in a pressure-resistant enclosure. For
details, please refer to the Product Documentation, and video-technical data
of AXIS®:
https://www.axis.com/products/axis-q1715
Other technical data
Camera (Ex-d) | Terminal box (Ex-e) | |
---|---|---|
Permissible ambient temperature | -40°C … +50°C (for PoE power supply) |
-60°C … +50°C (in the event of additional 24 V DC power supply)
| -60°C … +55°C
Protection class as per EN 60529/IEC 529| IP66/68 (Test conditions: 24h/3m
water column 5°C°)| IP66
Housing material| stainless steel, mat. no. 1.4404| polyester resin
Weight| about 6 kg| about 1 kg
Dimensions| D113mm x 262mm| 145mm x 145mm x 71mm
Safety Instructions
Please absolutely observe the safety directions stated in the Ex-installation instructions of the T08 ExCam series!
Quick link:https://www.samcon.eu/fileadmin/documents/en/20-Ex-Cameras-
Analog/ExCam-Series-T08-EX-Installation-Manual-2020.pdf
It is absolutely mandatory to observe the national safety regulations and
regulations for prevention of accidents, as well as the safety instructions
given below in this User Manual!
- Attention! Cameras of the type T08 ExCam are not suitable for use in zone 0 and zone 20. The ambient temperature, temperature class and explosion group as stated on type plate must be observed! Alterations are not permitted! The camera is to be operated in sound conditions and in the intended way.
- Attention! Only original parts of SAMCON Prozessleittechnik GmbH may be used for repairs. Repairs concerning the explosion protection may only be carried out in accordance with the nationally applied regulations and by SAMCON Prozessleittechnik GmbH.
- Attention! Prior to installation, take external sources of heat or cold into account! The temperature ranges prescribed for storage, transport and operation must be adhered to!
- Attention! Observe the warnings given on the type plate:
- “WARNING – DO NOT OPEN IN HAZARD AREAS“
- “WARNING – DO NOT OPEN WHILE ENERGIZED“
- The use in hazardous areas with regard to temperature and dust layers is defined in the respective national regulations.
- When installing the ExCam, adhere to the requirements of the EN/IEC 60079-14.
Installation
For erecting and operating the camera, the relevant national regulations, as well as the generally accepted rules of technology shall prevail. Before mounting the camera, thoroughly check it for any transport damage, especially regarding the housing and the cable. installation, electrical connection and the commissioning must only be carried out by qualified specialists.
Work preparation:
Attention! Prepare your work carefully and in accordance with the
relevant regulations.
Attention! Depending on classification of hazard areas, a work approval
has to be obtained. When opening the pressure-resistant enclosure under
voltage, it is absolutely necessary to prevent potentially explosive
atmosphere!
To ensure the best image quality delivered by the network camera, plan the installation site carefully (consider light conditions, object distance or size, angle and minimum object distance to the focus).
- Use appropriate tools and aids
- When working, ensure a safe stand.
- Make sure that any static charge is avoided
Attention! Please adhere to the national security, installation and
accident prevention regulations (e.g. DIN EN 60079-14) and the safety
instructions in this User Manual, as well as the ones in the Installation
Guidelines!
Attention! Adhere to the provisions of the IECEx ATEX andEX installation
instructions for mounting and commissioning!
The ExCam® IPQ1715 consists of a flame-proof camera housing (Ex-d) and, optionally (models with a terminal box …-T), a terminal box of a high degree of safety (Ex-e). Both areas are separated by a reinforced 5 m line. Mount the camera according to the desired field of view. Install the terminal box so that a good accessibility is provided, in order to facilitate electrical connection.
Attention! Please pay attention to the national and local regulations for
mounting heavy loads. In case of doubt, take appropriate security measures.
Drawings for drilling hole patterns and further information can be viewed on
our product page:
Quick link: https://www.samcon.eu/en/products/network/excam-ipq1715/
Option mounting accessories
Electrical connection
- Attention! The electrical connection of the equipment may only be carried out by qualified and skilled personnel!
- Attention! It is absolutely necessary to ground the ExCam® series housing via the PA connection.
- Attention! Please observe the national security, installation and accident prevention regulations (e.g. DIN EN 60079-14) and the safety instructions in this User Manual, as well as the ones in the Installation Guidelines!
The delivered ExCam® IPQ1715 is equipped with an electrical connection cable of the type (A)SKD02-T (models with model key -L-) or (A)SKDP03-T (models with model key -LL-). The maximum transmission range from the camera to the next active network interface is 100 meters and can be individually specified by the client. The user is NOT authorized to do electrical connection procedures inside the pressure-resistant enclosure.
Potential equalization
The potential equalization/grounding of the camera body is absolutely
necessary, in order to avoid static charges and thus the formation of sparks.
For this purpose, a screw terminal is provided at the rear side, at the bottom
(right) (see Figure 5-1). The cross-section of the equipotential bonding
should comply with the National Ground Rules (at least 4 mm2).
Wiring table:
Potential| Colour (IEC 60757)| Cross- sec tion|
Comment
---|---|---|---
PA| GN/YE| 4 mm2 (rigid)| Terminal: Slotted screw M4x0.7 (DIN 84) with washer
Ø9mm (DIN 125A), Keep 3 Nm tightening torque!
Connection work at the device (terminal box) and fuse protection
- Supply of 24 V DC for the heating
- Power supply: 22 V DC < Uin < 26 V DC
- Power consumption: approx. 40W@-60°C (depends on the temp.)
- Power supply for the camera (PoE)
- Power supply: PoE, IEEE 802.3af/802.3at type 1 class 3
- Reference voltage: +48 V DC (44…54 V DC)
- Maximum power consumption: 13.5 W
- Typical power consumption: 12.0 W
The figures 5.2 and 5.3 illustrate the potential cable terminations of the ExCam IPQ1715. Possible terminations are: terminal box or plug.
- Attention! Never open the Ex-e terminal box under voltage!
- Attention! Adhere to the international installation regulations for connection chambers with increased safety (Ex-e).
- Attention! Adhere to attached separate Usual Manual for the Exe terminal box.
Video Tutorial:
Please view our video tutorial: “SAMCON 01 Wiring the cable SKDP03-T to
the junction box ExTB-3” https://go.samcon.eu/v01
The pin assignment of the SKD02-T is executed in accordance with the standard EIA/TIA-568B for 100BaseTX and 24VDC, as follows:
Camera (Ex-d) (T568B)| Colour SKD02-T
(IEC60757)
| Terminal ExTB-3| Cross-sec tional sur face| Comment
---|---|---|---|---
Tx+| WH / OG| 1| 0.32 mm2| Solid conductor
Tx-| OG| 2| 0.32 mm2| Solid conductor
Rx+| WH / GN| 3| 0.32 mm2| Solid conductor
Rx-| GN| 4| 0.32 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.32 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.32 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.32 mm2| Solid conductor
(PoE GND)| BN| 8| 0.32 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
The pin assignment of the ASKD02-T is executed in accordance with the standard EIA/TIA-568B for 100BaseTX and 24VDC, as follows:
Camera (Ex-d) (T568B)| Colour ASKD02-T
(IEC60757)
| Terminal ExTB-3| Cross- sec tional surface| Comment
---|---|---|---|---
Reinforcement| YE / GN| PE| 2.5 mm2| Flex
Tx+| WH / OG| 1| 0.32 mm2| Solid conductor
Tx-| OG| 2| 0.32 mm2| Solid conductor
Rx+| WH / GN| 3| 0.32 mm2| Solid conductor
Rx-| GN| 4| 0.32 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.32 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.32 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.32 mm2| Solid conductor
(PoE GND)| BN| 8| 0.32 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
The pin assignment of the SKDP03-T is executed in accordance with the standard EIA/TIA-568B for 100BaseTX and 24VDC, as follows:
Camera (Ex-d) (T568B)| Colour SKDP03-T
(IEC60757)
| Terminal ExTB-3| Cross- sec tional surface| Comment
---|---|---|---|---
Tx+| WH / OG| 1| 0.32 mm2| Solid conductor
Tx-| OG| 2| 0.32 mm2| Solid conductor
Rx+| WH / GN| 3| 0.32 mm2| Solid conductor
Rx-| GN| 4| 0.32 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.32 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.32 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.32 mm2| Solid conductor
(PoE GND)| BN| 8| 0.32 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
L+| BK| 9| 1.5 mm2| L+ 24VDC
L-| BU| 10| 1.5 mm2| L- 24VDC
PE| YE / GN| PE| 1.5 mm2| PE
The pin assignment of the ASKDP03-T is executed in accordance with the standard EIA/TIA-568B for 100BaseTX and 24VDC, as follows:
Camera (Ex-d) (T568B)| Colour ASKDP03-T
(IEC60757)
| Terminal ExTB-3| Cross-sec tional sur face| Comment
---|---|---|---|---
Reinforcement| YE / GN| PE| 2.5 mm2| Flex
Tx+| WH / OG| 1| 0.32 mm2| Solid conductor
Tx-| OG| 2| 0.32 mm2| Solid conductor
Rx+| WH / GN| 3| 0.32 mm2| Solid conductor
Rx-| GN| 4| 0.32 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.32 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.32 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.32 mm2| Solid conductor
(PoE GND)| BN| 8| 0.32 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
L+| BK| 9| 1.5 mm2| L+ 24VDC
L-| BU| 10| 1.5 mm2| L- 24VDC
PE| YE / GN| PE| 1.5 mm2| PE
- Attention! Introduce the foiling up to about 15 mm to the terminals, in order to prevent alien crosstalk. Make sure that the foiling cannot cause any short circuit of the data pairs!
- Attention! Bring the twisted pair composite approximately 10 mm close to the terminals, in order to ensure the interference immunity.
- Attention! Use only terminals approved by SAMCON.
- Attention! Finally, check your network installation by per Class-D Link Test.
Note: If the camera is equipped with a camera cooling system (SAMCON
cool.Jacket for model key type L.HH), the wiring is executed via the cable
SKD05-HT.
The pin assignment of the SKD05-HT is executed in accordance with the standard
EIA/TIA-568B for 100BaseTX and 24VDC, as follows:
Camera (Ex-d) (T568B)| Colour SKD05-HT
(IEC60757)
| Terminal ExTB-3| Cross-sec tional sur face| Comment
---|---|---|---|---
Tx+| WH / OG| 1| 0.13 mm2| Solid conductor
Tx-| OG| 2| 0.13 mm2| Solid conductor
Rx+| WH / GN| 3| 0.13 mm2| Solid conductor
Rx-| GN| 4| 0.13 mm2| Solid conductor
(PoE +48 VDC)| WH / BU| 5| 0.13 mm2| Solid conductor
(PoE +48 VDC)| BU| 6| 0.13 mm2| Solid conductor
(PoE GND)| WH / BN| 7| 0.13 mm2| Solid conductor
(PoE GND)| BN| 8| 0.13 mm2| Solid conductor
GND/SHD| YE / GN| PE| 2.5 mm2| Flex
An appropriate water supply has to be provided by the customer. For further information, please refer to the applicable datasheet of the ExCam IPQ1715 cool.Jacket.
External connection and protection
There are several options of routing the ExTB-3 terminal box in a safe area:
Direct routing from the ExTB-3 into the safe area
In case of direct routing from the ExTB-3 into the safe area, the power
supply and the voltage signal is led from the safe area to the terminal box.
Please observe the terminal box assignment, as described above.
- Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14.
- Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations.
Routing via ExConnection Rail (optional accessories)
In case of routing the ExTB-3 into an ExConnection Rail, larger
installation distances can be covered.
Note: In hazardous areas, the ExConnection Rail (optional accessories)
acts as a PoE+ switch, a media converter from copper to fiber-optic cable, as
well as a power supply for the cam-eras.
- Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14.
- Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations.
Appropriate cables & cable entries
An integral part of the device safety is the correct selection of the cables,
wires and cable entries.
- Attention! Cables and wires must comply with the requirements of the IEC 60079-0/1/7 & 14.
- Attention! The supply line must have a sufficient cross-section. The cable protection must comply with national and international regulations.
To view our non-binding configuration and planning guidelines, please visit our website:
Perhaps our video will help you: “Cables for flameproof devices in potentially explosive atmospheres” http://go.samcon.eu/video-cable-ex
Particularly for installations requiring a suitable barrier gland, make sure that you handle them correctly and observe the rules and notes given in the respective mounting and as-sembly instructions.
We show the basic procedures in the following video tutorial:
Video Tutorial: “SAMCON 02 Mounting and installing Ex-d barrier glands to
ExConnection Rails” https://go.samcon.eu/v02
Fusing
PoE power supply requires no fuses. The power supply fusing depends on the
cable cross-section and length.
- Attention! The protection recommendation for fusing relates to 40W@24VDC at 100 meters 1.5 mm2
- Attention! When the heating switches on, there are high current peaks! Use slow-blow fuses.
- Attention! Please pay attention to the national and international regulations regarding selectivity and line protection.
Potential/ Wire no.| Colour (IEC60757)| Conductor|
Voltage| Maximum power consumption/fus ing:
---|---|---|---|---
L+ / 1| BK| 1.5mm2, stranded wire| +24 V DC| 40 W of continuous power Fine-
wire fuse (L+) 4000 mA -T- slow-blow (high inrush load!)
L- / 2| BU| 1.5mm2, stranded wire| 0 V DC / GND
PE| YE/GN| 1.5mm2, stranded wire| PE|
Plug assignment (RJ45)
The data transfer of the ExCam IPQ1715 series uses a 100 Mbit/s Ethernet
connection (100BASE-TX). If the cable termination uses a plug, the latter
should be plugged into the RJ45 PoE slot of the network device (PSE). Prior to
connecting it to the camera, the network device (PSE) can already be supplied
with power, hence there is no „power ON“ priority which has to be observed.
- Attention! Use appropriate RJ45 plugs! Check the cable shielding, cross-section and the outside diameter!
- Attention! It is imperative to ensure a correct routing of the individual wires according to the “EIA/TIA-568B”
- Attention! Finally, check your network installation by per Class-D Link Test.
Detailed instructions on how to connect an RJ45 plug are available in our video tutorial: “SAMCON 03 Mounting and installing the RJ45 jack to SAMCON cables” https://go.samcon.eu/v03
Tests prior to switching on voltage
- Attention! Prior to starting the device, perform all tests as indicated by the national regulations. Furthermore, check the correct function and installation of the device in accordance with this user manual and other applicable regulations.
- Attention! Incorrect installation and operation of the camera may lead to a loss of warranty!
- Attention! Do not switch on the camera at temperatures below 0°C!
Working inside the camera housing (Ex-d)
The customer may open the housing only if it is absolutely necessary. Only exchanging the SD memory card or a hardware reset are reasons for this.
Work preparation
- Attention! Prepare your work carefully and in accordance with the relevant regulations.
- Attention! Depending on classification of hazard areas, a work approval has to be obtained. If you adjust the camera yourself or open the pressure-resistant enclo-sure (Ex-d) under voltage, it is absolutely imperative to prevent potentially explosive atmosphere!
Opening the pressure-resistant housing
-
WARNING – MAY NOT BE OPENED IN HAZARD AREAS
-
Note: Depending on classification of hazard areas, a work approval has to be obtained.
Even after switching on the power supply, it is absolutely imperative to avoid potentially explosive atmosphere when opening the camera housing. Opening the housing requires disassembly and working in a safe (i.e. non-explosive!) area. -
Attention! Heed that you do not damage the thread surface of the flame-proof gap.
-
Attention! Heed that you do not damage the housing seals. Keep them clean!
If the ExCam IPQ1715 is equipped with a weather protection roof this has to be removed prior to starting your work. To do so, loosen the 4x8mm lens screws M4*0.7 at the front and rear sides of the bracket holders (Figure 6-1).
To open the stainless steel housing (T07 VA2.2.x.x) of the ExCam IPQ1715, loosen the eight cylinder-head hexagon screws (DIN 912/ ISO 4762) together with their spring rings (DIN 127A) on the rear side of the cable and power supply flange (see Figure 6-3). Caution: do not touch the screw threads with your skin or clothes! On the threads, there is LOC-TITE® 243™ (chemical basis is methacrylate ester) applied to prevent the bolted con-nection from unintentional loosening because of impacts and vibrations and to seal them tightly. It is not permitted for the customer to open the front-side sight glass flange! There is no need of such an action.
Carefully pull out the cable and supply flange to the rear, as straight as
possible. Because of negative pressure, it may be difficult to remove the
flange. The cylindrical clearance fit (H8f7 – DIN ISO 286) of the camera body
and flange may not be tilted! Risk of damage to the flame-proof gap (DIN EN
60079-1:2012)!
Attention: The mounting adapter with the housing’s PTC heater, the camera
module and the optics, as well as the temperature control, and (if applicable)
auxiliary relays and terminal blocks are fixed to the cable and supply flange.
Again, any work has to be carried out very carefully and precisely in order to
avoid tilting and damaging the installed components! Caution: do not touch the
cylindrical fit surface with your skin or clothes! On the surface, there is
oil lubricating paste to protect the surface against fretting corrosion and
mechanical stresses. When you open the housing, pay attention that you do not
damage or pollute the GYLON® flat seal (blue, RAL5012)! The flat gasket is
loosely attached to the cable and power supply flange. It is fixed only by the
bolted connections!
- Attention! Make sure not to damage the surface of the drill hole and the shaft (fit-ting) of the flame-proof gap.
- Attention! Pay attention not to damage the seals. Keep them clean!
Removing/inserting an SD memory card
Note: The ExCam IPQ1715 has a slot for a micro SDHC memory card. Saved
video files can be played and deleted via the web interface. They are also
available in a download list. Moreover, the videos available in the memory
card can also be accessed via FTP server in the network. If the memory card
has to be replaced by the user, it should be, as far as possible, empty and
pre-formatted with an ext4 or vFAT file system.
When touching electrical components, observe potential equalization (grounding
of the body): carry electrostatic-discharge clothes, a PE wristband etc.!
Hardware Reset
To re-set all parameters of the ExCam IPQ1715 (including the IP address) to
default set-ting, a hardware reset has to be carried out. The parameters can
be reset via the web interface or manually. If within the network, the camera
can no longer be reached or if it is in an uncontrollable state, the reset
should be performed manually. To do so, proceed as follows:
- Disconnect the camera installation module (Axis Q1715) from the power supply.
- Press and hold the control button (see the illustration below) and, at the same time, connect the system to the voltage supply (PoE).
- Hold the control button pressed for about 30 seconds.
- Release the control button. After about a minute, the AXIS Q1715 will return to factory default settings. If there is a DHCP server available in the network, the IP address will be the following: 192.168.0.90 (subnet masking 255.255.255.0).
- IP address and password can be redefined. If the hardware reset is not satisfactory or the network camera shows serious conflicts or does not work as usual (errors in the browser visualisation, frozen images, control commands no longer processed, slowing down of the system , etc.), it may be necessary to re-install the current firmware, or to install an update (see Chapter 7).
Closing the pressure-resistant housing
For closing the housing, proceed in reverse order as when opening. Use
exclusively original screws included in the supply. The cable and power-supply
flange (K1) is fixed by 8 cylinder-head screws M4*0.7 (ISO metric right-
turning) with 30 mm thread length (DIN 912/ ISO 4762, grade 6g). Materials of
bolted connections are identical to the pressure-resistant stainless steel
housing (standard material no. 1.4404 AISI316L). Check whether the threaded
holes are undamaged and clean. Before closing, it is also absolutely
imperative to check the flame-proof gap (circular cylindrical fit).
- Attention! If any mechanical damages occurred to the fitting gap, it is no longer allowed to use the housing!
- Attention! Do not lock-in any foreign objects in the housing.
Dismantled screw locks (spring washers DIN 127A) must be used again. The GYLON® gasket must be used in undamaged condition, according to the flange drill-ing hole pattern, and placed between the flange and body. The lateral position of the flat surface/contact surface is arbitrary. If, when closing the housing, you see that the surface of the fitting gap is dirty or insufficiently lubricated, clean it with a clean cloth and de-grease it with a suitable cleaning agent. Then re-grease it with lubricant suitable for this specific application (e.g., Molykote® P-40 gel for standard applications or special grease OKS 403 in the event of heavy seawater influence).
The screwed connections of flange and body components must always be tightened
cross-wise at a torque of 3 Nm! Do not tighten the screw too strongly! It can
cause rupture of the cylinder head or over-stretching the threads, and thus to
impairment of the pressure resistance or ignition protection class.
Cylinder-head bolts for explosion-proof connection of the camera body with the
flange component must always be tightened at a 3 Nm torque – crosswise and
evenly!
Battery
ExCam IPQ1715 model …-L.N-… is equipped with a Maxell button cell CR2032H.
This cell supplies energy to the internal real time clock (RTC) but is not
high temperature resistant. The customer is not allowed to replace the
battery! In this case, please contact the manu-facturer. For models X.H and
X.HH the battery is removed.
Network access and visualization
The most important procedures of the camera commissioning are described below.
The configuration menu of the web surface allows intuitive navigation and
offers several configuration possibilities. For detailed documentation and
information how to use the web Interface, please see the Axis User Manual or
visit the following website:
https://www.axis.com/products/axis-q1715/support
The delivered ExCam IPQ1715 is set to the applicable net frequency (50Hz or 60Hz). If the camera is used at a location with a differing net frequency, a flickering of the picture might be noticeable, particularly in surroundings with fluorescent tubes. In such a case, the applicable settings have to be carried out within the menu “System Options > Advanced > Plain Config”.
- User: root
- Password: root
Browser Support
A list of the currently supported web browsers, operating systems, required
add-ons, etc. can be viewed at:
Assigning the IP address
The ExCam IPQ1715 is intended for use in an Ethernet network and it requires
an IP address to access and control it. In the most today’s networks, a DHCP
server is integrated. This server automatically assigns an IP address.
If there is no DHCP server available in the network, the IP default address of
ExCam IPQ1715 is “192.168.0.90” (subnet masking 255.255.255.0). With the “AXIS
IP Utility“ it is possible to determine the IP address under Windows. This
software and other useful tools are available free of charge from axis.
https://www.axis.com/support/tools/axis-ip-utility
In case it is not possible to assign the IP address, it might be necessary
to change the firewall settings!
The “AXIS IP Utility“ tool automatically recognizes all ExCam devices and
displays them in the device list. It can also be used to manually assign a
static IP address. For this purpose, the ExCam IPQ1715 network camera has to
be installed in the same physical network segment (physical subnet) as the
computer on which the AXIS IP Utility is running. The network signature of
ExCam IPQ1715 is “AXIS Q1715” (see Figure 7-1). MAC address and serial number
for clear device identification are also detected and displayed.
Password/ Identification
- The following user name is set at the factory: root
- The following password is set at the factory: root
Maintenance/ Modification
The applicable regulations for the maintenance and servicing of electrical
devices in potentially explosive atmospheres must be adhered to.
The required maintenance intervals are specific to the individual devices. The
operating company has to determine these intervals depending on the
application parameters. The maintenance tasks especially include examination
of parts on which the ignition protection depends (e.g., proper condition of
the casing, seals and cable entry points). If maintenance measures are
necessary they have to be initiated and/or executed.
Repair and correction
Repairs may only be carried out with original parts of SAMCON
Prozessleittechnik GmbH. Damaged pressure-resistant housings have to be
replaced completely. If in doubt, send the part in question back to SAMCON
Prozessleittechnik GmbH. Repairs concerning the explosion protection must only
be carried out in accordance with nationally applied regulations by SAMCON
Prozessleittechnik GmbH or by an electrical technician authorised by SAMCON
Prozessleittechnik GmbH. Rebuilding of or alterations to the devices are not
permitted.
Disposal/ Recycling
When disposing of the device, nationally applicable regulations must be
observed. This Document is subject to alterations and additions.
Drawings & 3D models, Certificates and further documentation
All drawings, 3D models, certificates and other information are available in
the download area of the product page on our website:
https://www.samcon.eu/en/products/network/excam-ipq1715/
If you wish additional technical information, please contact us at: support@samcon.eu
History of revisions
- Product: ExCam® IPQ1715
- Title: User Manual for ExCam® IPQ1715
- Doc. -Id. 220601-PT08BA-ES-ExCam IPQ1715_en_rev.01.docx
- Author: Eva Schneider, Grad. Eng. (UAS)
- Created on: 01.06.2022
Rev. Index| Date| Name| Comment| Approved by the
ATEX Supervisor
---|---|---|---|---
0| 01.06.2022| E. Schneider| Compilation of the document|
1| 23.01.2023| E. Schneider| Change of EAC-Ex Certificate| Thiemo Digital
unterschrieben von ThiemoGruber
DN: cn=Thiemo Gruber, o=Samcon
Gruber GmbH, ou=Hardware Entwicklung,
email=t.gruber@samcon.eu, c=DE
Datum: 2023.01.24 10:13:52 +01’00’
| | | |
Schillerstrasse 17, 35102 Lohra-Altenvers, Germany
www.samcon.eu
info@samcon.eu
Phone: +49 6426 9231-0
fax: – 31
References
- YouTube
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- Explosion Proof Camera Housings - IECEx and ATEX CCTV Systems
- YouTube
- YouTube
- YouTube
- How to assign an IP address and access your device
- Willkommen bei Axis Support | Axis Communications
- AXIS Q1715 Block Camera | Axis Communications
- AXIS Q1715 Block Camera - Product support | Axis Communications
- AXIS IP Utility | Axis Communications
- ExCam IPQ1715- Explosion Proof 21xoptical zoom Camera (CCTV) with fullHD resolution, ATEX, IECEx, EAC-Ex & IP66, IP68
- ExCam IPQ1715- Explosion Proof 21xoptical zoom Camera (CCTV) with fullHD resolution, ATEX, IECEx, EAC-Ex & IP66, IP68
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>