Honeywell E3Point Toxic and Combustible Gas Monitor Owner’s Manual

June 9, 2024
Honeywell

Honeywell logo E3Point Toxic and Combustible Gas Monitor
Owner’s Manual
Honeywell E3Point Toxic and Combustible Gas Monitor

E3Point Toxic and Combustible Gas Monitor

Make your operation run more intelligently to protect people, property and your bottom line

Honeywell E3Point Toxic and Combustible Gas Monitor -
FigureHoneywell E3Point Toxic and
Combustible Gas Monitor - Combustible Gas

Flexible Operation

  • Comes in standalone, standalone with remote (dual gas mode) or network versions
  • Connects to analog or digital systems
  • Works with virtually any BAS including BACnet, Modbus or LonWorks*
  • Connects to wired or wireless system (via 301CW wireless controller)
  • Wall or duct mount
  • Factory-calibrated cartridges

Cost Effective

  • Saves energy through Demand Control Ventilation (DCV)
  • Simplifies installation/maintenance through plug-n-play sensor
  • Remote sensor option provides dual gas monitoring (standalone version only)
  • Optimizes BAS, fire, ventilation and other security systems

Versatile Communications

  • Works through BAS to improve fault diagnostics and collect data on gas concentration levels, sensor condition, etc.
  • Couple with 301C to log data and daisy-chain up to 96 E³ Point units

Advanced Sensing Technology

  • Detects CO, NO2, O2, H2, H2S, CH4, C3H8
  • Advanced electrochemical (for toxic gases) and catalytic bead (for combustible gases) sensor performance
  • Uses patented Reflex® and smart cartridge technologies

Range of Accessories

  • Factory-calibrated replacement cartridges
  • Power transformer
  • Vandal-resistant steel wire detector guards
  • Tamper-proof screws
  • Horns and strobes

Electrical Certifications

  • US (ANSI/UL 61010-1)
  • Canada (CSA C22.2 No. 61010-1)
  • pending – call your sales rep for information

E³ Point goes beyond protection to offer your building greater performance and productivity.Honeywell E3Point Toxic and Combustible Gas Monitor -
performance and productivity.

Plug-N-Play Ease
E³ Point’s plug-n-play sensor is factory calibrated and works out of the box. Upon installation, E³ Point automatically configures for quick operation. You benefit from easier installation and maintenance, and greater adaptability to changing building and safety requirements.

Reflex® Keeps You Safer
Only Honeywell’s patented Reflex® technology adds this extra degree of precision and diligence to sensor monitoring to make doubly sure you’re safe. Reflex bounces  electrical signals into the E³ Point electrochemical sensor cell at regular intervals, a form of electronic bump testing and continuous monitoring of cell response.

Oscilloscope graph shows cell responding to Reflex pulse, indicating sensor condition.
Honeywell E3Point Toxic and Combustible Gas Monitor - Oscilloscope
graph GREEN
shows optimal sensor condition (dynamic responsiveness to gas).
RED shows degraded sensor condition (indicating cell dry-out or failure).
Efficient Operations + Energy Savings + Economical Value = E³ Point
Smart sensor design, extreme temperature range, etc. optimize building performance
On-demand ventilation controls energy use
Reduces cost of installation, operation and maintenance

Flexible Applications

Honeywell E3Point Toxic and Combustible Gas Monitor - Flexible
Applications

E³ Point integrates easily with your building’s analog or digital infrastructure as a standalone unit or network addressable device. Here are five installation examples to make E³ Point work for you.
E³ Point Standalone Single-Sensor Operation

A low-cost application for buildings with minimal gas monitoring requirements typical of a small facility. Offers easy installation, commissioning and operation. Two on-board
relays can activate fan or strobe.
E³ Point Standalone Dual-Gas Sensor Operation

Economical application adds option of a second (remote) sensor for dual gas monitoring. Two on-board relays can activate ventilation or strobes.
E³ Point/Wired-Wireless Hybrid ConfigurationHoneywell E3Point Toxic and
Combustible Gas Monitor - Wireless Hybrid Configuration

E³ Point offers a perfect solution for applications that require a hybrid wireless/wired system. In this configuration, E³ Point outputs signals to a controller (301CW) that also accepts signals from a wireless gas detector (301W). This scheme offers great flexibility and installation cost savings for retrofit projects. It easily handles difficult installation challenges, such as those posed by obstructions. A relay output is provided when it is desirable to activate fan/ventilation directly (e.g. when fan is located in close proximity to detector).
E³ Point/Modbus ConfigurationHoneywell E3Point Toxic and Combustible
Gas Monitor - Modbus Configuration

Supports Modbus protocol to daisy-chain E³ Point detectors, providing up to 96 points of monitoring on a serial bus. Excellent option for controller based (VA301C) installations common in larger applications. A relay output is provided as an option for activating ventilation directly (e.g. when fan is located in close proximity to detector).
E³ Point/BACnet (MS-TP) ConfigurationHoneywell E3Point Toxic and
Combustible Gas Monitor - Configuration

E³ Point outputs directly to BACnet or other BAS. Alarms, strobes and horns are activated through BAS with link to DCV/HVAC controls. This system design supports new and retrofit installations for large buildings, and can couple with a controller to effectively integrate wired and wireless system components. A relay output is provided as an option for activating ventilation directly (e.g. when fan is located in close proximity to detector).

Dual-Gas Detection In Many Combinations

Honeywell E3Point Toxic and Combustible Gas Monitor - Detection In Many
Combinations

E³ Point’s standalone, dual-gas configuration monitors two gases simultaneously and cost effectively, in any of the following combinations: toxic-toxic, toxic-combustible, oxygen-toxic, or oxygen-combustible. (The device cannot monitor two combustible gases simultaneously.)
E³ Point Expands the Range of Gas Detection to Serve Practically All Building Areas, Including Outbuildings

Building Environment Gases Present (Detected by E³ Point)
Parking Structure CO, NO2, C3H8
Loading Dock CO, NO2, C3H8,H2
Transport Terminal CO, NO2, C3H8,CH4
Golf Cart Maintenance/ Battery Charging Area CO, NO2, CH4, O2, H2
Maintenance Garage CO, NO2, C3H8, O2, H2S, H2
Hospital/Ambulance Bay CO, NO2, C3H8, O2
Fire/Police Station CO, NO2, C3H8, O2, H2, H2S
Car Wash CO, NO2, C3H8
Battery Charging Rooms & Hydrogen Tanks H2
Commercial Kitchen C3H8, CO, CH4
Indoor Stadium/Arena CH, CO, CH

Find out more
www.honeywellanalytics.com
Contact Honeywell Analytics:
Honeywell Analytics Inc.
4005 Matte Blvd., Unit G
Brossard, QC, Canada
J4Y 2P4
Tel: +1 450 619 2450
Toll free: +1 800 563 2967
Fax: +1 888 967 9938
Technical Services
ha.us.service@honeywell.com
www.honeywell.com
Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract.

H_E3Point_DS01081_V1_US 6/09
© 2009 Honeywell Analytics
Honeywell logo

Documents / Resources

| Honeywell E3Point Toxic and Combustible Gas Monitor [pdf] Owner's Manual
E3Point Toxic and Combustible Gas Monitor, E3Point, Toxic and Combustible Gas Monitor, Combustible Gas Monitor, Gas Monitor
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Honeywell User Manuals

Related Manuals