OT Wi 15/220-240/1A0 NFC CA LP I
OT Wi 25/220-240/700 NFC CA LP I
OT Wi 40/220-240/1A0 NFC CA LP I

FIG 1.JPG

FIG 2.JPG

FIG 3.JPG

FIG 4.JPG

Installing and operating information: Connect only LED load type. LED module will be switched off when output voltage is outside the voltage range given on the driver. Wiring information (see fig. A): Do not connect the outputs of two or more units. The metal surface on LED driver underside of OT Wi 40 NFC CA LP I is double insulated against mains, also the metal surface is SELV basic insulated against LED output. Output current adjustment = via programming software using Near Field Communication (NFC) in mains off mode only. For Near Field Communication (NFC) please refer to Tuner4TRONIC at www.osram.com/ds. Unit is permanently damaged if mains is applied to the terminals 21/22. Lines 21/22 max. 2 m whole length excl. modules. There are two places in the app where you can unpair a Casambi enabled device from a network. 1. Go to the ‘Luminaires’ tab and tap ‘edit’. Unpair a luminaire by tapping the (“X”) that will appear in the corner of the relevant luminaire icon. You can also double- tap a luminaire icon to open the “luminaire properties” screen, and then scroll down and tap ‘Unpair device’. 2. Go to the “Nearby devices” screen found under the ‘More’ tab. Tap on the device you wish to unpair and select ‘Unpair device’. This will unpair the luminaire if you have modification (administrator) rights to the network. If you don’t have the modification rights to the network that the device is paired to then you need to have access to the devices power switch to be able to unpair. Tap on the device you wish to unpair and select ‘Unpair device’ and the app will open the ‘Unpair’ screen. Tap on the ‘Start’ button and an orange “Time bar” will appear and start to move across the screen. During the time it takes the bar to move across the screen, flick the power switch off and back on again. This should unpair the device. If unpairing succeeds then there is a message that luminaire has been unpaired. If it does not succeed then try again but switch the power off and on again more slowly (This may be needed for devices that use an additional power supply; such as a CBU-PWM4). If unpairing continues to be unsuccessful then it is probably the case that the power switch is not correct for the device you are trying to unpair. Emergency Lighting: This LED power supply complies with EN 61347-2-13 Annex J and is suitable for emergency lighting fixtures according to EN 60598-2-22 except those used in high-risk task areas. Hereby OSRAM GmbH declares that the radio equipment types OT Wi 15 NFC CA LP I, OT Wi 25
NFC CA LP I and OT Wi 40 NFC CA LP I are in compliance with Directive 2014/53/EU and the relevant statutory instruments. The full text of the EU declaration of conformity or the UK declaration of conformity is available at the following internet address: www.osram.com/
ot-indoor-ce. Download Casambi app from App store or Google play. For the correct functioning of the Casambi app refer to the Casambi website: http://www.casambi.com. The Casambi App is provided to you by Casambi. OSRAM shall have no liability for the Casambi app and does not make any representations, express or implied, about the availability and/or performance of the Casambi app. The Casambi cloud services are provided to you by
Casambi. OSRAM shall have no liability for the Casambi cloud services and does not make any representations, express or implied, about the availability and/or performance of the Casambi cloud services. OSRAM shall have no liability for and does not make any representations, express or implied, about the
connectivity of Casambi ready products of OSRAM with any other Casambi ready products. NFC frequency range: 13 553 – 13 567 kHz; Bluetooth frequency range: 2400 – 2483.5 MHz; Max HF output power (EIRP) of the product: 8 dBm; Technical support: www.osram.com, +49 (0)89-6213-6000;

  1. Casambi ready compact LED driver for independent installation; 2) Constant current LED Power Supply; 3) wire preparation; push in; 4) tc point; 5) Made in Bulgaria; 6) picture only for reference, valid print on product; 7) Mains;
  2. Input; 9) Output; 10) Year; 11) Week; 12) Safety note for mounting with metal screw: The distance between the metal screw and the insulated single wires must be at least 2.5 mm. 13) Mounting hint for proper radio connectivity. By integrating the device into a casing the wireless range could be affected, in particular by metal surfaces. Therefore, the wireless range needs to be verified after integration. 14) Do not place any mains voltage or LED supply wires within or close to this area. 15) Recommended minimal distance to metal parts. 16) Placement of integrated radio transmitter antenna; 17) Radio frequency; 18) Wireless protocol; 19) Wireless range; 20) 10m line of sight; 21) Position; 22) Cable types (tested acc. to EN 60598-1);
  3. A or B

FIG 5.JPG