TRIPP-LITE PDUMNH30AT2 2.9kW 120V Single-Phase ATS Monitored User Manual

June 4, 2024
Tripp Lite

TRIPP-LITE PDUMNH30AT2 2.9kW 120V Single-Phase ATS Monitored
logo

TRIPP-LITE PDUMNH30AT2 2.9kW 120V Single-Phase ATS Monitored

Highlights

  • Built-in HTML5-based LX Platform interface allows you 24/7 remote access
  • Enables redundant A/B power option for single-corded network devices
  • Digital meter for real-time voltage, amp and load monitoring helps prevent overloads
  • Dual 10 ft. cords with NEMA L5-30P inputs connect to separate power sources
  • Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases

Package Includes

  • PDUMNH30AT2 2.9kW Single-Phase ATS/Monitored PDU
  • Configuration cable, USB-A to USB Micro-B
  • Rack-mounting hardware
  • (4) Cord retention brackets
  • (24) Cable ties
  • Owner’s manual

ATS PDU allows real-time current metering and remote power monitoring to help prevent circuit overloads and ensure proper load balance.

Features

Single-Phase 30A ATS PDU Distributes and Monitors Network-Grade Power in Real Time
This monitored PDU provides real-time remote monitoring of voltage, frequency and load levels via its built-in network interface. Ideal for network IT applications, small computer rooms and other equipment rack applications, the PDUMNH30AT2 features 24 NEMA 5-15/20R 120V outlets and one NEMA L5-30R outlet, which distribute AC power to rack equipment. Dual 10-foot (3.1-meter) power cords with NEMA L5-30P inputs connect to separate primary and secondary mains circuits, backup generators, UPS systems or utility power grids, including out-of-phase sources.

Switches from Primary to Secondary Power Source in Milliseconds
Dynamic solid-state automatic transfer switching (ATS) allows the PDU to switch to the secondary source within 1–5 milliseconds, should the primary source fail or become unstable, to ensure your connected equipment operates without interruption. An on-board ATS processor constantly evaluates the power quality of both input sources. It prevents switching if the secondary source is unavailable or of lower quality than the primary source.

Built-In LX Platform Network Management Card Allows Remote Access 24/7
The HTML5-based WEBCARDLX network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. The latest version of PowerAlert Device Manager (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and Tripp Lite’s PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations.

Digital LED Display and Load Meter Helps Prevent Potentially Expensive Overloads
A three-digit LED display shows measured or calculated amperage, kilowatt and voltage values at a glance. Monitoring amperage helps ensure load levels remain well below maximum capacity with no danger of overload that could lead to costly downtime or damaged equipment. Maintaining proper load levels, even while adding new equipment, can keep your TCO (total cost of ownership) low. Monitoring current provides 1% billing grade accuracy.

Mounts into 2U of Rack Space or on a Wall
Use the included mounting hardware to install the all-metal housing into 2U of space in an EIA-standard 19-inch rack. You may also use the mounting brackets to secure the PDU to a wall or under a counter. Included cord retention brackets help organize connected power cords and eliminate cable clutter.

TAA-Compliant for GSA Schedule Purchases
The PDUMNH30AT2 is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts.

Specifications


OVERVIEW


UPC Code| 037332261427
PDU Type| Auto-Transfer Switch; Monitored


INPUT

PDU Input Voltage| 120V
Recommended Electrical Service| 30A 120V
Maximum Input Amps| 30
Maximum Input Amps Details| Agency de-rated to 24A continuous
PDU Plug Type| (2) NEMA L5-30P
Input Phase| Single-Phase
Input Cord Details| Set of two inputs connect to separate PRIMARY and SECONDARY power sources
Input Cord Length (ft.)| 10
Input Cord Length (m)| 3.05


OUTPUT

Output kW Capacity (kW)| 3.05
Output Capacity Details| 3.05kW (127V), 2.88kW (120V), 2.4kW (100V) / 30A total capacity (Agency de-rated 24A); 24A max per L5-30R outlet; 20A max per breakered load bank; 16A max per 5-15/20R outlet
Frequency Compatibility| 50 / 60 Hz
Output Receptacles| (24) 5-15/20R; (1) L5-30R
Output Nominal Voltage| 100; 120; 127
Overload Protection| 2x 20A output breakers protect 12 5-15/20R outlets each


USER INTERFACE, ALERTS & CONTROLS

Front Panel LCD Display| Digital display reports output amps and kW in 4 separately metered loading segments (BANK 1: 5-20R outlets #1- 12; BANK 2: 5-20R outlets #13-24; BANK 3: L5-30R outlet #25; BANK 4: Total PDU output), whole-PDU output kW load level and input voltage on primary and secondary input lines, and IP address assignment. Temperature and/or Humidity displayed with optional Environsense2 modules
Front Panel LEDs| 2 LEDs for power status on Primary and Secondary input connection and three additional LEDs to label the displayed numeric value as Amps, kW or Voltage
Switches| ENTER and MODE switches toggle the digital display to show output amps (Banks 1-4), total kW output and input voltage (primary, secondary)
---|---


SURGE / NOISE SUPPRESSION

Automatic Shut-Off| No


PHYSICAL

Material of Construction| Metal
Form Factors Supported| 2U rackmount
Minimum Required Rack Depth (cm)| 42.93
Minimum Required Rack Depth (inches)| ****

16.9

PDU Form Factor| Horizontal (2U)
Shipping Dimensions (hwd / in.)| 7.70 x 16.60 x 19.90
Shipping Weight (kg)| 8.16
Unit Dimensions (hwd / in.)| 3.41 x 17.32 x 11.89
Unit Dimensions (hwd / cm)| 8.66 x 44 x 30.2
Unit Weight (lbs.)| 13.71
Unit Weight (kg)| 6.22


ENVIRONMENTAL

Operating Temperature Range| 0C ~ 40C (32F ~ 104F)
Storage Temperature Range| -30°C to +50°C (-22°F to +122°F)
Relative Humidity| 5-95% noncondensing
Operating Elevation (ft.)| 0-10,000
Operating Elevation (m)| 0-3000


COMMUNICATIONS

PowerAlert Software| LX Platform Interface: PowerAlert Device Manager
Communications Cable| Micro-USB- to-USB A configuration/console Access cable
Network Monitoring Port| RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules.
SNMP Compatibility| n/a
Network Compatibility| 10 Mbps; 100 Mbps (Fast Ethernet)


FEATURES & SPECIFICATIONS

TVSS Grounding| Rear grounding lug
High Availability PDU Features| Auto-Transfer Switching


STANDARDS & COMPLIANCE


Certification & Compliance| UL 62368-1; CSA (Canada); FCC Part 15 Class A (USA); NOM (Mexico); RETIE (Colombia); RoHS


WARRANTY

Product Warranty Period (Worldwide)| ****

2-year limited warranty

© 2022 Tripp Lite. All rights reserved. All product and company names are trademarks or registered trademarks of their respective holders. Use of them does not imply any affiliation with or endorsement by them. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice. Tripp Lite uses primary and third-party agencies to test its products for compliance with standards. See a list of Tripp Lite’s testing agencies:
https://www.tripplite.com/products/product-certification-agencies

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Tripp Lite User Manuals

Related Manuals