Wilo-Stratos ECO
Installation and operating instructions
Stratos ECO Industrial Pump
Fig.1:
|
Fig.2:
---|---
Fig.3:
|
Fig.4:
General
1.1 About this document
These installation and operating instructions are an integral part of the
product. They must be kept readily available at the place where the product is
installed. Strict adherence to these instructions is a precondition for the
proper use and correct operation of the product.
This installation and operating instructions conform to the relevant version
of the product and the underlying safety standards valid at the time of going
to press.
Safety
These instructions contain important information which must be followed when
installing and operating the pump. It is therefore imperative that they be
read by both the installer and the operator before the pump is installed or
operated. Both the general safety instructions in this section and the more
specific safety points in the following sections should be observed.
2.1 Instruction symbols used in this operating manual
Symbols:
| General danger symbol
---|---
| Hazards from electrical causes
| NOTE: …
Installation and operating instructions Wilo-Stratos ECO
Signal words:
DANGER!
Imminently hazardous situation.
Will result in death or serious injury if not avoided.
WARNING!
Risk of (serious) injury. ‘Warning’ implies that failure to comply with the
safety instructions is likely to result in (severe) personal injury.
CAUTION!
Risk of damage to the pump/installation. ‘Caution’ alerts the user to
potential product damage due to non-compliance with the safety instructions
NOTE:
Useful information on the handling of the product. It alerts the user to
potential difficulties
2.2 Personnel qualification
The personnel installing the pump must have the appropriate qualification for
this work.
2.3 Risks incurred by failure to comply with the safety instructions
Failure to comply with the safety precautions could result in personal injury
or damage to the pump or installation. Failure to comply with the safety
precautions could also invalidate any claim for damages.
In particular, failure to comply with these safety instructions could give
rise, for example, to the following risks:
- Failure of important pump or system functions,
- Personal injury due to electrical and mechanical causes.
2.4 Safety instructions for the operator
The relevant accident precaution regulations must be observed.
Potential dangers caused by electrical energy must be excluded. Local or
general regulations [e.g. IEC, BSI, UL, etc.] and directives from local energy
supply companies are to be followed.
2.5 Safety instructions for inspection and assembly
The operator must ensure that all inspection and assembly work is carried out
by authorized and qualified specialists who have carefully studied these
instructions. Work on a pump or installation should only be carried out once
the latter has been brought to a standstill.
2.6 Unauthorised modification and manufacture of spare parts
Changes to the pump/machinery may only be made in agreement with the
manufacturer. The use of original spare parts and accessories authorized by
the manufacturer will ensure safety. The use of any other parts may invalidate
claims invoking the liability of the manufacturer for any consequences.
2.7 Improper use
The operating safety of the pump or installation can only be guaranteed if it
is used in accordance with paragraph 4 of the operating instructions. All
values must neither exceed nor fall below the limit values given in the
catalog or data sheet.
Transport and interim storage
Inspect the pump/system for transport damage immediately upon arrival. Any
transport damage found must be reported to the carrier within the prescribed
periods.
CAUTION! Risk of damage to the pump!
Risk of damage due to improper handling during transport or storage.
- The pump is to be protected against moisture and mechanical damage due to impact/shock.
- The pumps must not be exposed to temperatures outside the range -of 10°C to +50°C.
Applications
Stratos ECO:
WARNING! Health hazard!
The pump must not be used for pumping liquids in the fields of
service/drinking water and food-related liquids.
Series Wilo-Stratos ECO circulating pumps are intended for use in conjunction
with hot water heating or similar water circulating systems of variable volume
characteristics. The pump-integrated electronic differential pressure control
provides infinitely-variable speed control to match pump capacity to actual
load demand.
Stratos ECO-Z:
Series Wilo-Stratos ECO-Z circulating pumps are also suitable for handling
liquids in the fields of service/drinking water and food-related liquids.
Product data
| Stratos ECO 25(30)/1-3| Stratos ECO 25(30)/1-5| Stratos ECO-Z 25/1-5
---|---|---|---
Mains Power| 1~ 230 V ± 10%, 50 Hz
Max. power input P1 max| refer to name plate data
Max. Speed| refer to name plate data
Degree of protection IP| 44
Water temperature range| from +15°C to +110°C
Service water temperature for
Stratos ECO-Z 25/1-5| from +15°C
to +110°C
Max. working pressure| 10 bar
Max. ambient temperature| +40°C
Inf. variable head control| 1-3m| 1-5m| 1-5m
Minimum static inlet pressure| 0,3 bar / 1,0 bar
for Tmax| +95°C / +110°C
Pipe connection size| Rp 1 (1¼)
Port-to-port dimension| 180 mm, 130 mm
- Water temperature range max. 110 °C at ambient temperature max. 25 °C
max. 95 °C at ambient temperature max. 40 °C
5.2 Suitable fluids:
- Heating water acc. to VDI 2035,
- water and water/glycol mixtures up to a 1:1 ratio. The use of glycol mixtures requires a reassessment of the pump hydraulic data in line with the increased viscosity at the various mixing ratios. Only approved makes of additives with corrosion inhibitors must be used in strict compliance with manufacturers’ instructions.
- For the use of other fluids contact Wilo first.
5.3 Scope of supply
- Circulating pump, complete,
- Installation and operating instructions.
Description and operation
6.1 Pump description
Pump (Fig 1)
The circulating pump is fitted with a wet (canned rotor) motor.
The circulating water service pump Stratos ECO-Z 25/1-5 is specially designed
for use in conjunction with domestic/ drinking water service systems. It is by
material selection and design, corrosion proofed against any residual, parts
in domestic/drinking water.
For thermal insulation, the pump housing is lagged with an insulation shell.
The motor housing is with an electronic control model (Item 1) capable of
maintaining the pump-generated differential pressure constant at a preset
value between 1 and 3 m, or 1 and 5 m. Pump capacity is thus matched to the
changing load demand which is particularly significant when using thermostatic
control valves.
The essential advantages and benefits are:
- no bypass relief valves are required,
- power savings,
- reduction of flow noise.
Control mode (Fig 2):
Variable differential pressure (Δp-v): The differential pressure setpoint
levels are proportionally increased between ½H and H over the permissible flow
range. The pump-generated differential pressure will thus be controlled to the
respective level.
The pump automatically responds to the night setback of the central heating
installation by electronic evaluation from a temperature sensor. The pump will
then switch to the minimum speed. On renewed boiler heat up the pump will
switch back to the previously adjusted setpoint level. The night setback
control can be switched off (Fig. 1, Item 2):
- auto: Night setback ON, control operation to the preselected setpoint value, and automatic, temperature-activated night setback (additional power savings).
- : Night setback OFF, control operation to the preselected setpoint value.
Factory setting: Night setback OFF.
NOTE:
In the case of insufficient heating/cooling capacity of the installation (too
low a heat transfer), it must be checked whether the night setback control is
on. In this case, it must be
switched off.
Operating elements (Fig 1):
- Dial knob for the differential pressure setpoint (Fig. 1, Item 2).
- Setting range:
- Stratos ECO 25(30)/1-3: Human = 1 m, Hmax = 3 m
- Stratos ECO 25(30)/1-5: Human = 1 m, Hmax = 5 m
- Stratos ECO-Z 25/1-5: Hmin = 1 m, Hmax = 5 m
Installation and electrical connection
Installation and electrical connection should be carried out in accordance
with local regulations and only by qualified personnel!
WARNING! Risk of personal injury!
The relevant accident precaution regulations must be observed.
WARNING! Risk of electric shock!
Potential dangers caused by electrical energy must be excluded.
Local or general regulations [e.g. IEC etc.] and directives from local energy
supply companies are to be followed.
7.1 Installation
- Install the pump only after completion of all welding/soldering and after the pipe system had been thoroughly flushed out.
- Mount the pump in an easily accessible location in order to facilitate later inspections or exchanges.
- When installed in the flow pipe of an open-vented system, the safety vent must be connected to the inlet side of the pump.
- Isolating valves should be provided and installed at both the suction and discharge ports of the pump in order to facilitate a possible pump exchange. They must be located in such a way as to prevent valve spindle leakage from spilling onto the control module (upper valve turned sideways).
- Install the pump free of stress and with the motor shaft horizontally located. For module, locations refer to Fig. 3. Other arrangements on request.
- Directional arrows on the pump body and the insulation shell indicate the direction of flow.
- If the mounting location of the module is to be altered, turn the motor housing as follows:
- Unclip the insulation shell with the aid of a screwdriver and remove it,
- undo the 2 Allen screws,
- and turn the motor housing including the control module.
CAUTION! Risk of damage to the pump!
When turning on the motor housing the gasket may be damaged. Replace damaged
gaskets immediately.
Size of gasket: ∅86 mm OD x ∅76 mm ID x2,0 mm thick, EP.
- Reset and fix Allen screws,
- and refit the insulation shell.
7.2 Electrical connection
WARNING! Risk of electric shock!
Electrical connection must be carried out by an electrical installer
authorized by the local power supply company in accordance with the applicable
local regulations.
- The power supply must correspond to name plate data.
- Power wiring to be in accordance with Fig. 4:
- power connections: L, N, PE.
- max. line fuse: 10 A, slow action.
- The connecting cable can optionally be lead through the cable gland on either the right or left. The gland and the blank plug (PG 11) must then be changed.
- Strictly comply with local earthing regulations.
- All wiring and external switchgear to comply with local regulations (use of conduits, switch air gaps, and pole switches) in strict accordance with locally ruling regulations.
- The incoming power cable must be sufficiently large sized to maintain protection from moisture ingress and to ensure a tight gland grip (e.g. H05W-F3G1,5 or AVMH-3×1,5).
- Heat-resisting cable must be used when installing the pump in systems with water temperatures above 90°C.
- Cable leads are to be routed to avoid any contact with the adjoining pipework and/or the pump or motor housings.
Starting-up
WARNING! Risk of burning!
Note the acute danger of the pump becoming very hot, depending on the
operating conditions of the pump or system respectively (fluid temperature).
The danger of burning when touching the pump!
8.1 Initial start-up
Ensure that the pipe system is properly filled and air-vented.
The pump rotor space is automatically vented after a short running period.
Short-term dry running will not do harm to the pump. If, however, manual
venting of the pump may
become necessary (not apply to the air-venting pump) the following procedure
is to be adopted:
- switch-off pump,
- close discharge isolating valve,
WARNING! Risk of scalding!
Depending on fluid temperature and system pressure there is the possibility of
hot water in a liquid or gaseous state suddenly erupting under great force
when opening the vent plug. Note the severe danger of scalding!
- break through the perforation, centrically the nameplate and open the vent screw carefully,
- protect electrical parts from released water,
- carefully move and push the pump shaft with a screwdriver,
CAUTION! Risk of damage to the pump!
There is the possibility, depending on the system pressure, of the pump
jamming with the vent plug open. Before switching on the pump refit and
tighten the vent plug.
- refit and tighten the vent plug,
- reopen the discharge valve,
- and switch on the pump.
8.2 Adjusting the pump capacity
- Select desired control mode (refer to chapter 6.1).
- Preselect pump capacity (head) at the dial button according to requirements (Fig. 1, Item 2).
- If head requirements are not known it is recommended to begin with a 1,5 m setting.
- If the heating capacity proves insufficient increase head setting step by step.
- Reduce heat setting step by step if the heating capacity is too high or noise generation is excessive.
- Select night setback mode; switch either to On or Off (refer to chapter 6.1).
Maintenance
Maintenance and repair work should only be carried out by qualified personnel!
WARNING! Risk of electric shock!
Potential dangers caused by electrical energy must be excluded.
- The pump must be switched off for all repair work and secured against unauthorized operation.
- In principle, damage to the connecting cable should only be repaired by a qualified electrician.
Problems, causes, and remedies
The pump is switched-on but does not run:
- check electrical fuses,
- check voltage available at the pump (note nameplate data),
- Locked rotor:
- switch off the pump,
WARNING! Risk of scalding!
Depending on fluid temperature and system pressure there is the possibility of
hot water in a liquid or gaseous state suddenly erupting under great force
when opening the vent plug. Note the severe danger of scalding!
- close isolating valves at both pump ports and let the pump cool down. Remove the vent plug, check the freedom of rotation and relock pump rotor by turning the shaft at its slotted end with the aid of a screwdriver
- switch on the pump.
- Should the blockage not be automatically resolved via the automatic deblocking system, please consult the manual procedural instructions as described above.
Noisy pump operation
-
checks differential pressure setting and adjust them respectively.
-
Heating capacity too low, possibilities to increase:
-
Stepp-up setpoint value,
-
switch off night setback,
To briefly switch off night setback mode (check on control operations) it is sufficient to just turn the dial button a little. -
On cavitation, increase system pressure within the permissible limit.
If no solution can be found, please contact your plumbing and heating specialist or your nearest Wilo Customer Service representative.
Spare parts
Spare parts are ordered via a local specialist dealer and/or Wilo customer
service.
In order to avoid queries and incorrect orders, make sure to mention all data
indicated on the rating plate when placing your order.
Subject to technical alterations!
EC – Declaration of conformity
(gemäß 2004/108/EG Anhang IV,2 und 2006/95/EG Anhang III,B,
according to 2004/108/EC annex IV,2 and 2006/95/EC annex III, B,
conforme 2004/108/CE appendice IV,2 et 2006/95/CE appendice III B)
Herewith, we declare that this product:
Stratos ECO
Stratos ECO Z
Stratos ECO L
Stratos ECO ST
Stratos ECO BMS
in its delivered state complies with the following relevant provisions:
Electromagnetic compatibility – directive – 2004/108/EG
Low voltage directive – 2006/95/EG
and with the relevant national legislation.
Applied harmonized standards, in particular: EN 6035-2-51, EN 61000-6-2, EN
61000-6-3
If the above-mentioned series are technically modified without our approval,
this declaration shall no longer be applicable.
Dortmund, 20.05.2010 WILO SE
Nortkirchenstraße 100
44263 Dortmund
Germany
Document: 2109722.1
Wilo – International (Subsidiaries)
Canada
WILO Canada Inc.
Calgary, Alberta T2A 5L4
T +1 403 2769456
bill.lowe@wilo-na.com| Croatia
WILO Hrvatska d.o.o.
10090 Zagreb
T +38 51 3430914
wilo-hrvatska@wilo.hr
---|---
Denmark
WILO Danmark A/S
2690 Karlslunde
T +45 70 253312
wilo@wilo.dk| Finland
WILO Finland OY
02330 Espoo
T +358 207401540
wilo@wilo.fi
Great Britain
WILO (U.K.) Ltd.
DE14 2WJ BurtonUpon-Trent
T +44 1283
523000
sales@wilo.co.uk| Ireland
WILO Engineering Ltd.
Limerick
T +353 61 227566
sales@wilo.ie
Switzerland
EMB Pumpen AG
4310 Rheinfelden
T +41 61 8368020
info@emb-pumpen.ch| USA
WILO-EMU USA LLC
Thomasville,
Georgia 31792
T +1 229 5840097
info@wilo-emu.com
USA
WILO USA LLC
Melrose Park, Illinois 60160
T +1 708 3389456
mike.easterley@wilo-na.com| Poland
WILO Polska Sp. z.o.o.
05-090 Raszyn
T +48 22 7026161
wilo@wilo.pl
Wilo – International (Representation offices)
Algeria
Bad Ezzouar, Dar El Beida
T +213 21 247979
chabane.hamdad@salmson.fr| Bosnia
and Herzegovina
71000 Sarajevo
T +387 33 714510
zeljko.cvjetkovic@wilo.ba
---|---
Armenia
375001 Yerevan
T +374 10 544336
info@wilo.am| Georgia
0177 Tbilisi
T +995 32317813
info@wilo.ge
Wilo-Vertriebsbüros
G1 Nord
WILO AG
Vertriebsbüro Hamburg
Beim Strohhause 27
20097 Hamburg
T 040 5559490
F 040 55594949
hamburg.anfragen@wilo.de| G2 Ost
WILO AG
Vertriebsbüro Berlin
Juliusstraße 52–53
12051 Berlin-Neukölln
T 030 6289370
F 030 62893770
berlin.anfragen@wilo.de
---|---
G7 West
WILO AG
Vertriebsbüro Düsseldorf
Westring 19
40721 Hilden
T 02103 90920
F 02103 909215
duesseldorf.anfragen@wilo.de|
G6 Rhein-Main
WILO AG
Vertriebsbüro Frankfurt
A den Drei Hasen 31
61440 Oberursel/Ts.
T 06171 70460
F 06171 704665
frankfurt.anfragen@wilo.de
Kompetenz-Team Kommune Bau + Bergbau
WILO EMU GmbH Heimgartenstraße 1
95030 Hof
T 09281 974-550
F 09281 974-551
Stand Januar 2008
WILO SE
Nortkirchenstraße 100
44263 Dortmund
Germany
T 0231 4102-0
F 0231 4102-7363
wilo@wilo.com
www.wilo.de
4 131 020-Ed. 02 / 2010-06-Wilo
References
- E-MU - Home
- Commercial Distributor & Supply Company | North American
- crisol.ch – Crisol Holding GmbH
- Pump & Pump System Manufacturers | Wilo
- Wilo Corporate - Pioneering for You | Wilo
- Wilo - Premiumanbieter von Pumpen und Pumpensystemen | Wilo
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>