ABUS PR1400 Door Bar User Manual

June 9, 2024
ABUS

PR1400

Door bar

Thank you for choosing this ABUS product!
Please read this guide carefully before installation and use.
Keep these instructions and provide all users with instruction on how to use it.
Possible uses and important information
Suitable for all rebated doors and flush doors that open inwards*, DIN right hinged and left hinged, door leaf widths of 850 mm – 1.000 mm.

  • With the mounting set PA1014 the door bar PR1400 can also be mounted on doors opening outwards (separately available as accessories).
    According to the situation of the installation, the possibility to fasten the lock may be restricted and has to be checked individually.

ABUS PR1400 Door Bar-

Installation

Hold the fastening shackle next to the door edge (fig. 1), mark drill positions (a) and pre-drill: wood Ø 3,5 mm, metal Ø 4,0 mm (fig. 2). Screw down with the inserted metal distance plate (screws 4,8 x 32 mm, fig. 3a). In case of flush doors line with a 5 mm spacer (fig. 3b). Depending on the possibilities to screw, the fastening shackle can also be screwed down with the chamfered side to the door edge. Itshould be taken into consideration that the shackle must snap back at least 5 mm from the door edge (fig. 3c). Insert the bolt case. The side of the bolt which is completely pushed is pointing to the door lock. Adjust it horizontally, hold on the rear fastening shackle and mark the drill position. The distance from the pushed-in bolt to the hinge must be at least 40 mm (fig. 4). Remove the bolt case, pre-drill the screwdown holes (a): wood 3,5 mm, metal 4,0 mm). Screw down the fastening shackle with the inserted intermediate metal plate (screws 4,8 x 32 mm, fig. 5). In case of flush doors line with a 5 mm spacer (fig. 3b). Insert the bolt case into the two fastening shackles. The visible bolt is pointing to the hinge side. Use a grub screw to wedge it slightly from the top (fig. 6).

ABUS PR1400 Door Bar-fig1

Press in the red handle plates both on top and bottom, then push out the bolt. For door leaf widths of more than 860 mm, the bolt must be adjusted on the hinge side of the door by 1 to 9 divisions (1 division = 19 mm). Depending to the position of the lock case on the lock side or in case of a narrow recess, push in or out the shorter bolt by 1 division. Adjustment of the bolt: Remove the bolt case. Press in the red handle plates of the bar and hold them (fig. 7).

ABUS PR1400 Door Bar-fig2

Attention: Do not let go of the handle plates! When letting go of the red handle plates while adjusting, the springs might come out!
Adjust bolt by the divisions needed and screw on tight the bar. The screws will cut the threading on their own (fig. 8).
Re-insert bolt case into both fastening shackles and fix with grub screws (Abb. 6). (For fitting in recesses see last point)
Push locking case onto the pushed-out bolts. The hole marking points away from the PR1400. Line with plastic spacers, if necessary (fig. 9).
Determine required position. Distance of locking case to the door edge on the hinge side must be at least 20 mm (fig. 10).
Push back bolt, mark 4 drill holes (b) and pre-drill: wood Ø 3,5 mm, metal Ø 4,0 mm, stone Ø 8,0 mm – and fix tight with 4 screws (4,8 x 60 mm).
When fitting on the wall additionally use frame dowels. Drill at an angle (c) through the locking case into the wall pointing at little upwards and downwards, Ø 10 mm and about 140 mm deep (fig. 11).
Insert screw into the dowel, push both into the dowel hole up to the dowel collar and tighten the screw firmly. Attention: To open the door push back both bolts.
Fitting in narrow areas: In case it is not possible to fix the locking case, push out bolt to the wall and mark the bolt profile. Stem out the bolt opening and fix the strike firmly in the masonry (fig. 12). Push in bolt until secure fit is ensured and the bolt engages.

Operation

Opening and closing is done exclusively via the two red push buttons.

Disposal
At the end of its service life, dispose of the product in accordance with the applicable legal requirements. Dispose of the packaging according to type. Separate the cardboard,
foil and plastic elements for recycling. Please contact the local authority responsible for disposal if you have any queries.

Warranty

ABUS products are designed, manufactured and tested in accordance with applicable regulations with great care. The warranty exclusively covers faults that are caused by material or manufacturing defects. If a material or manufacturing defect can be proven, the product will be repaired or replaced at the discretion of the warrantor. In such cases, the warranty ends with the termination of the original war- ranty period. Any further claims are expressly excluded. ABUS assumes no liability for defects or damage that has been caused by external influences (e.g. transport, external forces), improper use, normal wear and tear or non-compliance with this operating and installation instructions document. If a warranty claim is asserted, the product must be returned with the original receipt with date of purchase and a brief written description of the fault. Subject to technical alterations. No liability for mistakes and printing errors.

© ABUS 2022
ABUS August Bremicker Sohne KG
D 58292 Wetter I Germany.
Tel.: +49 (0) 23 35 63 40
www.abus.com I info@abus.de
T390740 | V1 | D22

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals