AZBW10120 Motion Detector PIR MW
User Guide
Disassembling the Detector
1 | Lens |
---|---|
2 | LED Light Pipe |
3 | Lens holder |
4 | PCB |
5 | Nut |
6 | Casing Screw |
Printed Circuit Board (PCB)
1 | PIR Sensor |
---|---|
2 | AND/OR Mode |
OR is non EN compliant
3| 50Hz as default
60Hz remove header
4| Microwave Module
5| Tamper Resistor Headers
6| Terminals
7| Alarm Resistor Headers
8| Tamper Spring
9| LED ON/OFF
LED ON
LED OFF
10| Sensitivity Settings
LOW
AUTO (DEFAULT)
HIGH
Installation
Detector Backplane Installation
Screw Model: PA_3.5 ×25
Number: 4
Installation Hints
The Lens
A| Detection Range
85.9°
52 zones
4 planes
---|---
B| Mounting height range from 1.8 m to 2.4 m. The recommended mounting height
is 2.2 m.
Note: PET immunity is available up to 10 m and at a height that is below the
top plane of view
C| Microwave Range Control
Max: 12 m
Medium: 0 to 8 m
Min: Off
D| To use the pet immunity function, please install a pet mask.
Pet Table
| Sensitivity mode High| Weight
---|---
High| 5 kg
Auto| 10 kg
Low| 15 kg
Resistor Wiring
The detector has two methods for resistor wiring:
- Use headers to select the End of Line resistance (Control panel dependent) on the ALARM/TAMPER header pins.
- Select a resistance (Control panel dependent), and add the resistor to the ALARM/TAMPER wiring ports of the detector.
Note: If EOL (End of Line) wiring is not used, leave the headers OFF. If the headers and the header pins do not match, do not force the header, please select method 2 to wire the resistor. Method 1 and method 2 should not be used on the ALARM/TAMPER at the same time.
Choose the Connection Type
- Normally Closed
A| Alarm Control Panel
---|---
B| Detector - Single End of Line Wiring
The connection shows the example:
1. Normal: 1K
2. Alarm: Infinite
3. Tamper: 0 KA| Alarm Control Panel
---|---
B| Detector - Double End of Line Wiring
The connection shows the example:
1. Normal: 1K
2. Alarm: 2K
3. Tamper: 0 K or infinite
A | Alarm Control Panel |
---|---|
B | Detector |
Powering up
Powering up:
Aft er powering on, the indicator flashes rapidly. Once the detector self-test
is completed, the LED indicator will go out until the detector detects
movement
Dimension and Weight
Technical Specification
Detection range | 12m, 85.9° |
---|---|
Detection speed | 0.3 ~ 2 m/s |
Sensitivity | High, Auto, Low* |
Auto sensitivity | Yes |
Onboard EOL | Yes |
Digital temperature compensation | Yes |
Technology | Digital microprocessor-based |
Sealed optics | Yes |
Creep zone protection | Yes |
Tamper protection | Front |
LED indicators | Green(PIR), Orange(microwave), Blue(alarm) |
Microwave frequency | 24Ghz (24.15Ghz to 24.25Ghz) |
Microwave range | Potentiometer adjustment |
Microwave transmission power | max. 18.6 mW |
AND/OR mode | AND = PIR + MW |
OR = PIR / MW (shouldn’t be used with pets)
Pet immunity| 10Kg (With optional pet mask)
Power supply| 9 to 16 VDC (standard: 12 VDC)
Current consumption| 17mA quiescent and maximum at12V DC
Operating temperature| -10 °C to 40 °C (14 °F to 104 °F)
Storage temperature| -20 °C to 60 °C (-4 °F to 140 °F)
Operating humidity| 10% to 90%
Mounting height| 1.8 – 2.4m
Dimensions (HxWxD)| 103.8 mm × 65.7 mm × 45.5 mm
Weight| 99 g
- Low is non-EN and non INSERT compliant.
DECLARATION OF CONFORMITY
ABUS Security-Center hereby declares that the enclosed product(s) comply with
the requirements of the following directives: EMC Directive (2014/30/EU) and
RoHS Directive (2011/65/EU). The full EU Declaration of Conformity text can be
found at:
www.abus.com/product/AZBW10120 It can
also be obtained at the following address:
ABUS Security Center
GmbH & Co. KG, Linker Kreuthweg 5,
86444 Affi ng, GERMANY
Subject to technical modifications and color changes. No liability is assumed
for mistakes or printing errors.
EN 50131-1:2006+A1:
2009+A2:2017
EN 50131-2-4:2008
Security Grade (SG) 2
Environmental Class (EC) II
ABUS Security-Center GmbH & Co. KG