OSRAM DULUX D/E LED User Manual
- June 9, 2024
- OSRAM
Table of Contents
OSRAM DULUX D/E LED User Manual
Dimension
OSRAM DULUX® D/E LED is suitable for 4pin G24q-1, G24q-2 and G24q-3 base:
Electronic Ballast (ECG). Please check our latest ECG compatibility list at
www.ledvance.com/ ecg-compatibility. Not for use
with CCG*
OSRAM DULUX ® D/E LED| Replacement of conventional compact
fluorescent lamp on ECG¹ )| Maximum case temperature² ) (Tc)
at Ta max (50°C)| Ambient temperature³ ) (Ta)| Storage
temperature 4) (Ts)
---|---|---|---|---
DULUX D/E 13 LED 7 W 830/840 230V HF G24q-1| 13 W| 80 °C| -20 °C … 50
°C| -20 °C … 80 °C
DULUX D/E 18 LED 7 W 830/840 230V HF G24q-2| 18 W| 85 °C
DULUX D/E 26 LED 10 W 830/840 230V HF G24q-3| 26 W| 85 °C
OSRAM DULUX® D/E LED is suitable for 4pin G24q-1, G24q-2 and G24q-3 base: Electronic Ballast (ECG). Please check our latest ECG compatibility list at www.ledvance.com/ecgcompatibility. Not for use with CCG.
Instruction
The compatibility list is based upon testing conducted by the manufacturer in a la simulated environment, and the results can vary in certain field applications due to a number of factors. LEDVANCE does not take over any responsibility, warranty or liability that this results can also achieved by using the devices under other conditions, or when using successor models of the tested devices, or different models of the same manufacturer. In case of nonobservance of the instructions, safety risks like overheating of OSRAM DULUX® D/E LED or ECG may oc ur in rare cases. Luminous flux will change in dependency of used ballast. This lamp is designed for general lighting service (excluding for example explosive atmospheres). This lamp may not be suitable for use in all applications where a traditional compact fluorescent lamp has been used. The temperature range of this lamp is more restricted. Tc point is located below the LED module on the back side of the lamp. In case of multi- lamp luminaire application measure tc Max temperature of all installed lamps. Please use a flexible the mosensor (e.g. “Type K”) and fix it on the tc point. LED lamps operated above tc max can lead to premature aging and failure of the devices. In cases of doubt regarding the suitability of the application the manufacturer of this lamp should be consulted.
- Replacement of conventional compact fluorescent lamp on ECG.
- Maximum case temperature.
- Ambient temperature.
- Storage temperature.
- Lamp to be used in dry conditions or in a luminaire that provides protection.
- Lamp suitable for high frequency operation.
- Lamp not suitable for emergency operation.
- Dimming not allowed.
Symbols
-
Lamp to be used in dry conditions or in a luminaire that provides protection5)
-
Lamp suitable for high frequency operation6)
-
Lamp not suitable for emergency operation7)
-
Dimming not allowed8)
LEDVANCE GmbH
Steinerne Furt 62
86167 Augsburg, Germany
www.ledvance.com