GROWATT MIN 2500-6000TL-X Compact Inverters User Guide
- June 9, 2024
- Growatt
Table of Contents
GROWATT MIN 2500-6000TL-X Compact Inverters
Overview
- Front panel
- Touch button
- OLED screen
- LED indicator
- DRM port
- Heat sink
- DC switch
- PV terminal
- RS485 port
- Vent valve
- USB port
- AC terminal
Note
- This document is for quick installation guidance only, please refer to User Manual for more details.
- Growatt shall not be liable for any damage resulting from unproper installation.
Installation
System overview
Installation requirements
Wall mounting
Note
- When drilling holes in the wall, avoid water and electricity pipes, otherwise it may cause danger.
Communication module installation
Electrical connection
Please prepare the cable before connecting as follows.
Grounding
AC output connection
DC connection
PV input terminal installation
Please make sure the cable can not be pulled out after pressing.
Pull the PV cable make sure there is no loose or shaking.
Make sure the cable polarity is correct and voltage is less than 550V.
Plug in PV terminal
Note:
- Before installing the PV terminal, please double-check that the PV input voltage and current do not exceed the MPPT limits.
- When installing the PV terminal, pay attention to the difference between the positive and negative poles and the one-toone correspondence between the terminals and the machine.
- There is a “click” sound when the terminal is connected,please gently pulling the PV wire to make sure there is no loose or pulling off.
Communication cable installation
Note
- When laying out signal cables, separate them from power cables to avoid strong signal interference sources
- Do not mix the connector to the DRM COM port and the connector to the SYS port.
SYS COM Port Pin Definitions
DRM Port Pin Definitions
Note
- When laying out signal cables, separate them from power cables to avoid strong signal interference sources
- Do not mix the connector to the DRM COM port and the connector to the SYS port.
Connecting Meter
The following table describes how we can connect EASTRON meter (SDM230-Modbus)to inverter:
The following table describes how we can connect CHINT meter (DDSU666) to inverter
Note: For Australian market,installers can connect pin3 or pin4 to the neutral links/bars.
Post-installation check
Power on and off steps
Note
Before turning the inverter on, please make sure the PV input voltage and current are within the MPPT limits. Follow the steps below to turn the inverter on:
- Switch on the build- in DC isolator at the bottom of the inverter.
- Switch on the PV Array and DC isolator next to your inverter, if you can not find this switch, skip this step.
- Switch on the Solar AC isolator if the inverter is more than 3 meters away from your switchboard.
- Switch on the solar supply main switch in the switch board.
Status of PV grid inverter
Customer can read more information by push button.
Export limitation setting