Miele H2890B Electric Built-In Oven Installation Guide
- June 9, 2024
- Miele
Table of Contents
Miele H2890B Electric Built-In Oven
Installation
Building-in dimensions
Dimensions are given in mm.
Installation in a tall or base unit
When building the oven into a base unit underneath a cooktop, please also
observe the installation instructions for the cooktop as well as the building-
in height required for the cooktop.
The HAL 90 trim, available as an optional accessory, is only required when building the oven into a base unit.
Tall unit side view
Base unit side view
The HAL 90 trim is available as an optional accessory.
- Fix the HAL trim into the unit cut-out under the worktop.
Connections and ventilation
- Front view
- Mains connection cable, length = 2,000 mm
- No connections permitted in this area
- Ventilation cut-out, min. 150 cm²
Installing the oven
For safety reasons, the oven may only be used after it has been fully
installed.
The oven requires a sufficient supply of cool air for efficient operation. The
required supply of cool air must not be excessively heated by other heat
sources (e.g. solid fuel stoves).
The following must be observed when installing the appliance:
Make sure that the shelf that the oven sits on does not touch the wall.
Do not fit heat insulation strips to the side walls of the housing unit.
- Connect the mains cable from the oven to the electricity supply.
Do not carry the oven by the door handle. The door can be damaged.
Use the handle cut-outs on the side of the housing to lift the appliance.
It is a good idea to remove the door (see “Cleaning and care – Removing the door”) and the accessories before installing the appliance. This makes the oven lighter when you push it into the housing unit and you do not run the risk of lifting it by the door handle by mistake.
- Remove the carry handles.
- Push the oven into the housing unit and align it.
- Open the door, if you have not removed it.
- Use the screws supplied to secure the oven to the side walls of the housing unit.
- Refit the door, if necessary (see “Cleaning and care – Fitting the door”).
Electrical connection
Danger of injury!
Miele cannot be held liable for unauthorized installation, maintenance and
repair work as this can be dangerous to users.
Connection to the electrical mains may only be carried out by a qualified electrician in accordance with national and local regulations and the additional regulations of the local electrical supply companies.
Connection of this appliance must comply with national and local safety regulations.
Connection to a switched socket is recommended as this provides easier access
in the case of a service call.
If the appliance is hardwired or if the switch is not accessible after
installation, an additional means of disconnection must be provided for all
poles. Suitable means of disconnection include switches with an all-pole
contact gap of at least 3 mm.
These include isolator switches, fuses and relays in accordance with the
wiring rules AS/NZS 3000.
Voltage, rated load and fuse rating are given on the data plate situated at
the front of the oven compartment.
Please ensure the connection data matches the household supply.
When contacting Miele, please quote the following:
- Model number
- Serial number
- Connection data (voltage/frequency/maximum rated load)
If the mains connection cable is damaged, it must be replaced by a suitably qualified electrician with a specialist connection cable of type H 05 VV-F, available from Miele, in order to avoid a hazard.
Temporary or permanent operation with a self-sufficient or non-mains
synchronous energy supply system (e.g. isolated networks, back-up systems) is
possible. A requirement for the operation is that the energy supply system
complies with all current local and national requirements that apply to stand-
alone, solar and/or battery systems.
The protective measures provided in the domestic installation and in this
Miele product must also be assured in their function and operation in isolated
operation or in non-mains synchronous operation, or replaced with equivalent
measures in the installation.
Oven
This oven is supplied with an approx. 2 m long 3-core cable for connection to
a single-phase supply.
Maximum rated load: see data plate.
Wiring diagram
Read User Manual Online (PDF format)