HAYWARD HP55TR Trevinium Swimming Pool Heat Pump Unit Instruction Manual

June 9, 2024
Hayward

REV 2017-1
TREVINIUM by Hayward
SWIMMING POOL HEAT PUMP UNIT
Installation & Instruction Manual  Model
HP55TR HP7STR

USER INTERFACE

General presentation
The heat pump is equipped with a digital control panel with a touch screen, electronically connected and pre-set at the factory in heating mode.

Legend

1 On/Off 12 Timers 1 and 2
2 Water inlet 13 Timers’ time
3 Clock and timer settings 14 Mode selection
4 Compressor ON 15 Scroll down / Decrease
5 Conversion °C/°F 16 Water outlet
6 Dry contact OUT2 17 Scroll up / Increase
7 Fan ON 18 Save / settings
8 Not available 19 Defrost mode
9 Not available 20 Automatic mode
10 Locked screen 21 Heating mode
11 Alarm 22 Cooling mode

OFF Mode
When the heating pump is in sleep mode (OFF Mode) “OFF” is displayed on the command screen.

ON Mode
When the heating pump is running or regulating (ON Mode), the inlet and outlet water temperatures are displayed on the command screen.

At the end of a setting, press to validate.
The settings will be automatically saved if no button is pressed during 20s.

Clock settings
If the display is in standby mode, press briefly on .

  1. Press to bring up the symbol .
  2. Press to make the time display flash. Set the hour using the buttons
  3. Press then set the minutes with the buttons .
  4. Press to validate.

Timer function settings
Setting this function is necessary if you would like to run the heat pump for a shorter period than what is defined by the filtration clock. Therefore, you can program a deferred start and an anticipated stop or simply stop a certain timeframe from running (at night, for example).
It is possible to set 2 Start Timers (ON1 et ON2) and 2 Stop Timers (OFF1 et OFF2).

Timer 1 setting – Start

  1. Press for 2s, Timer ON1 1 flashes (*).
  2. Press to set the hours with the buttons .
  3. Press to set the minutes with the buttons .
  4. Press to validate.

Timer 1 setting – Stop

  1. Press for 2s, Timer ON1 1flashes (*).
    Press once, Timer OFF1 flashes.

  2. Press to set the hours with the buttons .

  3. Press to set the minutes with the buttons .

  4. Press to validate.

(*) To access Timer ON2 2directly, press for 2s, then press twice.

Timer 2 settings
After the Timer 1 settings, you will access directly the settings for Timer 2: 2 and 2.
Proceed in the same manner as for Timer 1.
Nota: To access directly Timer ON2 2, press for 2s, then press twice on .

Timers suppression (Start and Stop)

  1. Press for 2s, Timer ON1 1 flashes.(*)

  2. Press to make the time display flash.

  3. Press to suppress the Timer 1.

  4. Press to validate.

  5. Press for 2s, the Timer 1 flashes.
    Press once , the Timer 1 flashes.(*)

  6. Press to make the time display flash.

  7. Press to suppress the Timer 1.

(*) To access Timers 2 2 or 2. , follow steps 1) or 4) then press twice . Proceed in the same manner as above.

Operation mode selection: cooling, heating or automatic
In Mode “OFF” or “ON”
Press the button to change mode: cooling, heating or automatic.

If the heat pump is set in heating only or cooling only, changing mode is not possible.

Setting and visualisation of the set point (desired water temperature)
If the button is not visible on the screen, press briefly. (While operating or stopped, simply press the button to view the set point)

In Mode “OFF” or Mode “ON”
Press the button to display the set point, then press or to set the set point you wish.
The setting is made with a precision of 0.5 °C.

It is recommended to never exceed 30°C to avoid alteration of the liners.
Press the button for 5 s until it beeps and this symbol appears .
To unlock, press for 5 s until it beeps and this symbol disappears .

6.3  Exploded View- HP55TR

6.3 Spare Parts List -HP55TR

No9 Code Part name Part number
1 95005-310261 LED controller HPX95005-310261
2 32012-210488 Fan protection grille HPX32012-210488
3 20000-230340 Brand HPX20000-230340
4 32012-220074 Front panel HPX32012-220074
5 20000-330124 Motor HPX20000-330124
6 3500-2701 Fan blade HPX3500-2701
7 32012-210418 Motor support HPX32012-210418
8 32012-210079 Electrical box cover HPX32012-210079
9 32012-210414 Middle panel HPX32012-210414
10 32012-210415 Support panel HPX32012-210415
11 20000-360103 AC contactor HPX20000-360103
12 32012-210489 Top cover HPX32012-210489
13 2000-3526 Compressor capacitor HPX2000-3526
14 32012-120102 Evaporator HPX32012-120102
15 32012-210600 Left panel HPX32012-210600
16 20000-370003 Transformer HPX20000-370003
17 2000-3501 Fan motor capacitor HPX2000-3501
18 2000-3242 Coil temp. sensor HPX2000-3242
19 95005-310145 PCB board HPX95005-310145
20 20000-360005 Flow switch HPX20000-360005
21 2000-3242 Water inlet sensor HPX2000-3242
22 2000-3242 Water outlet sensor HPX2000-3242
23 32012-210078 Electrical box HPX32012-210078
24 32009-220032 Handle HPX32009-220032
25 32012-120142 PVC titanium condensor HPX32012-120142
26 32012-210601 Right panel HPX32012-210601
27 2001-3907 Terminalblock5connection HPX2001-3907
28 2000-3909 Terminalblock2connections HPX2000-3909
29 20000-360157 Pressure switch (0.3MPa/0.15MPa) HPX20000-360157
30 2001-3605 Pressure switch(3.2MPa/4.4MPa) HPX2001-3605
31 20000-140451 Electronic expansion valve HPX20000-140451
32 20000-140153 Needle valve HPX20000-140153
33 3400-2203 Drain connector HPX3400-2203
34 2004-1437 4wayvalve HPX2004-1437
35 20000-140153 Needle valve HPX20000-140153
36 20000-110267 Compressor HPX20000-110267
37 32012-210599 Chassis HPX32012-210599
38 2000-3242 Ambient temp. Sensor HPX2000-3242
39 32018-210143 Embedded network HPX32018-210143

6.3 Exploded view – HP75TR

6.3 Spare parts list HP75TR

No. Part code Part name Part number
1 95005-310261 Glass controller HPX95005-310261
2 32009-220076 Front Plate HPX32009-220076
3 32018-210143 Fan protection net HPX32018-210143
4 20000-270004 Axial fan HPX20000-270004
5 32009-210386 Front panel HPX32009-210386
6 20000-330134 Fan motor HPX20000-330134
7 32009-210500 Supporting transom HPX32009-210500
8 32018-210113-04 Fan motor holder HPX32018-210113-04
9 32009-210499 Electrical box cover HPX32009-210499
10 32009-210463 Fan bracket HPX32009-210463
11 32009-210391 Left panel HPX32009-210391
12 2000-3909 Terminal-2 HPX2000-3909
13 2000-3509 Fan capacitor HPX2000-3509
14 2000-3524 Compressor capacitor HPX2000-3524
15 20000-370003 Transformer HPX20000-370003
16 20000-360222 Compressor contactor HPX20000-360222
17 2001-3906 Terminal-3 HPX2001-3906
18 2001-3909 Terminal-3 HPX2001-3909
19 32018-210127 Top panel HPX32018-210127
20 20000-360005 Water flow switch HPX20000-360005
21 20000-360157 Low pressure switch HPX20000-360157
22 2001-3605 High pressure switch HPX2001-3605
23 2001-1491 4-way reverse valve HPX2001-1491
24 32009-120062 Heat exchanger HPX32009-120062
25 32009-210498 Electric box HPX32009-210498
26 32009-220032 Wiring box HPX32009-220032
27 32009-210497 Right panel HPX32009-210497
28 32009-120073 Titanium pipe heat exchanger HPX32009-120073
29 3400-2203 Drain connection HPX3400-2203
30 32009-210460 Middle panel HPX32009-210460
31 20000-110142 Compressor HPX20000-110142
32 32009-210496 Chassis HPX32009-210496
33 3500-1401 Gas-Liquid separator HPX3500-1401
34 95005-310145 Pc1001 PCB controller HPX95005-310145
35 2000-3510 Compressor capacitor HPX2000-3510
36 20000-140237 Electronic expansion valve HPX20000-140237
37 20000-230340 Brand HPX20000-230340

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals