Minoston MP22ZD Outdoor Z-Wave Dimmer Smart Plug Instruction Manual
- June 9, 2024
- Minoston
Table of Contents
MP22ZD Outdoor Z-Wave Dimmer Smart Plug
Instruction Manual
Model – MP22ZD(ZW96SD)
Specifications
Power: 125 VAC 60Hz
Frequency: 908.42 MHz
400W Incandescent 150W
Dimmable CFL/LED
Rainproof
If you have any questions, please contact us at
Scan QR code or visit ask@minoston.com and www.minoston.com
Adding Device To Z-Wave Network for QR CODE
Z-Wave Network Configuration
Add Device To Z-Wave Network
- Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
- Once the controller is ready to add your device, press the Manual/ Program button on the smart plug 3 times quickly. The blue LED will blink quickly. Auto-add mode: LED will blink within 30 seconds after first plugged in. Now, you have completed control to turn your fixture ON/OFF according to groups, schedules and interactive automation programmed by your controller. If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices.
To Remove The Device:
- Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
- Once the controller is ready to remove your device, press the manual/program button on the smart plug 3 times quickly.
Factory Default:
Manual: Click the button twice quickly then hold for at least 10 seconds.
(Light flashes once when reset successfully.) Host reset: Remove it from hub
the device will be restore to factory default.
FCC warning:
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference,
- This device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
CAUTION – PLEASE READ!
This device is intended for installation in accordance with the National
Electric Code and local regulations in the United States, or the Canadian
Electrical Code and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation consult a qualified
electrician.
MEDICAL EQUIPMENT
Please DO NOT use this plug to control Medical or Life Support equipment. This
device should never be used to control the On/Off status of Medical and/or
Life Support equipment.
OTHER WARNINGS
Risk of Fire / Risk of Electrical Shock / Risk of Burns
IMPORTANT SAFETY INSTRUCTIONS
-
READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
-
Read and follow all instructions that are on the product or provided with the product.
-
do not use an extension cord.
-
Reference the National Electrical Code, NFPA 70, specifically for the installation of wiring and clearances from power and lighting conductors.
-
Installation work and electrical wiring must be done by qualified person(s) in accordance with allapplicable codes and standards, including fire-rated construction.
-
do not install or use within 10 feet of a pool
-
do not use in a bathroom
-
WARNING:
Risk of Electric Shock.
When used outdoors, install only to a covered Class A GFCI protected receptacle that is weatherproof with the power unit connected to the receptacle. If one is not provided, contact a qualified electrician for proper installation. Ensure that the power unit and cord do not interfere with completely closing the receptacle cover. -
WARNING:
Risk of Electric Shock. Mount the unit at a height greater than 1 foot from the ground surface -
WARNING:
Risk of Electric fire. install only to a receptacle protected by 20A branch circuit over current protection.
SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>