DATALOGIC MATRIX 220 2D Imager Barcode Reader User Guide
- June 9, 2024
- DATALOGIC
Table of Contents
Matrix 220™
QUICK REFERENCE GUIDE
MATRIX 220 2D Imager Barcode Reader
http://www.datalogic.com/upload/res/manuals/ia/matrix_220_product_reference_guide_eng.pdf
SUPPORT THROUGH THE WEBSITE
Datalogic provides several services as well as technical support throughits
website. Log on to www.datalogic.com.
For quick access, from the home page click on the search icon , and type in
the name of the product you’re looking for. This allows you access todownload
Data Sheets, Manuals, Software & Utilities, and Drawings.
Hover over the Support & Service menu for access to Services andTechnical
Support.
INSTALLATION PROCEDURE
- Physically mount the Matrix 220 reader.
- Make the necessary electrical connections.
- Configure the reader using the X-PRESS interface (AIM, SETUP, LEARN and TEST for simple configuration) or the DL.CODE software configuration program (complete configuration).
Matrix 220™
1. Reading Window (ESD model shown)
2. Bracket Mounting Holes (2)
3. Power On LED
4. Ethernet Connection LED
5. 90° Rotating Connector Block| 5. HMI X-PRESS™ Interface
6. Ethernet Connector
7. Power – COM – I/O Connector
8. Power Over Ethernet Connector
9. COM, Trigger Connector
---|---
11. Lens
12. LED Aiming System
13. Red Spot (No Read)
14. Green Spot (Good Read)| 15. Non Polarized Illuminators
16. Polarized Illuminators
17. Diffused Illuminators
18. Standard Illuminators (Top/Bottom)
---|---
HMI X-PRESS™ INTERFACE
In normal operating mode the colors and meaning of the five LEDs are illustrated in the following table:
READY (green) | indicates the device is ready to operate. |
---|---|
GOOD (green) | confirms successful reading. |
TRIGGER (yellow) | indicates the status of the reading phase. |
COM (yellow) | indicates active communication on main serial port. |
STATUS (red) | indicates a NO READ result. |
During the reader startup (reset or restart phase), all the LEDs blink for one
second.
The single push button gives immediate access to the following relevant
functions:
| Test Mode with bar graph visualization to check static reading performance.
---|---
| Aim turns on the LED pointers to aim the reader at the target.
The target should be centered horizontally and vertically with respect to
the aiming squares.
| Setup to self-optimize and auto-configure photometry parameters.
| Learn to self-detect and auto-configure for reading an unknown barcode (by
type and length). Only one symbology type can be saved using this method.
Performing Autolearn on a second symbology will overwrite the first one.
M12 17-pin Power, COM, and I/O Connector Pinout
Pin| Name| Function
1| Vdc| Power supply input voltage +
2| GND| Power supply input voltage –
Connector Case| CHASSIS| Connector case provides electrical connection to the
chassis
6| I1A| External Trigger A (polarity insensitive)
5| I1B| External Trigger B (polarity insensitive)
13| I2A| Input 2 A (polarity insensitive)
3| I2B| Input 2 B (polarity insensitive)
9| O1| Output 1| (NPN or PNP short circuit protected and software
programmable)
8| O2| Output 2
16| O3| Output 3
14| RX| Auxiliary RS232 RX|
4| TX| Auxiliary RS232 TX|
7| ID+| ID-NET™ network +|
15| ID-| ID-NET™ network –|
Pin| Name| RS232| RS422 Full-Duplex
17
11
12
10| Main Serial
Port
(sw
selectable)| TX
RX
–
–| TX+
RX+
TX-
RX-
- do not leave floating. See Reference Manual for connection details.
M12 5-pin COM, Trigger Connector Pinout (PoE models)
Pin| Name| Function
1| I1A| External Trigger A (polarity insensitive)
2| RX| RS232 Main Serial Receive data signal
3| TX| RS232 Main Serial Transmit data signal
4| I1B| External Trigger B (polarity insensitive)
5| GND| RS232 Main Serial Reference signal
PoE models do not supply power to External Trigger.
M12 8-Pin Standard Ethernet Network Connector pinout
Pin| Name| Function
1| TX+| Transmit data (positive pin)
2| TX-| Transmit data (negative pin)
3| RX+| Receive data (positive pin)
4| RX-| Receive data (negative pin)
5| nc| Not Connected
6| nc| Not Connected
7| nc| Not Connected
8| nc| Not Connected
M12 8-Pin Power Over Ethernet Network Connector pinout
Pin| Name| Function
1| TX+| Transmit data (positive pin)
2| TX-| Transmit data (negative pin)
3| RX+| Receive data (positive pin)
4| RX-| Receive data (negative pin)
5| DC1-| DC Power (negative pin)
6| DC2-| DC Power (negative pin)
7| DC1+| DC Power (positive pin)
8| DC2+| DC Power (positive pin)
TECHNICAL FEATURES
ELECTRICAL FEATURES| |
---|---|---
Power| Standard Models| PoE Models
Supply Voltage (Vdc)| 10 to 30 Vdc| 48 Vdc
Consumption (A) Max.| 0.40 – 0.14 A (4.2 W)| 0.10 A (4.8 W)
Communication Interfaces
Main – RS232, RS422 full-duplex| 2400 to 115200 bit/s
Auxiliary – RS232| 2400 to 115200 bit/s
ID-NET™| Up to 1Mbaud
Ethernet 1| 10/100 Mbit/s
Inputs:| Opto-coupled and polarity insensitive (see Product Reference
Guide for details)
Max. Voltage| 30 Vdc
Max. Input Current| 10 mA
Outputs:| NPN or PNP short circuit protected (see Product Reference
Guide for details)
VOUT (ILOAD = 0 mA) Max.| 30 Vdc
VOUT (ILOAD = 100 mA) Max.| 3 Vdc
ILOAD Max.| 100 mA
OPTICAL FEATURES (see Product Reference Guide for details)
PHYSICAL FEATURES
Dimensions| H x W x L
Std Matrix 220 connector at 0°| 78 x 47 x 38 mm (3.1 x 1.9 x 1.5 in)
Std Matrix 220 connector at 90°| 58 x 47 x 58 mm (2.3 x 1.9 x 2.3 in)
ESD Matrix 220 connector at 0°| 78 x 47 x 43 mm (3.1 x 1.9 x 1.7 in)
ESD Matrix 220 connector at 90°| 58 x 47 x 63 mm (2.3 x 1.9 x 2.5 in)
Weight| 173 g. (6.1 oz.)
Material| Aluminium with plastic protective window cover
ENVIRONMENTAL FEATURES
Operating Temperature 2| -10 to 50 °C (14 to 122 °F) 3
Storage Temperature| -20 to 70 °C (-4 to 158 °F)
Max. Humidity| 90% non-condensing
Vibration Resistance EN 60068-2-6| 14 mm @ 2 to 10 Hz; 1.5 mm @ 13 to 55 Hz; 2
g @ 70 to 500 Hz; 2 hours on each axis
Shock Resistance EN 60068-2-27| 30g; 11 ms; 3 shocks on each axis
Protection Class4 EN 60529| IP65 and IP67
USER INTERFACE
LED Indicators| Power; Ready, Good, Trigger, Com, Status; Ethernet Network;
Green Spot; (see Product Reference Guide for other LEDs)
Other| X-PRESS™ Keypad Button (configurable via DL.CODE™)
SOFTWARE FEATURES
Readable Code Symbologies
1-D and stacked| 2-D| POSTAL| Digimarc Barcode
• PDF417 Standard and Micro PDF417
• Code 128 (GS1-128)
• Code 39 (Standard and Full ASCII)
• Code 32
• MSI
• Standard 2 of 5
• Matrix 2 of 5
• Interleaved 2 of 5| • Codabar
• Code 93
• Pharmacode
• EAN-8/13 – UPC-A/E (including Addon 2 and Addon 5)
• GS1 DataBar Family
• Composite Symbologies| • Data Matrix ECC 200 (Standard, GS1 and Direct
Marking)
• QR Code (Standard and Direct Marking)
• Micro QR Code
• MAXICODE
• Aztec Code| • Australia Post
• Royal Mail 4 State Customer
• Kix Code
• Japan Post
• PLANET
• POSTNET
• POSTNET (+BB)
• Intelligent Mail
• Swedish Post| • DWCODE™5
Operating Mode| CONTINUOUS, ONE SHOT, PHASE MODE
Configuration Methods| X-PRESS™ Human Machine Interface Windows-based SW
(DL.CODE™) via Ethernet
Host Mode Programming sequences sent over Serial or Ethernet TCP interfaces
Parameter Storage| Permanent memory (Flash)
- The embedded Ethernet interface supports application protocols: TCP/IP, EtherNet/IP, Profinet IO, Modbus TCP, OPC UA.
- High ambient temperature applications should use metal mounting bracket for heat dissipation.
- Operating temperature is 0 to 50 °C (32 to 122 °F) for the following models: 937900034, 937900035, 937900036, 937900037, 937900038, 937900039, 937900040, 937900041, 937900042.
- When correctly connected (fully tightened) to IP67 cables with seals.
- DWCODE models available.
PATENTS
See www.patents.datalogic.com for patent
list.
Matrix 220 is covered by one or more of the following patents:
Design patents: EP004735694
Utility patents: EP0996284B1, EP0999514B1, EP1014292B1, EP1128315B1,
EP1396811B1, EP1413971B1, EP2517148B1, EP2649555B1, JP4435343B2, JP4571258B2,
US6512218, US6616039, US6808114, US6997385, US7053954, US7387246, US7433590,
US8058600, US8368000, US8888003, US8915443, US9268982, US9430689, US9798948,
ZL200980163411.X
COMPLIANCE
Only connect Ethernet and dataport connections to a network which has routing only within the plant or building and no routing outside the plant or building.
EMC COMPLIANCE
In order to meet the EMC requirements:
- connect reader chassis to the plant earth ground by means of a flat copper braid shorter than 100 mm;
- connect pin “Earth” of the CBX connection box to a good Earth Ground;
CE COMPLIANCE
CE marking states the compliance of the product with essential requirements
listed in the applicable European directive. Since the directives and
applicable standards are subject to continuous updates, and since Datalogic
promptly adopts these updates, therefore the EU declaration of conformity is a
living document. The EU declaration of conformity is available for competent
authorities and customers through Datalogic commercial reference contacts.
Since April 20 th, 2016 the main European directives applicable to Datalogic
products require inclusion of an adequate analysis and assessment of the
risk(s). This evaluation was carried out in relation to the applicable points
of the standards listed in the Declaration of Conformity. Datalogic products
are mainly designed for integration purposes into more complex systems. For
this reason, it is under the responsibility of the system integrator to do a
new risk assessment regarding the final installation.
Warning
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate
measures.
FCC COMPLIANCE
Modifications or changes to this equipment without the expressed written
approval of Datalogic could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference which may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class
A digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
EAC COMPLIANCE
Customs Union:
The CU Conformity certification has been achieved; this allows the Product to
bear the Eurasian mark of conformity.
LED SAFETY
According to IEC 62471:2006 all models are exempt (Risk Group 0).
According to EN 62471:2008, using limits stated in the directive 2006/25/EC,
all models are exempt (Risk Group 0), except model Matrix 220 3U2-01U which is
Risk Group 3.
Note: for Matrix 220 3U2-01U, the measure of the NEAR UV radiation power
complies with the Risk Group 0 limit stated by the directive 2006/25/EC only
at a distance of 370 mm and farther, instead of the standardized distance of
200 mm.
POWER SUPPLY
This product is intended to be installed by Qualified Personnel only.
This product is intended to be connected to a UL Listed Direct Plug-in Power
Unit marked LPS or “Class 2”.
LEGAL NOTICES
© 2018-2022 Datalogic S.p.A. and/or its affiliates ALL RIGHTS RESERVED.
Without limiting the rights under copyright, no part of this documentation may
be reproduced, stored in or introduced into a retrieval system, or transmitted
in any orm or by any means, or for any purpose, without the express written
permission of Datalogic S.p.A. and/or its affiliates.
Datalogic and the Datalogic logo are registered trademarks of Datalogic S.p.A.
in many countries, including the U.S. and the E.U.
Matrix 220, ID-NET, DL.CODE, and X-PRESS are trademarks of Datalogic S.p.A.
and/or its affiliates. Digimarc® and DWCODE™ are trademarks of Digimarc
Corporation. All other trademarks and brands are property of their respective
owners.
Datalogic shall not be liable for technical or editorial errors or omissions
contained herein, nor for incidental or consequential damages resulting from
the use of this material.
821005635 (Rev. F)
References
- Datalogic | Automatic Data Capture and Industrial Automation - Datalogic
- Datalogic | Automatic Data Capture and Industrial Automation - Datalogic
- Patents - Datalogic
- Patents - Datalogic
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>