SAFETY WARNINGS AND REGULATIONS

Warnings
SAFETY SYMBOLSWARNINGS

  • Read this manual carefully before installing the appliance.

  • The appliance is an integral part of the system.
    Refer also to the documentation of the controlled boiler.

  • Installation may only be carried out by Professionally Qualified Personnel.

  • To ensure a correct reading of the average room temperature, do not place the Remote Control in direct sunlight or in the path of continuous draughts.

  • The manufacturer is not responsible for any damage to people, animals or objects resulting from incorrect or improper installation or use of the Remote Control.

ESD
The electronics are at risk of damage following electrostatic discharge (ESD); AVOID contact.

Restrictions

SAFETY SYMBOLSIT IS FORBIDDEN

  • Install the Remote Control near appliances which emit electromagnetic radiation.
  • The Remote Control is not to be used by children or unassisted disabled persons.

INSTALLATION

Receiving the product
The SIME SMART PLUS Remote Control is supplied in a single package, protected by cardboard.
INSTALLATION

In addition to the SIME SMART PLUS Remote Control, the following are also supplied:

  • Use and installation manual
  • 230 VAC – 24 VDC power supply
  • Expansion plugs
  • Small disposable screwdriver for SIME SMART PLUS terminals
  • Heat-shrink tubing for protecting cables near the terminals

SAFETY SYMBOLSIT IS FORBIDDEN
Do not leave packaging material around or near children since it could be dangerous. Dispose of it as prescribed by legislation in force.

Dimensions and weight
INSTALLATION

Description Remote Control Power supply
W (mm) 132 41
H (mm) 95 44
D (mm) 27 23
Weight (g) 170 35

Wiring diagram
INSTALLATION

KEY

  • VZ Relay contact for the valve/zone circulator pump (if present)
  • CR SIME boiler remote control unit connection (it is not possible to connect multiple SIME SMART PLUS devices to the same boiler) (cable: 2X0.75 mm2 non-polarised; maximum length: 50 m)
  • PS 230 VAC-24 VDC power supply (standard-supplied)
  • A (cable: 2×0.5 mm2 non-polarised; maximum length: 10 m)

NOTE: use the heat-shrink tubing supplied to protect the cables and guarantee isolation between them.

Wall mounting

The SIME SMART PLUS remote control unit can be installed on any wall, however the most suitable point should be chosen:

  • avoid air draughts (A);
  • do not install it above heat sources (B);
  • avoid direct sunlight (C);
  • position it at the proper height (D).
    INSTALLATION

The SIME SMART PLUS remote control unit can be installed exclusively in combination with SIME boilers (check the compatible models on the price list).

After having taken the SIME SMART PLUS Remote Control out of its packaging:

  • Use a screwdriver to push the fastening tab (1) to release the base (2) from the user interface (3) making sure that the screwdriver does not penetrate.
    INSTALLATION

  • Separate the 2 parts
    INSTALLATION

  • Secure the base plate (2) to the wall using the screws (4) and wall plugs (5) provided with the remote control unit.
    INSTALLATION
    NOTE: the power supply can be fitted in the rear junction box (as shown in the figure) or in another remote position up to a maximum connection length of 10 metres between the power supply and the SIME SMART PLUS device.

SAFETY SYMBOLSWARNING
The electrical connections must conform to the wiring diagram provided by the manufacturer of the boiler and must be made by the installer.

  • Connect to the terminal block (6) cable (A) of the power supply (provided) and cable CR of the SIME boiler

  • Connect the zone valve/circulator pump VZ (if present) to the relay contact (7)
    INSTALLATION

  • Refit the User interface (3) on the base (2) hooking the tab (1) correctly
    INSTALLATION

SAFETY SYMBOLSWARNING
Make sure that there is no excess cable between the base (2) and the user interface (3).

DESCRIPTION

Characteristics
The SIME SMART PLUS remote control unit is a functional and elegant system accessory that is user-friendly, thanks to its broad colour graphic display and 4 touch keys for navigating through the contents.
The connections to and communication with the boiler are made through a two- wire non-polarised bus line and OT protocol.
The main characteristics of the SIME SMART PLUS Remote Control are:

  • Wi-Fi connection to the domestic network for managing the system remotely through the Sime Connect app
  • Heating mode selection (Automatic/Manual/Off)
  • Domestic hot water mode selection (Automatic/Manual/Off)
  • Space heating and hot water temperature adjustment (Manual)
  • Weekly space heating and hot water scheduling (Automatic)with 4 daily time bands that can be differentiated for each day of the week.
  • Continuous adjustment of the boiler’s delivery temperature with room compensation (class V modulation – ErP) and the possibility of climatic influence if an external sensor is connected to the boiler (class VI adjustment – ErP)
  • Reading and setting of the boiler parameters
  • Anti-Legionella function scheduling
  • Continuous visualisation of the current date and time
  • Continuous visualisation of the room temperature
  • Visualisation of the boiler’s operating information
  • Recording of the boiler’s past alarms and visualisation/resetting of any current alarms
  • Dry contact relay for activating the zone pump or valve (if present)

NOTES:

  • In case of a power shortage, all the settings made will be stored except for the date and time, which will be memorised for about 24 hours.
  • Certain functions of the remote control may not be available in conjunction with certain specific generator models.

The Wi-Fi module has the following features:

  • it supports 802.11 b/g/n on a 2.4 GHz network.
  • encryption on supported networks: open, WEP, WPA, WPA2.

User interface
User interface

FUNCTION KEYS

  • CONFIRM key. To confirm a value or to access an active menu item.
  • BACK key. To cancel a selection or return to the previous page.
  • UP key. For increasing the temperature set-point / scrolling.
  • DOWN   key. For decreasing the temperature set-point / scrolling.

DISPLAY

  1. Heating schedule time bands
  2.  Description of adjustments under way
  3. Heating request under way
  4. Production of domestic hot water under way
  5. System pressure
  6. Time
  7. Date
  8. Status of Wi-Fi connection
  9. External sensor (if connected to the boiler)
  10. Measured room temperature
  11. Flame presence
  12. Flame percentage

USE

Start-up
Once installation of the SIME SMART PLUS Remote Control has been completed, proceed as follows:
USE

  • The display of the remote control unit will show the following “Main screen”.
    USE

Connecting SIME SMART PLUS to the WiFi network
(this step does not require the use of the Sime Connect app but only a smartphone)

  1. Make the electrical connections.

  2. Power up the SIME SMART PLUS.

  3. Choose a network name (SSID) and password of the Wi-Fi network to which the system must be connected SIME SMART PLUS.

  4. Check on your smartphone that there is a Wi-Fi signal in the exact point where the SIME SMART PLUS device.

  5. On the SIME SMART PLUS from the main page press the key; select “Wi-Fi” and “AP mode activation”. If the operation was carried out correctly, “AP” will appear at the top left-hand side of the display. If the operation was not completed correctly, repeat the procedure of point 5.

  6. On your smartphone search for the Wi-Fi network called “SIME SMART ##” and connect to it even if the device signals that there is no access to the Internet.

  7. Open a Web page from the device’s browser and enter the address 192.168.233.1 or, alternatively, scan the QR Code shown here. You will access a SIME page where you can set the credentials of the domestic Wi-Fi network to which the SIME SMART PLUS device will be connected.
    Press OK to confirm the settings.

  8. The connection phase may last up to 5 minutes. The icon will appear at the end if the connection was made correctly. If not, we suggest repeating the operations from point 5.

“SIME CONNECT” APP

To use the remote control functions of SIME SMART PLUS, install the “SIME CONNECT” app on your device, which is available for Android and iOS operating systems.


Subsequently, follow the instructions in the “SIME CONNECT” app to create a user profile and pair the SIME SMART PLUS device installed.

Rapid setting of the room temperature

The User, through the [ and ], buttons, can directly modify the “Room set- point” in WINTER mode from the “Main screen”.
Rapid setting of the room temperature

In MANUAL mode the set value will only be valid permanently while in the AUTO mode the set value will only be valid until the subsequent.
Rapid setting of the room temperature

MODO section navigation

MODO section navigation

To “select” lines or to “modify” values
To “confirm” selections or changes
To “move back” by one position

DHW time programme: allows for setting a weekly time schedule for preparing the domestic hot water in the storage tank (it has no effect on boilers with instantaneous preparation of the hot water). During the set periods, the boiler will heat the domestic hot water in the storage tank to the established set-point, while outside these periods the water will not be heated and only the anti-freeze protection will be guaranteed.
In setting the DHW time programme, the user must select a day of the week and use the following commands:

  • Add: to add a new water heating period (maximum 4 daily time bands).
  • Modify: to modify the set periods.
  • Delete: to eliminate a period.
  • Copy: to repeat the set programme in other days of the week.

Domestic hot water set-point: desired temperature for hot water to the taps and showers.

ZONE section navigation

ZONE section navigation

To “select” lines or to “modify” values
To “confirm” selections or changes
To “move back” by one position

Climatic: it is possible to set the climatic curve adjustment parameters for the dynamic calculation of the system delivery temperature in relation to the room temperature and the outdoor temperature (if the external probe is connected on the boiler).

ZONE section navigation

Set auto   comfort: desired room temperature in AUTO mode during the
comfort periods.

Curve slope: the boiler is configured for connecting to an external air temperature sensor and can operate with a sliding temperature. The boiler’s delivery temperature varies in relation to the external temperature depending on the selected climatic curve. (refer to the “CLIMATIC CURVE SLOPE” graph).

Room influence: the boiler’s delivery temperature can also be influenced by the temperature measured in the room depending on the set weight (0% = no influence).

K Amb: the boiler’s delivery temperature can also be influenced by the temperature measured in the room depending on the slope characterising the selected room component. (refer to the “ROOM COMPENSATION SLOPE” graph).

Offset Z1: It is possible to increase or reduce the boiler’s delivery temperature by a constant value compared to the automatic adjustment with a selected climatic curve and room component.

CLIMATIC CURVE SLOPE

Example with set temperature Room set-point = 20°C
CLIMATIC CURVE SLOPE

ROOM COMPENSATION SLOPE
Example with set temperature Room set-point = 20°C
ROOM COMPENSATION SLOPE

MENU section navigation

MENU section navigation

To “select” lines or to “modify” values
To “confirm” selections or changes
To “move back” by one position

Information: allows for viewing a few operating values relative to the type of system and the list of the last alarms/anomalies recorded.

MENU section navigation

Factory settings: allows for resetting the factory settings of the SIME SMART PLUS device.

Brightness in stand-by mode: after the set time, the display will decrease the brightness of the selected value (setting 100 will cause the display to switch off entirely).
Sensor calibration: the room temperature sensor can be calibrated to make it more accurate in relation to the installation site.

Technician: access to this menu is protected by an access code and is only allowed for qualified technical personnel. Unauthorised modification of the parameters can jeopardise the boiler’s operation.

Hot water: it is possible to enable and set the ANTI-LEGIONELLA FUNCTION which runs a disinfection cycle through a weekly thermal shock (the day and time can be set).
Enable it ONLY if a domestic hot water storage tank is present.

Wi-Fi section navigation
Wi-Fi section navigation

To “select” lines or to “modify” values
To “confirm” selections or changes
To “move back” by one position

AP   mode activation: starts the Access Point mode for connection to a Wi-Fi network – see Point 5 of paragraph “4.2 Connecting SIME SMART PLUS to the Wi-Fi network”.

Serial: allows for viewing the MAC address of the SIME SMART PLUS device installed (address shown also on the label).
Signal power: allows for viewing the signal power level of the Wi-Fi network in the installation point of the SIME SMART PLUS device.
Wi-Fi network name: allows for viewing the name of the WiFi network (SSID) to which the SIME SMART PLUS device is currently connected.

DISPOSAL

Appliance disposal (European Directive 2012/19/EU)

Boilers and electrical and electronic applianc-es from private households must not be dis-posed of as unsorted municipal waste at the end of their life. Instead, they must be taken to specific return and collection facilities, as per Directive 2012/19/EU and Italian Legisla-tive Decree 49/2014. For more information
on authorised collection facilities, please contact your local council or retailer. Individual coun-tries may also define specific rules on how to handle electrical and electronic waste.
Before disposing of your appliance, please check the rules in force in your country.

SAFETY SYMBOLSIT IS FORBIDDEN
dispose of the product together with municipal waste.

Customer Service

Fonderie Sime S.p.A – Via Garbo, 27 – 37045 Legnago (Vr)
Tel. +39 0442 631111
Fax +39 0442 631292
www.sime.it

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals