Simer HT7 Steel Pre-Charged Pressure Tank Owner’s Manual
- June 9, 2024
- Simer
Table of Contents
HT7 Steel Pre-Charged Pressure Tank
Owner’s Manual
Model Discontinued For Reference Only
Installation/Operation/Parts
For further operating, installation, or maintenance assistance:
Call 1-800-468-7867
Safety
READ AND FOLLOW SAFETY INSTRUCTIONS!
This is the safety alert symbol. When you see this symbol on your pump or
in this manual, look for one of the following signal words and be alert to the
potential for personal injury!
warns about hazards that will cause serious personal injury, death or major
property damage if ignored.
warns about hazards that can cause serious personal injury, death or major
property damage if ignored.
warns about hazards that will or can cause minor personal injury or property
damage if ignored.
The label NOTICE indicates special instructions which are important but
not related to hazards.
Carefully read and follow all safety instructions in this manual and on
pump.
Keep safety labels in good condition.
Replace missing or damaged safety labels.
- Read this manual carefully. Failure to follow these Instructions could cause serious bodily injury and/or property damage.
- Consult installer or licensed plumber for correct relief valve. Install system according to local codes.
- Always test water from well for purity before using. Check local health department for testing procedure.
- Before installing or servicing tank, BE SURE pump electric power source is disconnected. Release all water pressure before working on tank or system. Release air pressure before removing cover flange.
- Install a relief valve in pump supply line to tank, as close to tank as possible.
- BE SURE the pump electrical circuit is properly grounded.
- Remove bleeder orifices, air volume controls or other air charging devices in existing system.
- DO NOT USE tank as a surge suppressor.
Hazardous pressure. To prevent possible serious or fatal injury and/or damage
to equipment, system pressure must be less than 100 pounds per square inch
(PSI) (689kPa) under any circumstances. Failure to follow instruction can
result in tank blowup. If system discharge pressure can exceed 100 PSI
(689kPa), install a relief valve capable of passing the full pump volume at
100 PSI (689kPa).
Do not allow pump, tank, or piping system to freeze.
Freezing can severely damage equipment and may lead to tank explosion and
serious injury. Allowing tank to freeze voids tank warranty.
Simmer Limited Warranty
SIMER warrants to the original consumer purchaser (“Purchaser”) of its
products that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase
any such product shall prove to be defective, it shall be repaired or replaced
at SIMER’s option, subject to the terms and conditions set forth below. Your
original receipt of purchase is required to determine warranty eligibility.
Exceptions to the Twelve (12) Month Warranty
Five (5) Year Warranty:
If within five (5) years from original consumer purchase any Pre-Charge water
system tank shall prove to be defective, it shall be repaired or replaced at
SIMER’s option, subject to the terms and conditions set forth below.
General Terms and Conditions
Purchaser must pay all labor and shipping charges necessary to replace product
covered by this warranty. This warranty shall not apply to acts of God, nor
shall it apply to products which, in the sole judgement of SIMER, have been
subject to negligence, abuse, accident, misapplication, tampering, alteration;
nor due to improper installation, operation, maintenance or storage; nor to
other than normal application, use or service, including but not limited to,
operational failures caused by corrosion, rust or other foreign materials in
the system, or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the
defective product to the Retail outlet or to SIMER as soon as possible after
the discovery of any alleged defect. SIMER will subsequently take corrective
action as promptly as reasonably possible. No requests for service under this
warranty will be accepted if received more than 30 days after the term of the
warranty.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive
remedy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS
WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE APPLICABLE
EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or
consequential damages or limitations on how long an implied warranty lasts, so
the above limitations or exclusions may not apply to you. This warranty gives
you specific legal rights and you may also have other rights which vary from
state to state.
SIMER • 293 Wright St. • Delavan, WI U.S.A. 53115
Phone: 1-800-468-7867 /
1-800-546-7867 • Fax:
1-800-390-5351
Installation
The tanks listed below are pre-charged, or filled with air at the factory, as shown under “Product Information – Pre-Charged Tanks,” below. When installing tank or if drawdown decreases significantly, check as follows:
- To check air charge in tank, shut off electric power to pump, open faucet near tank, and drain completely.
- At air valve, unscrew air valve protective cap and check tank air pressure with tire gauge. See Chart 1 for the correct pressure setting. If needed, adjust the tank pressure up or down. To do this, bleed air from or add air to tank through valve on top of tank.
- Use soap or liquid detergent to check for air leaks around air valve. Continuous bubbling indicates leak.
If necessary, release air pressure and install new core in air valve (same as used for automobile tubeless tires.)
NOTICE: Always set or check tank pre-charge with NO WATER in tank and no
water pressure in system. If you have already pumped water before setting or
checking the pre-charge pressure, turn the pump off.
NOTICE: Replace and tighten air valve protective cap after pressure is
adjusted correctly. Failure to replace cap may allow loss of air pressure and
lead to tank waterlogging and diaphragm failure.
Chart I
When Pressure Switch Setting Is| Adjust Tank RECHARGE
(PSI) To
---|---
20-40 PSI (138-276kPa)
30-50 PSI (207-345kPa)| 18 (124kPa)
28 (193kPa)
(The first number on the pressure switch is the pump “ON” setting; the second
number is the pump “OFF” setting.)
This tank is designed to be supported by the system piping either directly
above the pump or in a convenient location in the piping system as close to
the pump as possible.
NOTICE: Tank capacity is different than drawdown. Tank capacity is the
actual physical volume of the sheet metal that makes up the tank.
STANDARD TANK REPLACEMENT
When replacing a standard tank in a water system with a pre-charged tank, no
bleeder orifices or Air Volume Control (AVC) are required. When sizing a pre-
charged tank to replace a standard tank, the tanks should have equivalent
drawdowns.
WARNING Hazardous voltage and hazardous pressure. Disconnect all power
to pump and bleed all pressure from system before working on pump, tank, or
piping.
Figure 1: Air valve and protective cap.
Product Information – Pre-Charged Tanks
Catalog
Number| Maximum
Capacity
US Gals (L)| Equivalent to Standard
Tank
(US Gals) (L)| Drawdown – Gals (L)| Tank
Diameter
in. (mm)| Tank
Height
in. (mm)| Tank
Discharge
Tapping| Pre-Charge
Pressure
PSI (kPa)
---|---|---|---|---|---|---|---
20-40 PSI
(138-276kPa)| 30-50 PSI
(207-345kPa)
LT2| 2 (7.6)| 6 (23)| 0.7 (2.7)| 0.6 (2.3)| 8.4″ (213)|
12.6″ (319)| 3/4″| 20 (138)
LT5| 5 (19)| 15 (58)| 1.8 (6.8)| 1.5 (5.7)| 10.6″ (270)|
16.2″ (411)| 3/4″| 30 (207)
HT7| 7 (26)| 21 (78)| 2.2 (8.3)| 1.9 (7.2)| 10.6″ (270)|
18.5″ (470)| 3/4″| 30 (207)
VT14| 14 (53)| 42 (160)| 4.9 (18.5)| 4.2 (15.9)| 15.8″
(401)| 23.3″ (591)| 1″| 30 (207)
For assistance, call Simmer Customer Service at
1-800-468-7867 /
1-800-546-7867 293 Wright St.,
Delavan, WI 53115
Phone: 1-800-468-7867
1-800-546-7867
Fax: 1-800-390-5351
Web Site: http://www.simerpump.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>