General Information

These instructions should be read carefully and retained for further reference and maintenance.

Safety

  • Before installation or maintenance, ensure the mains supply to the luminaire
    is switched off and the circuit supply fuses are removed or the circuit breaker turned off.

  • It is recommended that a qualified electrician is consulted or used for the installation of this luminaire and install in accordance with the current IEE wiring and Building Regulations.

  • Check that the total load on the circuit including when this luminaire is fitted does not exceed the rating of the circuit cable, fuse or circuit breaker.

Technical Specifications

  • 230V AC 50 Hz
  • This luminaire is of class I construction and must be earthed
  • LED non replaceable lamp
  • Colour Temperature: 5000K
  • IP65 Rated suitable for restricted external applications
  • UKCA & CE Approved
Mode Watts Lumen Mounting Output Hole Centres Dimensions
LEDBHR7W 7W 700lm 88mm Ø153 D:59
LEDBHR15W 15W 1000lm 126mm Ø185 D:65
LEDBHR25W 25W 2000lm 155mm Ø244 D:75
LEDBHO9WN 7W 700lm 124mm H:155 W:100 D:52
LEDBHO15W 15W 1000lm 176mm H:215 W:131 D:69
LEDBHO25W 25W 2000lm 220lm H:270 W:165 D:86

Installation

  • Remove the front of the unit by undoing the 4 bolts remove the bezel and lens with gasket.
  • Mark the position of the mounting holes on the wall using the unit as a template.
  • Drill the holes for the wall plugs ensuring not to infringe with any gas/water pipes or electrical cables that may be hidden below the surface.
  • Undo the cable gland sufficiently to allow the cable to be pushed through the back.
  • Secure the supply cable into the luminaire through the hole(s) provided ensuring that a cable gland, grommet or sealing compound is used to maintain the IP rating of the luminaire.
  • Leave enough slack to allow for wiring, re-tighten the cable gland.
  • Fix the luminaire using the correct screws for the wall plugs installed.
  • Terminate the cable into the terminal block (see section 5 connection diagram) ensuring correct polarity is observed and that all bare conductors are sleeved.
  • Secure the supply cable using the cable clamp.
  • Reposition the lens over the unit, taking care to ensure the gasket is in place.
  • Secure the lens and bezel back into place using the 4 bolts previously removed at the beginning of the installation.
    Product Overview

Connection

Connecting Instruction

Live (Brown or Red):   L
Neutral (Blue or Black): N
Earth (Green/Yellow):

Operation

Turn the power and the unit will illuminate.

3 Year Guarantee

In the unlikely event of this product becoming faulty due to defective material or
manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year, telephone the helpline on 020 8450 0515.

Note:
A proof of purchase is required in all cases. For all eligible replacements (where agreed by Timeguard) the customer is responsible for all shipping/postage charges outside of the UK.All shipping costs are to be paid in advance before a replacement is sent.

If you experience problems, do not immediately return the unit to the store. Telephone the Timeguard Customer Helpline;

HELPLINE

020 8450 0515
or email helpline@timeguard.com
Qualified Customer Support Coordinators will be on-line to assist in resolving your query.

TIMEGUARD

A Theben  group Company
For a product brochure please contact:

Time guard Limited.

Victory Park, 400 Edgware Road,
London NW2 6ND
Sales Office: 020 8452 1112
or email csc@timeguard.com
www.timeguard.com

Logo TIMEGUARD LEDBHR7W LED Energy Saver Bulkhead
Light

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

TIMEGUARD User Manuals

Related Manuals