Tap Operation

Classic tap
Chilled Water
Depressing the left lever allows the dispensing of chilled water as long as the lever is held down (max. 15 sec.). Pulling forward the blue lever allows the tap to operate in a “no-touch” mode. Water will flow from between 5 and 15 seconds (this is user adjustable). To reset, return the handle to the off position and repeat the step. The lever has to be manually returned to the off position.
Tap Operation

Sparkling Water
Depressing the right Chilled Sparkling water Lever allows the dispensing of chilled and sparkled water with carbon dioxide added.
Pull the lever up to dispense sparkling water continually. The water will fl ow for 5 to 15 seconds (this is user adjustable). To reset, return the handle to the off position and repeat the step. The lever has to be manually returned to the off position.

Classic Plus tap
Chilled Water
Press the blue button to tap chilled water. When the button is pressed, chilled water flows as long as it is held down (max. 15 sec.).

Sparkling Water
Press the white button to dispense sparkling water with carbon dioxide added. When the button is pressed, sparkling water flows as long as it is held down (max. 15 sec.).

Quantity Filling
Before selecting the water type, press the fi ll button. After pressing the blue or white button briefly, water flows for a period of between 5 and 15 seconds, which can be set in the menu.
Tap Operation

Touch-Free Tap
Chilled Water
Hold your hand approx. 1.5 – 5 cm in front of the right sensor to dispense chilled water. Chilled water flows as long as the hand is held in the sensor area (max. 15 sec.). If the rear sensor is also triggered, water flows for a period of between 5 and 15 seconds that can be set in the menu.
Tap Operation

Sparkling Water
Hold your hand approx. 1.5 – 5 cm above the tap to dispense carbonated sparkling water. Sparkling water flows as long as the hand is held in the sensor area (max. 15 sec.). If the rear sensor is also triggered, water flows for a period of between 5 and 15 seconds that can be set in the menu.
Tap Operation

Arc tap
Select the desired type of water by tipping to on the Select button on the Zip lever at the tap.
Tap Operation

  • Blue: chilled water
  • White: sparkling water

Turn the lever to dispense water. When the lever is turned back, water will flow as long as the lever is held. If the lever is turned forwards, water will flow continually for 5 to 15 seconds. This time can be set in the menu.
The lever then has to be manually returned to the Off position.

Tap LEDs (Touch-Free excluded)

Blue Chilled Water LED

On all the time
This indicates that the chilled water is ready.

Flashing slowly
This indicates that the temperature of chilled water is not within the set range.
When the chilled water is at the set temperature, the light will stop flashing. This could take several minutes.
During heavy usage, the temperature can rise out of this range.

White Filter LED (Classic only)

White filter LED off
This indicates the filter is operating within its normal specified lifespan.

White filter LED flashing slowly
The light will flash slowly when the filter is due for replacement and the LCD will show “Filter Change”. Refer to chapter “Replacing the filter”.
Tap Operation

Note: For the taps Arc the need for a filter replacement is indicated by cyclically flashing all the LEDs in all colours.

LCD Screen

The Zip HydroTap has a touch screen for easy operation and setting.
By tapping on the various icons, different views can be called up or the unit can be switched to standby. Tapping on the three bars at the top left opens the main menu.

Chilled water temperature
The set chilled water temperature is displayed.
LCD Screen

CO2 status
The filling level of the CO2 cylinder is determined on the basis of the previous consumption and displayed as a percentage. As soon as a residual capacity of 20% is reached, a warning appears, prompting you to have a replacement cylinder ready.
LCD Screen
LCD Screen

Filter status
When the maximum filter life is reached, a warning indicator appears.
LCD Screen

Energy saving
The settings for saving energy are displayed here. By tapping on the arrows, the associated settings menus can be called up directly.
LCD Screen

LCD Screen Menu

Main menu

|

submenu

|

Submenu Options

|

Section

---|---|---|---
General Settings| >    Language

    Date & Time

    Network (n/a)

| >    German

    English

    French

    12/24 h Mode

| A
System Settings| >    Filter Settings

    Temperature

    CO2 Settings

    Dispense Time

    Light Sensor

    Quiet Mode

    Advanced Settings

    System reset

| >    Filter Flush

    Tank Flush

    Set Target Values

    CO2 Flush

    Set Dispensing Times

    Calibrate Sensor

    Set Fan Speed

| B
Safety & Security| >    Password Protect| >    Set Password

    Change Password

| C
Energy Saving| >    Sleep Mode

    ON/OFF Timer

    Energy Use

| >    Sleep When

    When Sleeping

    Operating Times

| D
Info & Logs| >    Filter Logs

    System Faults

    Recent Faults

    About System

| | E
Serial number| >    Serial number as a bar code| |
Register Product| >    n/a|  |
Service| >    Password protected| | H

LCD Screen Operation – Section A

A General Settings

During the initial start-up, the language must be selected and the time with the current date must be entered. In addition, both menus can be found under General Settings
LCD Screen Operation - Section A

I. Language

Tap the circle above your preferred language. You can choose between German, English and French
LCD Screen Operation - Section A

II. Date & Time

Touch the text boxes on the screen and then touch + and – to set the current date and time. Select the tick to confirm and save.
LCD Screen Operation - Section A

LCD Screen Operation – Section B

B System Settings

As soon as your Zip HydroTap G5 is connected for the first time, the configuration starts automatically. In addition, the unit can be configured manually in the system settings.
LCD Screen Operation - Section B

I. Filter Settings

The filter and water tanks must be rinsed during initial operation, after each filter change and after a longer period of non-use.
LCD Screen Operation - Section B

Filter Flush
Have a bucket or similar container at the ready to hold a quantity of water that will be ejected while the filter flush mode is in operation. Open the filter access door on the front of the HydroTap and the filter cartridge will be exposed. Located to the rear RHS of the cartridge is a flush line, approx 600 mm long and the flush line stop cock. Hold the free end of the flush line into the bucket or container.
LCD Screen Operation - Section B

Open the valve as shown in the picture above and start the rinsing process by tapping on the green arrow.
The flushing process takes about two minutes.

After the rinsing process is completed, a message appears. Close the valve, guide the flushing line back into the filter compartment and close the filter flap. Next, reset the filter counter.
LCD Screen Operation - Section B

Filter Reset
Select the internal/external filter consumption and reset it by keystroke after each filter change.
LCD Screen Operation - Section B

Internal Filter Life
Enter the lifetime of the filter and the current consumption (new filter: 000).
If the consumption exceeds the service life of the filter, flashing
LCD Screen Operation - Section B

II. Temperature Settings

This is where the water temperatures are set for operation.
LCD Screen Operation - Section B

Chilled water / Sparkling water
To ensure the best possible CO2 binding to the water for sparkling water, the temperature is fixed at optimal values and cannot be changed.
LCD Screen Operation - Section B

III. CO2 Settings

Every time the unit is put into operation and after changing the CO2 cylinder, the carbonator must be purged with CO2 and the counter reset.
LCD Screen Operation - Section B

CO2 Purge
To start the function, tap the green arrow. The flush runs for approx. 30 seconds and ends automatically.
LCD Screen Operation - Section B

CO2 Reset
The consumption counter is reset by selecting the circle and then tapping the round arrow.
LCD Screen Operation - Section B

CO2 Life
The CO2 capacity can be set in months or litres. A warning is shown on the display as soon as the CO2 content reaches 20 %.
LCD Screen Operation - Section B

One 1.2 kg cylinder of CO2 is enough for about 180 – 200 litres of sparkling water.

IV. Dispense Times

For all taps with a filling function and for each type of water, a duration of 5 – 15 seconds can be set here for automatic dispensing.
LCD Screen Operation - Section B

V. Light Sensor (Classic- & Classic Plus only)

Follow the instructions on the display. Before each calibration, make sure that the ambient light corresponds to the typical lighting conditions at the installation site.
LCD Screen Operation - Section B

Remove any reflective or shadowing objects from around the fixture.

VI. Quiet Mode

A lower fan speed can reduce noise.
Increasing the speed can improve the cooling performance.
Levels: 75% / 100% / Auto (default).
LCD Screen Operation - Section B

VII. System Restart

Tap first on the upper circle and then on the lower circle to switch off and restart the system. Use this function to reset errors or reset the password for the settings.
LCD Screen Operation - Section B

LCD Screen Operation – Section C

C Safety & Security

You have the option of activating protection against the unauthorised changes with a password.
LCD Screen Operation - Section C

I. Password

The Zip HydroTap allows the appliance coordinator to set up a password to protect against users changing the preferred system settings.
LCD Screen Operation - Section C

LCD Screen Operation – Section D

D Energy Saving

Different sleep modes can be selected, the operating times can be set and the previous energy consumption can be viewed.
LCD Screen Operation - Section D

Note: For the best possible water hygiene, it is recommended to leave the heating and cooling of the unit permanently active.

I. Sleep Mode

When the function is active, the water temperature control is reduced or switched off completely.
Each tapping during the sleep mode activates the unit. However, a few minutes are needed to bring the water back to the setpoint.
LCD Screen Operation - Section D

Sleep when…
Choose: in it gets dark, not used in 2 hours or both.
LCD Screen Operation - Section D

The “darkness” option only works on taps with a light sensor (Classic, Classic Plus). It is recommended to calibrate the light sensor.

When Sleeping
Set the actions for your HydroTap during the sleep mode.
LCD Screen Operation - Section D

Switch   off   system: Water cooling and water heating are deactivated. The water temperature adjusts to the room temperature.
Note: The unit needs a few minutes to heat/cool the water to the setpoint again when the sleep mode is interrupted.

II. On/Off Mode

The On/Off Mode allows the user to turn the unit on or off at a specific time. One On/Off period is possible per day.
LCD Screen Operation - Section D

Note: Any attempt, during OFF mode, to dispense water, will bring the unit out of sleep mode. Please allow sufficient time for the water to reach the set temperature after disabling the sleep mode. The unit will return to sleep mode after 30 Minutes of non use.

Select one of the functions Everyday, Weekdays / Weekends or Individual days for your time switch. Then set the desired switch-off and switch-on times in the function. Tap the tick to confirm and save.
LCD Screen Operation - Section D

III. Energy Use

Track the energy consumption of your HydroTap by viewing the total energy consumption and the energy consumption since the last energy consumption reset.
LCD Screen Operation - Section D

LCD Screen Operation – Section E

E Info & Logs

Here you can view all filter changes, logged system errors and current error messages.
LCD Screen Operation - Section E

The system info gives you an overview of the serial number, model and other details of your system
LCD Screen Operation - Section E

LCD Screen Operation – Section H

H Service

Caution must be observed when changing any settings within the Service Menu as any changes may affect the normal operation of the unit. This can only be done by a technician. Please contact the Clage after sales service for further assistance.

Filter Maintenance

Water Filter
The Zip HydroTap notifies when filter replacement is due. If you notice one of the following, you will need to change the filter.

  • The Change Filter LED will flash white once a second and remain so until reset. The filter status light is located below the levers on the tap head assembly (Classic).
  • All LEDs of the tap flash approx. every 10 seconds in all three colours (Arc / Celsius Arc).
  • The filter percentage will show 0% on the Home screen.

Note: Replace the filter after a non-use of more than two months, even if the change interval has not yet been reached!
Note: Depending on local water quality conditions and usage, the filter may require changing anywhere from 500Ltrs to 10000Ltrs.
You may also need to replace the filter if you notice unpleasant odours or tastes.

Some water may drip from the filter head (socket) during replacement. Keep a towel handy to dry up any drips.

To change the Filter: (See also section B)

  1. Open the door of the under sink unit.
  2. Relieve system pressure via the filter flush stop cock, a quick open and close will do. Use the bucket to catch the discharge.
  3. Grasp filter cartridge and rotate the cartridge a quarter turn to the left, then gently pull down.
  4. Caution: a small amount of water will drip as the cartridge is removed.
  5. Do not tilt the cartridge as water may spill from it if tilted.
  6. Unpack replacement cartridge and remove sanitary cap, write today’s date where shown on the label.
  7. Avoid touching the filter O-rings and filter opening as this may cause bacterial contamination of the cartridge.
  8. Moisten the O-rings with water, align the front cartridge label to the left (as shown in the diagram for filter cartridge replacement), and push the new cartridge into the filter head.
  9. Turn the cartridge a quarter turn to the right until the cartridge comes to complete stop and is locked into position, with the front label facing forward.
  10. Initiate the filter flush programme by scrolling through the menu screen (See section B I).
  11. Close the door to secure the appliance.
  12. Adjust the filter settings as described in section B.
  13. Dispose of the used filter correctly
    To change the Filter
    Warning: If the Zip HydroTap is switched off for a long period of time (e.g. More than a weekend), run water through the chilled water outlet for at least 5 minutes before consumption.

Air Inlet Filter
The Zip HydroTap air filter is conveniently located on the outside of the condenser. The filter screen is a sliding fi t in the plastic housing on the side of the under sink unit. The screen may be removed for cleaning, by sliding it forward. This needs to be inspected at least quarterly, cleaned and replaced if damaged.

Note: For best performance the unit should only be operated with a clean air filter screen, correctly fitted in place. Maintain, at least, a 50 mm air gap in front of the screen at all times. Take care not to allow cloths or other soft materials to accidentally block the air inlet.
Air Inlet Filter

Cleaning

General cleaning
Do not use strong, corrosive, spray or abrasive cleaners. The plastic surfaces and taps should be wiped with a slightly wet and hygienic cloth only.
Under sink units must never be located near, or cleaned with water jets.
Avoid using air borne pesticides near the undersink unit.

We recommend cleaning the tap and the tap spout with CLAGE Desinfekt at regular intervals. Article number: 4100-44145

CO2 Bottle Replacement

If the carbon dioxide gas bottle is empty, replace it as follows:

  1. Close the red lever on the pressure reducer.

  2. Turn the pressure adjusting screw on the pressure reducer anticlockwise as far as it will go (no pressure).

  3. Replacing the carbon dioxide gas bottles:
    Gas bottle with self closing valve:

    Unscrew the gas bottle from the pressure reducer.
    Quickly screw the new, full gas bottle into the pressure reducer, as far as it will go.
    Secure the new gas bottle in place on the holder so that it cannot topple over.
    Gas bottle with hand wheel:
    Close the shut-off valve on the gas bottle.
    Undo the union nut connecting the gas bottle to the pressure reducer.
    Remove the gas bottle and secure the new gas bottle in place on the holder so that it cannot topple over.
    Connect the pressure reducer to the new, full gas bottle. Tighten the union nut moderately tight.

  4. Set a delivery pressure of 3.0bar on the pressure reducer of the carbon dioxide gas bottle. Turn the adjusting screw anticlockwise to reduce the pressure. Turn it clockwise to increase the pressure.

  5. Open the red lever on the pressure reducer.

  6. Check the gas-carrying connections for leaks. Caution – gas released can be very cold. Use a leak detecting spray or soapy water so that even minor leaks will be detected.

Note: The room where a carbon dioxide gas bottle is placed must have a minimum room volume of 17 m3 for every kg of bottle capacity. This means in a room with an assumed room height of 2.2 m, you will need an area of 7,7 m2

Note: The carbon dioxide gas bottle must always be used in the upright position to ensure that the pressure reducer operates correctly and thus ensure the safety of the unit!

Note: The carbon dioxide gas bottle must not be exposed to temperatures higher than 35 °C! Cooling should be provided if necessary.