MOXA NPort W2150A-W4, NPort W2250A-W4 Series Wireless Device Servers Installation Guide

June 9, 2024
MOXA

MOXA NPort W2150A-W4, NPort W2250A-W4 Series Wireless Device Servers

Overview

The NPort W2150A-W4/W2250A-W4 wireless device servers are an ideal choice for connecting serial devices or Ethernet devices, including PLCs, meters, and sensors, to an IP-based wireless LAN or Ethernet LAN.

Features

  • Links serial and Ethernet devices to an IEEE 802.11a/b/g/n network
  • Web-based configuration using built-in Ethernet or WLAN
  • Secure boot for Moxa-only allowed firmware allowed to run
  • Remote configuration with HTTPS, SSH
  • Secure data access with WEP, WPA, WPA2
  • Fast roaming for quick automatic switching between access points
  • Offline port buffering and serial data log
  • Enhanced surge protection for serial, LAN, and power
  • Dual power inputs (1 screw-type power jack, 1 terminal block)

Package Checklist

Before installing the NPort W2150A/W2250A-W4 device server, verify that the package contains the following items:

  • 1 NPort W2150A-W4 or NPort W2250A-W4 wireless device server.
  • 1 antenna 2.4/5GHz: ANT-WDB-ASM-03 BK.
  • 100 to 240 VAC power adapter. (excluding T models)*
  • 1 Ethernet cable: CBL-RJ458P-100.
  • Quick installation guide (printed).
  • Warranty card.

NOTE The power adapter is suitable for your region.

Optional Accessories

  • DK35A (35 mm DIN-rail mounting kit; 4 screws included).
  • CBL-PJ21NOPEN-BK-30: Locking barrel plug to bare-wires cable.
  • Mini DB9F-to-TB: DB9-female-to-terminal-block adapter for RS-422/485 applications.

NOTE
Notify your sales representative if any of the above items are missing or damaged.

ATTENTION
To comply with FCC RF exposure compliance requirements, the antenna used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.

NOTE
Before connecting the NPort W2150A-W4 and NPort W2250A-W4 Series DC power inputs, make sure the DC power source voltage is stable.

  • A qualified person must install the wiring for the input terminal block.
  • Wire type : Cu.
  • Only use 12 to 28 AWG wire size and a torque value of 0.51 N-m.

NOTE
The operating temperature of the power adapter (included with the NPort W2150A-W4/W2250A-W4) is from 0 to 40°C (32 to 104°F). If your application is not in this range, please use a power adapter supplied according to the requirements below:

  • The external power source must comply with UL listed, IEC 60950-1, or IEC/EN 62368-1.
  • Output complies to SELV/ES1, PS2/LPS; output rating 12 to 48 VDC, 0.455 A minimum.
  • A minimum ambient temperature of 55°C or 75°C. (55°C for the NPort W2150A-W4 and NPort W2250A-W4; 75°C for the NPort W2150A-W4-T and NPort W2250A-W4-T)

Hardware Introduction
The NPort W2150A-W4 models have one serial port; the NPort W2250A-W4 models have two serial ports. Both models support RS-232/422/485 operation with DB9 connectors and include one 10/100M Ethernet port.

MOXA-NPort-W2150A-W4-NPort-W2250A-W4-Series-Wireless-Device-Servers-
fig-1

Reset Button: The reset button is used to load the factory default settings. Use a pointed object to hold the reset button down for five seconds to load the factory defaults.

Name Color Function

End Panel LED Indicators

Ethernet

| Orange| 10 Mbps Ethernet connection.
Green| 100 Mbps Ethernet connection.
Off| Ethernet cable is disconnected.
Top Panel LED Indicators

Ready

|

Red

| Steady on:| Power is on, and the NPort is booting

up.

Blinking:| An IP conflict exists or the DHCP server

did not respond properly.

Green

| Steady on:| The NPort is functioning normally.
Blinking:| The NPort is responding to Locate

function.

Off| Power is off or a power error condition exists.

WLAN

|

Green

| Steady on:| Wireless enabled.
Blinking:| The NPort can’t establish a WLAN

connection with the AP (Infrastructure).

Off| Wireless not enabled.
Serial 1

Serial 2

| Orange| The serial port is receiving data.
Green| The serial port is transmitting data.
Off| No data is flowing to or from the serial port.
Name| Color| Function
---|---|---

Signal Strength

|

Red

| 1 Red –| The signal strength (RSSI) is lower than

-88 dBm.

2 Red –| The signal strength (RSSI) is between

-87 to -79 dBm.

Green

| 3 Green –| The signal strength (RSSI) is between

-78 to -68 dBm.

4 Green –| The signal strength (RSSI) is between

-67 to -60 dBm.

5 Green –| The signal strength (RSSI) is between

-59 to -45 dBm.

Pull-high/low Resistors and Termination Resistor for RS-422/485

You may need to set the pull-high/low resistors when the termination resistors are used in certain RS-422 or RS-485 environments.

S4 (Serial 1)

S5 (Serial 2)

| DIP 1| DIP 2| DIP 3| DIP 4
---|---|---|---|---
Pull-high Resistor| Pull-low Resistor| Termination Resistor| Reserved
ON| 1 kΩ| 1 kΩ| 120 Ω| –
OFF (Default)| 150 kΩ| 150 kΩ| N/A| –

S5 is for the NPort W2250A-W4 only.

NOTE
Do not use the 1 kΩ setting while in RS-232 mode. Doing so will degrade the RS-232 signals and reduce the effective communication distance.

First-Time Hardware Installation

  1. STEP 1 : After removing the NPort W2150A-W4/W2250A-W4 from the box, use a crossover Ethernet cable to connect the NPort’s RJ45 Ethernet port directly to your computer’s Ethernet port.
  2. STEP 2 : Attach the power adapter to the NPort and then plug the adapter into an electrical outlet.
  3. STEP 3 : Configure the NPort W2150A-W4/W2250A-W4 through the Ethernet port. See the next section on how to install software.

NOTE
You must connect the Ethernet cable first before powering up your NPort.

Wall Mounting (Optional)
Mounting the NPort W2x50A-W4 Series on the wall requires 2 screws. The heads of the screws should follow the specification of the M3 pitch 0.5 screws with a minimum length > 7mm.

NOTE
Do not screw the screws in all the way—leave about 2 mm to allow room for sliding the wall mount panel between the wall and the screws.

DIN-rail Mounting (Optional)
DIN-rail attachments can be purchased separately to attach the NPort W2x50A-W4 Series to a DIN rail. When snapping the attachments to the DIN rail, make sure that the stiff metal springs are at the top.

MOXA-NPort-W2150A-W4-NPort-W2250A-W4-Series-Wireless-Device-Servers-
fig-4

Software Installation
For the NPort’s configuration, the default IP address of the NPort is:

  • LAN : Static; IP = 192.168.126.254; netmask = 255.255.255.0
  • WLAN : Static; IP = 192.168.127.254; netmask = 255.255.255.0

If the NPort is configured for DHCP, but the DHCP server cannot be found, then the NPort will use the factory default IP settings

NOTE
If you have forgotten the NPort’s IP address, use the Device Search Utility (DSU) from your PC to locate the NPort. After searching the LAN for NPort units, the DSU will display the IP address of each unit.

NOTE

Ethernet Bridge Disabled (default): Only one network interface can be activated at a time. If the Ethernet link is active, the WLAN will be inactive. If the WLAN is active, the Ethernet link will be inactive.

Ethernet Bridge Enabled : The LAN and WLAN will both be active. Go to the web console, find the network settings page, and set Ethernet Bridge to Enabled

You may log in with the account name admin and password moxa to change any settings to meet your network topology (e.g., IP address) or serial device (e.g., serial parameters). For first-time use, click the Wizard in the left navigation panel. The wizard will prompt you to configure the IP address, SSID, and security mode. For other settings, use the factory defaults or change the settings for your application. For software installation, download the relative utilities from Moxa’s website: https://www.moxa.com/support/support_home?isSearchShow=1

  • Download the NPort Windows Driver Manager and install it as the driver to run with Real COM mode of the NPort Series.
  • Execute NPort Windows Driver Manager; then map the virtual COM ports on your Windows platform.
  • You may refer to the DB9 Male pin assignment section to loop back pin 2 and pin 3 for the RS-232 interface to carry out a self-test on the device.
  • Use HyperTerminal or a similar program (you may download Moxa’s program, called PComm Lite) to test whether the device is good or not.

Pin Assignments and Cable Wiring

Pin RS- 232 RS-422, 4w RS-485 2w RS-485
1 DCD TxD-(A)
2 RXD TxD+(B)
3 TXD RxD+(B) Data+(B)
4 DTR RxD-(A) Data-(A)
5 GND GND GND
6 DSR
7 RTS
8 CTS
9

Specifications

Power Requirements

Power Input| 12 to 48 VDC
Input Rating| 1- port: 12 to 48 VDC, max 429 mA @ 12 VDC

2- port: 12 to 48 VDC, max 455 mA @ 12 VDC

Power Connector| Screw-type power jack or terminal block (only one connection at a time)
Physical Characteristics
Material| Aluminum sheet metal (1 mm)
Dimensions| 77 × 111 × 26 mm (no ears, no antenna) 100 × 111 × 26 mm (with ears, no antenna)
Antenna Length| 108 mm
Magnetic Isolation| 1.5 kV magnetic isolation built in
Environmental Limits
Operating Temperature| Standard Models:

0 to 55°C (32 to 131°F), 5 to 95%RH

Wide Temp. Models:

-40 to 75°C (-40 to 167°F), 5 to 95%RH

Storage

Temperature

| -40 to 85°C (-40 to 185°F), 5 to 95%RH

Technical Support Contact Information www.moxa.com/support

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>