DOSATRON D25RE09-11GPM Rebuild Kit Instructions
- June 9, 2024
- DOSATRON
Table of Contents
DOSATRON D25RE09-11GPM Rebuild Kit
Instructions Part 1 – Seal Kit
(Parts included in kit noted in blue)
- Remove the 4 screws (M101) at base of the unit. Pull dosing stem straight out to remove.
- Unscrew the suction hose nut (PDI038) and check valve nut (PDI036). Pull out the check valve assembly (PJDI026) noting orientation of inner check valve cone with spring.
- Unscrew locking nut (PDI381) and remove locking ring (P189). Remove black adjusting sleeve (P167U1) and metal mounting collar (M079). Push firmly from below to release inner white stem (PDI583) from graduated sleeve (P165).
- Pinch and remove injection stem o-ring (JDI098) from white stem (PDI583) and replace with new o-ring.
- Pinch to remove and replace the graduated sleeve o-ring (J024) from the graduated sleeve (P165).
- 6. Insert the injection stem (PDI583) into the top of the graduated sleeve (P165). Push firmly down on injection stem as far as it will go. Make sure the long groove in the injection stem aligns with the tooth inside the graduated sleeve.
- Slide metal mounting collar (M079) over graduated sleeve (P165) and injection stem (PDI583). Screw adjusting sleeve back onto graduated sleeve (P165) enough to expose locking ring grooves in lower, threaded area of injection stem (PDI583). Align inner teeth on locking ring (P189) with exposed grooves on lower injection stem (PDI583) and slide up grooves to the base of adjusting sleeve (P167U1)
- Screw locking nut (PDI381) back onto injection stem assembly. Insert new check valve assembly (PJDI026) noting orientation of inner check valve cone with spring into exposed injection stem. Screw on the check valve nut (PDI036) and replace suction hose nut (PDI038).
- Pinch the plunger seal to remove it and replace it with the new plunger seal (JDI106).
- Align the ratio guide to the front and reinsert injection stem assembly.
- Align the metal collar (M079) with the holes in the body. Install the four screws using a #2 Phillips screw driver. Remove suction hose nut (PDI038) and reattach suction hose onto check valve barb. Reattach suction hose nut (PDI038).
To ensure hose is air-tight, you may choose to carefully cut the top of hose before reinserting.
Piston Kit
(Parts included in kit noted in blue)
- Remove the blue lid.
- Lift piston from unit.
- move screw (8M003) and wishbone holder (P394) from wishbone valve assembly (MP178). Slide inlet valve out from its secure clip-onwishbone assembly (MP178).
- Remove the 4 screws from the middle of the shell. The mechanism will drop out.
- Remove the Actuator Springs (M238) and replace.
- Replace the mechanism into new Piston Shell (P421). Make sure to tighten screws while holding mechanism from below to ensure a secure, flush fit against inside surface of piston shell (P421).
- Clip wishbone assembly (MP178) back into its proper position on top of inlet valve. Secure back of wishbone assembly by installing wishbone holder (P394) and securing with screw (8M003).
- Call at 1-800-523-8499 or 1-727-443-5404
- Visitwww.dosatronusa.com
Read User Manual Online (PDF format)