nVent DT115040R DT1 DIN Surge Protection Class I Plus II Owner’s Manual

June 9, 2024
nVent

nVent DT115040R DT1 DIN Surge Protection Class I Plus II

CERTIFICATIONS

FEATURES

  • Compact, yet high surge rated pluggable design, using minimum DIN rail width
  • External back-up fuse is not required up to 315 A (IEC only)
  • Retaining clip ensures enhanced vibration and shock resistance performance
  • Red/Green status indication and change-over contacts standard for remote monitoring

PRODUCT ATTRIBUTES

  • Nominal System Voltage (Un): 120 V
  • Max Continuous Operating Voltage (Uc): 150 V
  • Nominal Discharge Current (In), IEC: 20 kA 8/20 μs
  • Max Discharge Current (Imax), IEC: 50 kA 8/20 μs
  • Impulse Current (Iimp): 12.50 kA 10/350 μs
  • Voltage Protection Level (Up): 1,000 V
  • Response Time: 25 ns Max
  • Short Circuit Current Rating (Isccr): 25 kA;50 kA
  • Frequency: 50 – 60 Hz
  • Back-Up Fuse @ Isccr: 250 A @ 50 kA;315 A @ 25 kA
  • Protection Modes: L-N;N-PE
  • Temporary Over Voltage 120 min (Ut/mode): 229 V Safe Fail
  • Temporary Over Voltage Withstand 5 s (Ut): 175 V
  • Voltage Protection Rating (VPR): 500 V
  • Nominal Discharge Current (In), UL: 20 kA 8/20 μs
  • Replacement Module: DT1150M
  • Short Circuit Current Rating (SCCR): 200 kA
  • Technology: Thermal Disconnect
  • Torque: 3.32 ft lb
  • Connection, Stranded: #4 Max
  • Connection, Solid: #2 Max
  • Humidity: 5 – 95 % RH
  • Temperature: -31 to 185 °F
  • Enclosure Material: UL® 94V-0 Thermoplastic
  • Enclosure Rating: IP 20
  • Mounting: 35 mm top hat DIN rail
  • Status Indication: Mechanical flag
  • Remote Contacts: Yes
  • Remote Contact Switching Capacity: 0.5 A @ 12 VDC;0.5 A @ 24 VDC;0.5 A @ 48 VDC;1.0 A @ 125 VAC;1.0 A @ 250 VAC
  • Depth: 3.350″
  • Height: 3.540″
  • Width: 2.840″
  • Unit Weight: 1.396 lb
  • Certification Details: UL® 1449 Edition 4 Type 1CA
  • Complies With: EN 61643-11 Type 1, Type 2;IEC® 61643-11 Class I, Class II

DIAGRAMS

WARNING

nVent products shall be installed and used only as indicated in nVent’s product instruction sheets and training materials. Instruction sheets are available at www.nvent.com and from your nVent customer service representative. Improper installation, misuse, misapplication or other failure to completely follow nVent’s instructions and warnings may cause product malfunction, property damage, serious bodily injury and death and/or void your warranty

North America
+1.800.753.9221
Option 1 – Customer Care
Option 2 – Technical Support

Our powerful portfolio of brands:
nVent.com CADDY ERICO HOFFMAN RAYCHEM SCHROFF TRACER their respective owners.
nVent reserves the right to change specifications without notice