24V TRACE Vertical
Installation Guide
Profiles:
TRACE™ is an indoor/outdoor low voltage lighting system used primarily for direct or indirect lighting designs.
Please verify the contents of the packages!
Please read instructions entirely before starting installation
Be sure power is turned off before installing the system Call Tivoli, LLC tech
support with questions
Caution: TRACE™ is designed to work with listed Class 2 24V DC transformers
only. Use of any other power source will cause damage, shorten the life of the
fixture and will void the warranty.
Consult any and all applicable local and national codes for installation.
Do not conceal or extend exposed conductors through a building wall as per
local electrical code.
Warning: With any luminaire for any application, basic safety precautions
should always be followed to reduce the risk of fire, electric shock and
personal injuries. This lighting system should be installed by a certified
professional.
WARNINGS
TRACE™ MAY BE EASILY DAMAGED! The reliability of the product can only be
ensured if these warnings and cautions are complied with faithfully. Keep
these instructions for future maintenance work.
WARNING! Risk of product damage.
Longer runs of Trace™ lighting strands must be installed by at least two
people.
IMPORTANT! The Trace™ luminaire must not be allowed to bend or hang down.
That way, the bending limit will not be inadvertently exceeded, resulting in
product damage.
Keep Trace™ from twisting or bending in the wrong direction.
Two person installation.
Warning! Risk of product damage.
Trace™ Vertical must not be bent at less than 3.5” diameter or damage will
result. Do not allow Trace™ to twist or bend in the wrong direction.
WARNING! Risk of Damage.
Insert Trace™ Vertical into channel evenly and gradually to keep twisting and
bending to a minimum.
Overview: Read Before Installing Luminaire
Installation Notes:
Step 1: Measure run area where Trace™ is to be installed. Locate power feed
end at highest point of the run to minimize exposure to water run off.
Step 2: A Mounting Channel is recommended for outdoor applications. Lay
channel along desired area and attach with screws (by others) every 18 to 24
inches. If the design requires creating bends and arcs, it is recommended
that the Vertical Notched Channels are used. Mounting Clips are for use on
indoor applications only.
Note: Minimum bending diameter for the notched channel is 11”.
Trace™ lighting strand must not be bent at less than 3.5” diameter or damage
will result.
Step 3: Trace™ must be installed with two people. One to press the luminaire
into the channel and the other to hold the spool and unroll it while keeping
the Trace™ flex body straight.
Warning: Risk of Product damage.
Do not stretch, pull, or yank. Doing so can damage the Trace™ internal
connections and void the warranty.
Step 4: The Power Feed Connectors and End cap will overhang outside the ends
of the Channel. Measure length of Trace Run and cut 2.25” off the length of
the mounting channel. Insert Trace™ into mounted channel starting from power
connector end. Trace™ should be pressed into the channel carefully and
gradually, without excessive bending or damage will result.
Note: We recommend using a dry spray lubricant, such as 3M Spray Lubricant or
WD-40 Specialist for all Trace™ installations to insure the luminaire fits
into the channel without damage. Additionally, when installing with Mounting
Clips, Silicone Sealant (FLXD-SIL- GE-10) may be applied to the inside bottom
surface.
Step 5: Secure power connection to building with use of C-clamp (by others) or
mount connection inside J-Box.
Connect to 24V DC power supply according to supplied wiring diagrams.
Trace™ Mounting Options
Trace™ Vertical with Mounting Clips
Warning: Risk of Product Damage.
Only bend the Trace™ Vertical so the lens bends up or down. See diagram below.
Note: Minimum bending diameter for Trace™ Vertical is 3.5” in the vertical
direction only.
Step 1: Determine where the Mounting Clips will need to be installed to
achieve the desired shape.
Step 2: Position the Mounting Clips and attach with screws (Included).
Step 3: Lay a bead of Silicone Adhesive (LFXD-SIL-GE-10) to the inside bottom
surfaces of the Mounting Clips, as shown.
Step 4: Spray Dry Lubricant on a rag and wipe the inside upper surfaces of the
mounting clips, as shown, to allow the Trace™ fixture to slide more easily
into the mounting clip. 3M Spray Lubricant or WD-40 Specialist is
recommended.
Warning! Risk of Product Damage.
Regular WD40 490002 will stress craze, crack or swell the Trace™ Silicone
covering. Do not use!
Step 5: Trace™ must be installed with two people. One to press the luminaire
into the channel and the other to hold the spool and unroll it while keeping
the Trace™ flex body straight.
Step 6: Press the Trace™ into the Mounting Clips.
Step 7: Connect to power.
Bending Limitations
Warning! Risk of Product Damage.
Trace™ Vertical can only be bent in the direction that does not twist the Tape
Light.
Install Trace™ Vertical in Notched Mounting Channel
Warning: Risk of Product Damage.
Only bend the Trace™ Vertical so the lens bends up or down so as not to twist
the Tape Light. See diagrams.
Note: Minimum bending diameter for the notched channel is 11”.
However, the minimum bending diameter for Trace Vertical is 3.5” in the
vertical direction only.
Step 1: Determine Channel mounting Location.
Step 2: Drill a hole 3” from each end of the Channel and 18”-24” along length
of Channel.
Step 3: Position the Notched Channel and attach with screws (Included).
Step 4: Spray dry lubricant on a rag and wipe along the inside upper surfaces
of the extrusion. We recommend using a dry spray lubricant, such as 3M Spray
Lubricant or WD-40 Specialist for all Trace™ installations to insure the
luminaire fits into the channel without damage.
Step 5: Trace™ must be installed with two people. One to press the luminaire
into the channel and the other to hold the spool and unroll it while keeping
the Trace™ flex body straight.
Step 6: Start by orienting the Trace™ with the Lens facing away from the
Channel, as shown.
Step 7: Insert the Trace™ body into the Channel one flex section at a time.
Start at one end and and press it down carefully and gradually, working along
the Channel, inserting the Trace™ body into each section until the entire
Trace™ fixture is securely mounted in the channel.
WARNING! Risk of Product Damage.
Do not hammer or pound the luminaire into the channel. Once inserted, do not
pull or yank on the fixture. Trace™ will be damaged unless it is handled
carefully.
Step 8: Connect to power.
Bending Limitations
Warning! Risk of Product Damage.
Trace™ Vertical can only be bent in the direction that does not twist the Tape
Light.
Straight Channel for Trace™ Vertical Installation
Step 1: Prepare Straight Mounting Channel for installation cutting it to the
correct length, keeping in mind that the End Caps will not fit inside the
Channel, and by drilling screw holes 3” from each end and additional holes
approximately every 18” along the channel.
Step 2: Place Straight Channel on the mounting surface and mark the hole
locations.
Step 3: Remove the Channel and drill pilot holes at all hole locations.
Step 4: Place the Channel into position and secure with screws (not included).
Note: Screws (by others) should be appropriate for the mounting location. (ie:
wood screws for wood, etc.)
Step 5: Spray dry lubricant on a rag and wipe along the inside upper surfaces
of the extrusion. We recommend using a dry spray lubricant, such as 3M Spray
Lubricant or WD-40 Specialist for all Trace™ installations to insure the
luminaire fits into the channel without damage.
Step 6: Trace™ must be installed with two people. One to press the luminaire
into the channel and the other to hold the spool and unroll it while keeping
the Trace™ flex body straight.
tep 7: Start by orienting the Trace™ with the Lens facing away from the
Channel, as shown.
Step8: IMPORTANT! Insert the Trace™ body into the Channel. Start at one end
and and press it down carefully and gradually, working along the Channel,
inserting the Trace™ body along the channel until the entire Trace™ fixture
is securely mounted in the channel.
WARNING! Risk of Product Damage.
Do not hammer or pound the luminaire into the channel. Once inserted, do not
pull or yank on the fixture. Trace™ will be damaged unless it is handled
carefully.
Step 9: Connect to power.
Bending Limitations
Warning! Risk of Product Damage.
Trace™ Vertical can only be bent in the direction that does not twist the Tape
Light.
Note: Trace™ Mounting Channel can be mounted on horizontal or vertical surfaces.
LUMINAIRE | MAX CONTINUOUS RUN LENGTH |
---|---|
Trace™ Horizontal and Vertical | Low Output |
58’ | 58’ |
Power Supply with 0-10V Sample Wiring Diagram
There are many possible options for dimming Trace™. See the specification Sheet for more information. The following wiring diagram is for reference only. Please refer to the Installation Instruction for the Power Supply you choose for detailed wiring instructions.
Copyright © 2022 Tivoli 08.08.22
7101002
www.tivolilighting.com
tel:714-957-6101 fax:
714-427-3458
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>