Thank you for selecting ViewStar AU series solar charge controller. Please read this manual carefully before using the product.
Overview
Thank you for selecting the ViewStar AU series common positive solar charge controller. The VS-AU controller is a PWM charge controller with built in LCD display that adopts the most advanced digital technique. The multiple load control modes enable it can be widely used on solar home system, traffic signal, solar street light, solar garden lamp, etc. The features are listed below:
- Adopt high quality components of ST,IR and Infineon, make sure product using lifespan
- Terminals have UL and VDE certification, the product is more safer and more reliable
- Controller can work continuously at full load within the environment temperature range from -25 to 55 ℃
- 3-Stage intelligent PWM charging :Bulk, Boost/Equalize, Float
- Support 3 charging options: Sealed, Gel, and Flooded
- LCD display design, dynamically displaying device’s operating data and working condition
- Double USB design, the power supply charge for electronic equipment
- With humanized button settings, operation will be more comfortable and convenient
- Multiple load control modes
- Energy statistics function
- Battery temperature compensation function
- Extensive Electronic protection
Product Features
(1) | LCD | (5) | Battery Terminals |
---|---|---|---|
(2) | MENU Button | (6) | Load Terminals |
(3) | RTS Port | (7) | SET Button |
(4) | PV Terminals | (8) | USB Output Ports |
※ USB output ports provide the power supply of 5VDC/2.4A and have the short circuit protection.
Optional Accessory:
Name: Remote Temperature Sensor
Model: RTS300R47K3.81A
Acquisition of battery temperature for undertaking temperature compensation of
control parameters, the standard length of the cable is 3m (length can be
customized). The RTS300R47K3.81A connects to the port ③ on the controller.
NOTE: Unplug the RTS, the temperature of battery will be set to a fixed
value 25ºC.
Wiring
- Connect components to the charge controller in the sequence as shown above and pay much attention to the “+” and “-”. Please don’t insert the fuse or turn on the breaker during the installation. When disconnecting the system, the order will be reserved.
- After power on the controller, check the LCD on. Otherwise please refer to chapter 6.Always connect the battery first, in order to allow the controller to recognize the system voltage.
- The battery fuse should be installed as close to battery as possible. The suggested distance is within 150mm.
- The VS AU series is a positive ground controller. Any positive connection of solar, load or battery can be earth grounded as required.
NOTE: Please connect the inverter or other load that it has the large start current to the battery rather than to the controller, if the inverter or other load is necessary.
Operation
4.1 Button Function
Button | Function |
---|---|
MENU button | • Browse interface |
• Setting parameter
SET button| • Load ON/OFF
• Clear error
• Enter into Set Mode
• Save data
4.2 LCD Display
Status Description
Item Icon Status PV array Day Night No charging Charging PV Voltage,
Current ,Power Battery Battery capacity, In Charging Battery voltage. current,
temperature Battery type Load Load ON Load OFF Load Voltage, Current, Load
mode.
Item | Icon | Status |
---|---|---|
PV array | Day | |
Night | ||
No charging | ||
Charging | ||
PV Voltage, Current ,Power | ||
Battery | Battery capacity, In Charging | |
Battery voltage. current, temperature | ||
Battery type | ||
Load | Load ON | |
Load OFF | ||
Load Voltage, Current, Load mode |
Browse interface
NOTE:
-
When no operation, the interface will be automatic cycle, but the follow two interfaces not be display.
-
Accumulative power zero clearing: Under PV power interface, press SET button and hold on 5s then the value blink, press SET button again to clear the value.
-
Setting temperature unit: Under battery temperature interface, press SET button and hold on 5s to switch.
Fault Indication
Status | Icon | Description |
---|---|---|
Battery over discharged | Battery level shows empty, battery frame blink, |
fault icon blink
Battery over voltage| | Battery level shows full, battery frame blink, fault
icon blink
Battery Overheating| | Battery level shows current value, battery frame
blink, fault icon blink
Load failure| | Load overload ① ,Load short circuit
①When load current reaches1.02-1.05 times 1.05-1.25 times, 1.25-1.35 times and 1.35-1.5 times more than nominal value, controller will automatically turn off loads in 50s, 30s,10s and 2s respectively
4.3 Load mode setting
Operating Steps:
Under load mode setting interface, press SET button and hold on 5s till the
number begin flashing, then press MENU button to set the parameter, press SET
button to confirm.
NOTE: Please set Light ON/OFF, Test mode and Manual mode via Timer1.
Timerwill be disabled and display “2 n”.
4.4 Battery Type
Operating Steps
Under Battery Voltage interface, press SET button and hold on 5s then enter
into thinterface of Battery type setting. After choosing the battery type by
pressing MENU button, waiting for 5s or pressing SET button again to modify
successfully.
Battery Type
NOTE: Please refer to the battery voltage parameters table for the different battery type.
Protections
Protection | Conditions | Status |
---|---|---|
PV Reverse Polarity | When the battery is correct connecting, the PV can be | |
reversed. | The controller is not damage | |
Battery Reverse Polarity | When the PV is not connecting, the battery can be |
reversed.
Battery Over Voltage| The battery voltage reaches to the OVD| Stop charging
Battery Over Discharge| The battery voltage reaches to the LVD| Stop
discharging
Battery Overheating| Temperature sensor is higher than 65t| Output is OFF
Temperature sensor is less than 55t| Output is ON
Controller Overheating| Temperature sensor is higher than 85t| Output is OFF
---|---|---
Temperature sensor is less than 75t| Output is ON
Load Short Circuit| Load current ?2.5 times rated current One short circuit,
the output is OFF 5s: Two short circuit, the output is OFF 10s: Three short
circuit, the output is OFF 15s: Four short circuit, the output is OFF 20s:
Five short circuit, the output is OFF 25s: Six short circuit, the output is
OFF| Output is OFF
Clear the fault: Restart the controller or wait for one night-day cycle (night
time>3 hours).
Load Overload| Load current .2.5 times rated current 1.02-1.05 times, 50s,
1.05-1.25 times, 30s
1.25-1.35 times,10s
1.35-1.5 times 2s
night-day cycle| Output is OFFClear the fault:
Restart the controller or wait for one
(night time>3 hours).
Damaged RTS| The RTS is short-circuited or damaged| Charging or
discharging at 25t
Troubleshooting
Faults | Possible reasons | Troubleshooting |
---|---|---|
The LCD is off during daytime when sunshine falls on PV modules properly | PV | |
array disconnection | Confirm that PV wire connections are correct and tight |
Wire connection is
correct, LCD not
display| 1)Battery voltage is lower than 9V
2)PV voltage is less than battery voltage| 1)Please check the voltage of
battery. At least 9V voltage to activate the controller
2) Check the PV input voltage which should be higher than battery’s
Interface blink| Battery over voltage| Check if the battery voltage is higher
than OVD point (over voltage disconnect voltage), and disconnect the PV.
Interface blink| Battery over discharged| When the battery voltage is restored
to or above LVR point (low voltage reconnect voltage), the load will recover
Interface blink| Battery Overheating| The controller will automatically turn
the system off. But while the temperature decline to be below 50 QC, the
controller will resume.
Interface blink| Over load or Short circuit| Please reduce the number of
electric equipments or check carefully loads connection.
Disclaimer
This warranty does not apply under the following conditions:
- Damage from improper use or use in an unsuitable environment.
- PV or load current, voltage or power exceeding the rated value of controller.
- The controller is working temperature exceed the limit working environment temperature.
- User disassembly or attempted repair the controller without permission.
- The controller is damaged due to natural elements such as lighting.
- The controller is damaged during transportation and shipment.
Technical Specifications
Item| VS1024AU| I VS2024AU| I| VS3024AU|
VS3048AU| VS4524AU| VS4548AU| VS6024AU| VS6048AU
---|---|---|---|---|---|---|---|---|---
Nominal system voltage| 12/24VDC
Auto| | 12/24/36/48VDC
Auto| 12/24VDC
Auto| 12/24/36/48VDC
Auto| 12/24VDC
Auto| 12/24/36/48VDC
Auto
Battery input voltage range| 9V-32V| | 9V-64V| 9V-32V| 9V-64V| 9V-32V| 9V-64V
Rated charge /discharge current| 10A@55°C| I 20A@55°C| I| 30A@55°C| 45A©55t|
60A@55`C
Max. PV open circuit voltage| 50V| | 96V| 50V 96V| 50V| 96V
Battery type| Sealed(Default) / Gel / Flooded
Equalize Charging Voltagex| Sealed:14.6V/ Gel: No/ Flooded:14.8V
Boost Charging Voltagex| Sealed:14.4V/ Gel:14.2V/ Flooded:14.6V
Float Charging Voltagex| Sealed/Gel/Flooded:13.8V
Low Voltage Reconnect Voltagex| Sealed/Gel/Flooded:12.6V
Low Voltage Disconnect Voltagex| Sealed/Gel/Flooded:11.1V
Self-consumption| 59.2mA/12V;511.7mA/24V; 514.5mA/36V;517mA/48V
Temperature compensation coefficient| -3mV/t /2V ( 25°C )
Charge circuit voltage drop| 50.29V
Discharge circuit voltage drop| 50.16V
LCD temperature range| -20°C —+70°C
Working environment temperature| -25°C —+55°C (Product can work continuously
at full load)
Relative humidity| 595%, N.C.
Enclosure| IP30
Grounding| Common Positive
USB output| | 5VDC/2.4A(Total)
Overall dimension| 142x85x41.5mm| 160×94.9×49.3mm| 181×100.9×59.8mm|
194×118.4×63.8mm| 214×128.7×72.2mm
Mounting dimension| 130x6Omm| 148x70mm| 172x80mm| 185x90mm| 205x100mm
Mounting hole size| 04 5mm| 05mm| 05mm| 05mm
Terminals| 4mm2/12AWG| lOmm2/8AWG| 16mm2/6AWG| 16mm2/6AWG| 25mm2/4AWG
Net weight| 0.22kg| 0.350| 0.55kg| I 0.580| 0.76kg| I 0.880| 1.020| I 1.04kg
XAbove the parameters are in 12V system at 25r, twice in 24Vsystem, triple in
36V system and quadruple in 48V system.
Any changes without prior notice!
Documents / Resources
|
EPEVER VS1024AU Pwm Solar Charger
Controller
[pdf] User Manual
VS1024AU, VS3024AU, Pwm Solar Charger Controller, Charger Controller, Pwm
Solar Charger, Controller, Charger Controller
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>