PARTS

Front
1. Control Panel
2. Cooling Air Outlet
3. Remote Signal Receiver
4. Handle|
---|---
Back
5.Air filter
6. Air Inlet (Evaporator)
7. Exhaust Air Outlet
8. Air Inlet
9. Drain Plug and Drain|
---|---

Accessories
10. Extendable window spacer – To fill extra space in window (1)
11. Exhaust hose/Inlet hose- (2)
12. Hose adapter- For insertion over each end of hose (4)
13. Window spacer connector – For insertion into the hose adapter and mounted onto the extendable window spacer (2).
14. Cover- Used to place over the window spacer connector to block air when unit is not in use or for off season (2).

SAFETY PRECAUTIONS

  1. Only use in the upright position on a flat, level surface at least 20″/50cm from any object.
  2. WARNING- Please read the warning label on the power cord before handling the unit.
  3. Do not place objects on top or in front of the unit.
  4. Closely supervise children and pets while unit is in use.
  5. For indoor use only.
  6. Turn off and unplug the unit when it is not in use.
  7. Do not use in wet environments.
  8. Do not pull the unit by the cord.
  9. If the power cord is damaged, it must be replaced by an electrician to avoid hazard or injury.

FOR MAXIMUM EFFICENCY

  1. Do not exceed the recommended room size of 400 sq. feet.
  2. Keep doors and windows closed.
  3. Keep curtains or blinds closed during the sunniest part of the day.
  4. Keep filters clean.
  5. Once room has reached the desired condition, reduce the temperature.

INSTALLATION

  1. Connect one hose adapter to each end of the 2 hoses.
  2. Insert one hose into the exhaust air outlet and one hose into the air inlet.
  3. Insert the window spacer into the window.
  4. Mount the window spacer connector covering the holes on the extendable window spacer.
  5. Insert each hose into the window spacer.

NOTE: The hose may be extended from 1-5 ft/300-1500mm but for maximum efficiency use the shortest length possible.
For best results do not let the exhaust hose exceed a 45° angle.

OPERATION/FUNCTIONS

Control panel

  1. Water full indicator light

  2. Cool indicator light

  3. Dehumidify indicator light

  4. Fan indicator light

  5. Power button

  6. Mode button (Cool, Dehumidify, Fan)

  7. Speed button (High, Medium, Low)

  8. High indicator light

  9. Medium indicator light

  10. Low indicator light

  11. Display

  12. Temperature/Timer DOWN button

  13. Temperature/Timer UP button

  14. Timer button

  15. Room temperature indicator light

  16. Set temperature indicator light

  17. Timer indicator light

ON/OFF
Press this button to start and stop the unit..

MODE
Press this button to select the Fan, Cool or Dehumidify mode.
The Fan mode will allow you to select a Speed of High, Medium or Low.
The Cool mode will allow you to select a Speed of High, Medium or Low or a specific temperature by using the UP/DOWN buttons between 61°F-89°F (16°C -32°C).
The Dehumidify mode will allow you to dehumidify the room and remove excess moisture.

SPEED
Press the SPEED button to select a High, Medium or Low setting.

TIMER (1-12 Hours)
The timer button will allow you to turn the unit ON or OFF without even being in the room.
If the unit is OFF- Press the TIMER button on the control panel or remote control (Timer indicator light will be lit).
Then press the
or buttons on the control panel or the remote until you select the quantity of hours (1-12) you want the unit turned on in. Example- If you want the unit to turn on in 3 hours then press the button until it shows 3, the unit will automatically turn on in 3 hours.
If the unit is ON- Press the TIMER button on the control panel or remote control (Timer indicator light will be lit).
Then press the or buttons until you select the quantity of hours (1-12) you want the unit turned off in.
Example- If you want the unit to turn off after 4 hours then press the button until it shows 4, the unit will automatically turn off in 4 hours.

Water Full Indicator Light
When the water tank is full the water full indicator light will light up and the machine will automatically turn off.
Drain any water from the unit by removing the drain plug and emptying the water through the drain port into a suitable container.

REMOTE CONTROL

MAINTENANCE

Always unplug the air conditioner from the outlet before cleaning. To maximize the efficiency of the air conditioner, clean regularly.

Cleaning the Filte
Remove the filter from the back of the unit. Use a vacuum cleaner or gently tap the filter to remove loose dust and dirt, then rinse thoroughly under warm running water. Dry thoroughly before returning the filter to the correct position.
NOTE : Never operate the unit without the filter.

Cleaning the Housing
Use a soft, damp cloth to wipe the body clean.
Never use chemicals, gasoline, detergents, chemically treated cloths or other cleansing solutions as this could possibly damage the housing.

Storage

  • Drain any water from the unit by removing the drain plug and emptying the water through the drain port into a suitable container.
  • Clean the filter
  • If possible, place back in its original carton or cover for storage.
  • Always keep the unit in the upright position

TROUBLE SHOOTING

Problem Possible Cause/Solution
The air conditioner does not run Check to see if it is plugged in.

Check to see the power is on.
The machine is not cooling very well| Is there direct sunlight.
Close all curtains and blinds.
Check to make sure there are no doors/windows open.
Check to make sure nothing that produces heat is on.
The unit is vibrating| The unit may be on an uneven surface.
Make sure it is on a flat surface.
Sudden noise| The compressor may have turned on. This is normal.

* NOTE: Never try to repair or dismantle the unit yourself.

SPECIFICATION FOR ARP-900EX / 1000EX / 1200EX UNIT

Model ARP-900EX ARP-1000EX ARP-1200EX
BTU/Cooling 9000 10000 12000
Power/Ampere Consumption for cooling 950W / 8.7A 950W / 8.7A 1300W/11.5A
EER 9.0 9.0 9.
Air volume (max. speed) 380 380 420
Humidity removal capacity 1.6 Uh 1.6 Uh 1.8 Uh
Recommended room size 300 sq. ft. 350-400 sq. ft. 400 sq. ft.
Power supply 115V/60Hz/1 phase
Compressor Rotary
Refrigerant R22
Fan speed 3
Timer 1-12 hours
Thermostat 61°F-89°F
Unit weight 75 lbs. (34 kg) 75 lbs. (34 kg) 79.4 lbs. (36 kg)
Unit dimension 19.9 x 33.0 x 16.1 (in) / 505 x 839 x 408 (mm)
Carton dimension 22.0 x 41.7 x 18.5 (in) / 560 x 1060 x 470 (mm)

FULL ONE YEAR WARRANTY

Royal Sovereign warrants each Portable Air Conditioner to be free from defects in material and workmanship. Our obligation under this warranty is limited to the repair or replacement, free of charge, when delivered to an authorized Royal Sovereign service center, of any defective part(s) thereof, other than parts damaged in transit. This warranty is in effect to the original purchaser, for a period of one year from the date of purchase and is not transferable. This warranty shall apply only if the air conditioner is used on Alternating Current (AC) circuit, in accordance with the factory provided instructions which accompany it.

LIMITED FIVE YEAR WARRANTY (COMPRESSOR)

For a period of five years from the date of purchase, when this Royal Sovereign Portable Air Conditioner is operated and maintained according to the instruction manual provided with the product, Royal Sovereign will supply a replacement compressor (part only), free of charge, if the original compressor is determined to be defective in workmanship or material. If repair becomes necessary, please contact our customer service center. You will be responsible for all freight, insurance, and any other transportation charges to get the unit to our factory or service center. If shipping is required, be sure to pack the unit properly to avoid shipping damages, as we will not be responsible for such damages.

EXCLUSIONS

This warranty excludes and does not cover defects, malfunctions or failures of your Royal Sovereign Portable Air Conditioner, caused by repairs by unauthorized persons or service centers, mishandling, improper installation, modification or unreasonable use including incorrect voltage, acts of god, or failure to provide reasonable and necessary maintenance.
This warranty is in lieu of any and all expressed warranties. In no even shall Royal Sovereign be liable for consequential or incidental damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

ROYAL SOVEREIGN INTERNATIONAL, INC.
Royal Centurian Inc.
2 Volvo Drive Rockleigh, NJ 07647 USA
TEL : +1) 201-750-1020, 800-397-1025 FAX : +1) 201-750-1022

RS International Australia PTY. LTD.
30 Prime Drive, Seven Hills, NSW 2147, AUSTRALIA
TEL : +61) 2-9674-2127 FAX : +61) 2-9674-2027
www.royalsovereign.com / info@royalsovereign.com

Royal Sovereign Canada
164 Oakdale Road, Toronto, Ontario M3N 2S5 CANADA
TEL: +1) 416-741-8400 FAX: +1) 416-741-8185

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Royal Sovereign User Manuals

Related Manuals