Royal Sovereign RCAS-650 Professional Air Scrubber Owner’s Manual

June 3, 2024
Royal Sovereign

Owner’s Manual
PROFESSIONAL AIR SCRUBBER
RCAS-650Royal Sovereign RCAS 650 Professional Air
Scrubber

RCAS-650 Professional Air Scrubber

IMPORTANT: Please read all instructions and warnings carefully before installation and use. Failure to follow these instructions may result in a possible electric shock, injury to persons, or possible fire hazard. It will also void the warranty.
Royal Sovereign International Inc.
Because our products are subject to continuous improvement,
Royal Sovereign reserves the right to modify product design and specifications without notice and without incurring any obligation. E&OE

SAFETY INSTRUCTIONS

Read all instructions before use.
We have provided many important safety messages in this manual. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can hurt you and others.
All safety messages will follow the safety alert symbol and either the word “WARNING” or “CAUTION”. These words mean:
WARNING This symbol indicates the possibility of death or serious injury.
CAUTION This symbol indicates the possibility of injury or damage to property.
WARNING: To reduce the risk of fire, electric shock, or injury to persons when using this unit, follow basic precautions, including the following:

  • Do not use the unit in standing water.
  • Unplug the unit before servicing or changing filters.
  • Do not block air intake or outlet. 12″ (30cm) minimum distance to obstructions.
  • Do not operate the unit with a damaged cord or plug.
  • Unit should be connected to a GFCI outlet.
  • Do not use an extension cord.
  • Unit must be electrically grounded
  • If electrical parts get wet, they must be dried prior to use
  • Do not run the cord under the carpet. Do not cover the cord with throw rugs, runners, or similar coverings.
  • Arrange the cord away from traffic areas where it will not be tripped over.
  • Do not allow children to play with or around the unit
  • Do not move or carry the unit while the unit is operating.
  • Keep air intakes and exhausts clean at all times. Avoid clogging or blocking to prevent the unit from overheating.
  • Always place the unit on a smooth and level surface for safe operation.

**** When transporting the air scrubber from project to project, the unit should be transported vertically or horizontally on the appropriate feet located on the bottom of the unit or opposite handle. Ensure that the unit is plugged into a grounded 15A circuit.
The unit draws about 2A when in operation and has no ducting. The amp draw will decrease slightly with added ducting and/or as the filters get dirty. No extension cords should be used.
This instruction sheet is not meant to cover all possible conditions and situations that may occur. Caution and care must be used with any electrical product.

PRODUCT OVERVIEW

Royal Sovereign RCAS 650 Professional Air Scrubber - PRODUCT
OVERVIEW

  1. Air Outlet (ductable, 10″)
  2. Latches (used to access filters)
  3. Inlet Removeable Cover / Air Inlet (ductable, 12″)
  4. Handle
  5. HEPA filter (located inside unit)
  6. Pre- filter (located inside unit)
  7. GFCI outlets
  8. Circuit break switch
  9. Filter Change Indicator Light
  10. UV-C Light ON/OFF
  11. Variable speed control

The unit draws air through two types of filters – a pre-filter and a HEPA filter.
Pre-filter
The pre-filter is the first stage of filtration. The pre-filter caputres initial dust and allergens particales.
HEPA filter
The HEPA filter is the second stage of filtration. It captures 0.3sized and larger microns at a 99.97% rate.
UV-C Light
The unit is equipped with UV-C light technology which works with filters to enhance the elimination of airborne germs.
Optional Carbon Filters
A carbon filter
Used to help remove odors such as smoke remediation odors, soot, paint fumes, and airborne VOCs. It is used in place of the pre-filter.
GFCI Outlet
The GFCI outlets allow for up to 2 additional devices, such as additional air scrubbers or an air blower to be connected to the unit as long it does not go above the max amperage The maximum amperage of 12 when the unit is turned OFF and a maximum of 9 amps when the units are turned on.
Note: To check to see if the GFCI outlet is working properly, power on the unit and press the RED GFCI test button. If the outlet is working properly, the reset button will pop up. To operate, press the reset button again.
Circuit Breaker Switch
The circuit breaker switch protects the unit if there is more than 12 amps of electricity passing through the circuit. If this occurs, the switch will cut off the power to the unit.
Change Filter
The change filter light will turn on when the HEPA filter is dirty and needs replacement.
ON/OFF
This is the ON/OFF button to turn ON/OFF the UV-C light.
The variable speed control
Used to adjust the power of the unit. Turn the knob to adjust the speed.

OPERATION

  1. Place the unit so that it is in the upright vertical position.
  2. Remove the cover.
  3. Plug the unit into a standard electrical outlet. Note: Each unit needs 2.22 amps to operate.
  4. Turn the unit on and adjust the speed of the variable speed control. Turn ON the UVC-Light technology feature if desired.
  5. The air scrubber can be operated in the vertical or horizontal position depending on the application. Adjust the unit to the desired position.

CAUTION: Do not remove HEPA filter while the air scrubber is in operation. Always disconnect the air scrubber before changing filters.
Removing the top and filters while in operation will expose the impeller fan.

AIR DUCTING

Inlet Ducting – If using the commercial air scrubber for air ducting, a round 12″ round diameter flexible duct can be attached to the unit inlet. Connect by placing the wire in the duct over the duct collar lip. After use, remove it for easier storage and transportation.
Outlet Ducting – A detachable trapezoid-shaped exhaust ring is supplied that will allow a 10″ round lay flat plastic duct to be attached to the air scrubber outlet. To attach the collar, remove the ring from the unit by pressing the release tab at the top of the grill. Place the plastic duct end through the inside of the ring. Roll the duct end outward so that it overlaps the outside of the ring. Clip the ring back onto the exhaust grill.
NEGATIVE AIR DUCTING
Filtering and exhausting air from space will cause the space to be under slight negative pressure. This will help prevent airborne particles from leaving the space, as the negative pressure will draw air in through openings in the space’s exterior surfaces.
CAUTION: Exhausting too much air from space with open combustion devices, can potentially cause a backdraft. This can contaminate the space with potentially dangerous gas.

MAINTENANCE

WARNING: Use extreme caution when changing the HEPA filter as a hazardous material could be trapped in the media.
WARNING: Always wear NIOSH-compliant protective gear when changing filters and dispose of used filters according to your local regulations.
Air Filters
It is recommended that filters should be changed after every remediation job and whenever the filter change indicator light comes on.
The unit should also be cleaned after each job to prevent cross-contamination.
The filters should be checked regularly to ensure optimum operation. Operating the unit with dirty filters will reduce the airflow and operation of the unit. Make sure the unit is dry prior to installing clean filters.
To change the HEPA Filter, proceed as follows:

  1. Rotate the two clips

  2. Carefully remove the HEPA filter.
    Important Note: Refer to the warnings when changing filters.

  3. Install the new filter

  4. Reattach and tighten the two clips.
    Note: The life of filters is dependent on the number of hours used and the contamination level.

TROUBLE  SHOOTING

Trouble Cause Solution
Motor not running Switched Off Ensure the unit is plugged in and the unit is

ON
Power failure| Check outlet/change to another outlet
Other| Contact Royal Sovereign customer service
Scraping noise from the fan| Obstruction at the intake or exhaust of the fan| Remove obstruction
Fan broken| Contact Royal Sovereign customer service
Weak airflow| Obstructed inlet/outlet and/or filters| Clean inlet/outlet or change filters
Change light illuminated| Dirty filters| Replace HEPA filter

SPECIFICATIONS

Feature RCAS-650
CFM 650
Material Rugged into molded polypropylene plastic
Pre liter Yes
Helm Fifer Yes (Captures 0.3 sized and larger at a 99.97% rate)
Carbon Filter Optional
Variable Speed Control Yes
Change Filter Indicator Light Yes
Circuit Breaker Switch Yes
CFO receptacles 2
Daisy Chain Upto4
Stackable Up to 5
Operation Horaont al or Vertical operation
Effective Application Area BOO sot (139 so rn)
Horsepower 1/3 HP
Duct Size Intake/Outtake 1T/10*
Amperage 2.22A
Unit Dimensions 51 x 37 x 57cm PO’ x 14.6″ x 22.41
Weight 13.9cg (20.71bs)

WARRANTY

Royal Sovereign warrants this product to be free from defects in material and workmanship. Our obligation under this warranty is limited to the repair or replacement, free of charge, when delivered to an authorized Royal Sovereign service center, of any defective part(s) thereof, other than parts damaged in transit.
This warranty is in effect to the original purchaser, for a period of one year from the date of purchase and is not transferable.
This warranty shall apply only if the product is used in accordance with the factory provide instructions that accompany it.

EXCLUSIONS

This warranty excludes and does not cover defects, malfunctions, or failures of this product, caused by repairs by unauthorized persons or service centers, mishandling, proper installation, modification or unreasonable use including incorrect voltage, acts of God, or failure to provide reasonable and necessary maintenance. This warranty is in lieu of any and all expressed warranties. In no event shall Royal Sovereign be liable for consequential or incidental damages. This limitation would not apply if you live in a location that does not permit the exclusion or limitation of incidental or consequential damages.

ROYAL SOVEREIGN INTERNATIONAL, INC.
2 Volvo Dr., Rockleigh, NJ 07647 USA
TEL: +1) 800-397-1025
Email: info@royalsovereign.com
RS INTERNATIONAL CANADA INC.
191 Superior Blvd, Mississauga Ontario L5T2L6 CANADA
TEL : +1) 905-461-1095 TF # : +1) 866-961-6673
FAX : +1) 905-461-1096
www.royalsovereign.ca
Because our products are subject to continuous improvement,
Royal Sovereign reserves the right to modify product design and specification without notice and without incurring any obligation E&OE.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Royal Sovereign User Manuals

Related Manuals