MARK LIGHTING S2WI Indirect Wall Light Instruction Manual

June 9, 2024
MARK LIGHTING

MARK LIGHTING logo S2WI Indirect Wall Light
Instruction Manual

MARK LIGHTING S2WI Indirect Wall Light

Important Safety Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
  • Installation and service of luminaires should be performed by a qualified licensed electrician.
  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit.
  • Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

WARNING
RISK OF ELECTRIC SHOCK
✓ Disconnect or turn off power before installation or servicing.
✓ Verify that supply voltage is correct by comparing it with the luminaire label information.
✓ Make all electrical and grounded connections in accordance National Electrical Code (NEC) and any applicable with the local code requirements.
✓ All wiring connections should be capped with UL approved recognized wire connectors.

WARNING
RISK OF BURN
✓ Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.
✓ Do not exceed maximum wattage marked on luminaire label.
✓ Follow all manufacturer’s warnings, and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling. recommendations
CAUTION
RISK OF INJURY
✓ Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
✓ Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF FIRE
✓ Keep combustible and other materials that can burn, away from lamp/lens.
✓ Do not operate in close proximity to persons, combustible  materials or substances affected by heat or drying.

CAUTION: RISK OF PRODUCT DAMAGE
✓ Never connect components under load.
✓ Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
✓  Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility
with the luminaire prior to installation. LED fixtures must be powered directly o ffa switched circuit.
✓  Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture.
Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
✓ Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
✓  Only use fixture in its intended location.
✓  LED products are Polarity Sensitive. Ensure proper Polarity before installation.
✓  Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
✓  Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
✓  Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
✓  Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
✓ Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.
✓ Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.
Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference
(2) This device must accept any interference received, including interference that may cause undesired operation
This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
Installation and service should be performed by a qualified licensed electrician.
Maintenance should be performed by qualified person(s) familiar with the products’ construction and operation and any hazards involved. Regular maintenance programs are recommended.
DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
✓ Disconnect or turn off power before installation or servicing.
✓ Verify that supply voltage is correct by comparing it with the luminaire label information.
✓ Make all electrical and grounded connections in accordance National Electrical Code (NEC) and any applicable with the local code requirements.
✓ All wiring connections should be capped with UL approved ecognized wirez connectors.
CAUTION
RISK OF INJURY
✓ Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.
✓ Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF BURN
✓ Allow lamp/fixture to cool before handling.Do not touch enclosure or light source.
✓ Do not exceed maximum wattage marked on luminaire label.
✓ Follow all manufacturer’s warnings,recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.
CAUTION
RISK OF FIRE
✓ Keep combustible and other materials that can burn, away from lamp/lens.
✓ Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
CAUTION: RISK OF PRODUCT DAMAGE

  • Electrostatic Discharge (ESD): ESD can damage product(s). Personal grounding equipment must be worn during all installation or servicing of the unit.
  • Do not touch individual electrical components as this can cause ESD and affect product Performance.
  • Do not stretch or use cable sets that are to short or are of insufficient length.
  • Do not tamper with contacts.
  • Do not modify the product.
  • Do not change or alter internal wiring or installation circuitry.
  • Do not use product for anything other than its intended use.
  • If installing latching springs: ensure that the springs are fully engaged prior to moving to next connection.
  • If installing wiring systems: Materials and component parts of a manufacturing wiring system as described in Article 604 of the National Electric Code and Underwriters Laboratories Standard for Safety #183 MUST BE installed.

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com

Our Brands| Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting| Controls
DARK TO LIGHT
LC&D ROAM
Sensor Switch Synergy
---|---|---
Indoor/Outdoor
Lithonia Lighting
Carandini
Holophane
RELOC
Light Concepts| Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen| Daylighting
SunOptics
Pre-Launch

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

Overview – Fixture

Do not join fixtures together on the floor.
NOTE: Illustrations are used for reference only and can differ slightly from the actual lighting system installed.
However, key components addressed in this information are represented as accurately as possible.
WARNING: DO NOT LOAD SINGLE FEED TO MORE THAN 6 AMPS   MARK LIGHTING
S2WI Indirect Wall Light - fig 26

Overview Mounting

Individual Fixture Configurations

MARK LIGHTING S2WI Indirect Wall Light - fig 25

INDIVIDUAL UNITS (MOUNTING)


LENGTH| “A” O.A.L| “B” O.C.|

“C” FROM END

2FT| 2’- 0 9/16″| 1’- 1″| 5 3/4”
3FT| 3’- 0 9/16″| 2’- 1″| 5 3/4”
4FT| 4’- 0 9/16″| 3’- 1″| 5 3/4”
5FT| 5’- 0 9/16″| 4’- 1″| 5 3/4”
6FT| 6’- 0 9/16″| 5’- 1″| 5 3/4”
7FT| 7’- 0 9/16″| 6’- 1″| 5 3/4”
8FT| 8’- 0 9/16″| 7’- 1″| 5 3/4”

O.A.L – Overall lenght
O.C. – Distance from center to center

MARK LIGHTING S2WI Indirect Wall Light - fig 24

Run ConfigurationsMARK LIGHTING S2WI Indirect Wall Light - fig
23

RUN LAYOUT (MOUNTING)

“A1” O.A.L| “A2” O.A.L.| “B” FEED POINTS| “C” FROM END| “D”
4’- 0 1/4”| 4’- 0”| 3’- 1”| 5 3/4”| 11”
5’- 0 1/4”| 5’- 0”| 4’- 1”| 5 3/4”| 11”
6’- 0 1/4”| 6’- 0”| 5’- 1”| 5 3/4”| 11”
7’- 0 1/4”| 7’- 0”| 6’- 1”| 5 3/4”| 11”
8’- 0 1/4”| 8’- 0”| 7’- 1”| 5 3/4”| 11″

Prep Fixtures and Parts

MARK LIGHTING S2WI Indirect Wall Light - fig 21

  • Labels are located on the carton, on the fixture, and on the len
  • Each section is identified by and ID#.
  • Section position starting with X.000 for the first fixture.
  • Same fixture configuration can carry identical ID# and are interchangeable.
  • Individual fixtures have whole number Y.
  • For replacement parts, provide ID# and order #.

MARK LIGHTING S2WI Indirect Wall Light - fig 22

Mounting Hardware:
Mounting rails are attached to each fixture section. Unscrew the mounting rails from the fixture to install rails to the wall first.

Set Up Wall

MARK LIGHTING S2WI Indirect Wall Light - fig 18 At power feed locations:
Mount the J-box on the wall at distanced 5-13/16” from the start of run. The center line of J-box and luminaire run should align with each other.
MARK LIGHTING S2WI Indirect Wall Light - fig 19Secure mounting rails for the first fixture per pattern/row layout. Leave approximately 1-1/4” space from edge of the wall to mount the rail for the first section.
Note: Contractor should provide blocking behind wall to adequately support fixture weight.MARK LIGHTING S2WI Indirect Wall Light - fig
20 Level mounting rail to ensure proper mounting.

Opening Fixtures

MARK LIGHTING S2WI Indirect Wall Light - fig 16Grasp dust cover (if present) and pull it slowly out of the housing.     MARK LIGHTING S2WI Indirect Wall Light - fig
17Remove the wiring trays completely by removing screws from the side of the tray and disconnect the wiring harness from the tray.
NOTE: Do not discard removed screws. Save to secure the trays back in the fixture.

Mount Fixtures

**** All power connections should be installed according to local/national codes by a Certified Electrician.
Make wiring connections with wires from J-box. MARK LIGHTING S2WI Indirect Wall Light - fig 15

a. Slide top flange of mounting bracket underneath top flange of mounting rail.
b. Rotate fixture toward wall until bottom flange of the mounting bracket passes bottom flange of mounting rail.
c. While supporting fixture, rest bottom flange of the mounting bracket on bottom flange of mounting rail.
d. Rotate fixture up toward wall and secure at mounting points with #8 screw provided.

Join Sections

NOTE: Joining hardware parts provided in a separate red bag.
MARK LIGHTING S2WI Indirect Wall Light - fig 12Install (2) aligner keys onto secured section of the run. The bump on the aligner key should face the extrusion. Half of the aligner pin should be exposed to insert into the next section.   MARK LIGHTING S2WI Indirect
Wall Light - fig 13

a. Slide joining fixture while keeping aligner keys aligned to the slots from opposite fixture body.
b. Latch the hook (Detail “A”).
c. Install (2x) slider aligners by putting them into the appropriate position (Detail “B”).
NOTE: Pull wires into the next section before fully joining fixture together. From each quick connector provided on the intermediate ends of the fixture remove and discard the half (male or female) to which no wires are connected. Make electrical connections with quick connectors.

Close Fixture

MARK LIGHTING S2WI Indirect Wall Light - fig 9Insert reflectors into the housings.
MARK LIGHTING S2WI Indirect Wall Light - fig 10Secure reflectors with #8 screws.  MARK LIGHTING S2WI Indirect
Wall Light - fig 11

Gently push dust cover (if presented) and snap it in into the housing.
NOTE: Use two people when working with fixturesgreater than 4 feet.

Supplemental

MARK LIGHTING S2WI Indirect Wall Light - fig 6

Battery Pack/Test Switch (E10WLCP):
a. If battery pack option is selected (E10WLCP), then an un-switched normal hot is required for power and sensing.
b. Standard battery drop is on the right side of the section with the battery. See above diagram for location of test button.
MARK LIGHTING S2WI Indirect Wall Light - fig 7 For nLight option (NLIGHT):
Pull CAT5 cable through the knockout with the power cord and connect to the nLight device within the fixture.MARK LIGHTING S2WI Indirect Wall Light -
fig 8 nLight AIR NOTE:
Install antenna on coax cable.
MARK LIGHTING S2WI Indirect Wall Light - fig 3 Remote BGTD Mounting Option:
a. Suggested to mount in an accessible location for maintenance. To be installed in ceiling or to structure according to local and NEC code.
b. 6 foot flexible conduit is attached. The remote BGTD should be mounted within 6 feet of the J-box above the fixture.
MARK LIGHTING S2WI Indirect Wall Light - fig 4Dust Cover Removal (DC/DCF): To remove, lift dust cover.
MARK LIGHTING S2WI Indirect Wall Light - fig 5Wires used to power EMPACK.
NOTE: Cap the unused wire at the junction box.
Supplemental Wall Mounting Rails
MARK LIGHTING S2WI Indirect Wall Light - fig 1 Remove the cover where JB is using a flat head screw driver by inserting it in designated tabs. Pull wires and wire it in JB to power the fixture. Covers not in feed location should stay intact.         MARK LIGHTING S2WI Indirect
Wall Light - fig 2

Bend tabs on the end as shown above for begining of the run and end of run (first and last fixture). For intermediate fixtures remove tab by bending it and twisting as shown above on the right.
Check out helpful programs, tools, installation videos and more.
http://postsales.acuitybrands.com/qr/?sn=2562C210004322520

marklighting.com
I 800-705-SERV (7378)
[email protected]
© 2022
AcuityBrands Lighting, Inc.
All Rights Reserved.
We reserve the right to change design, materials and finish in any way
that will not alter installed appearance or reduce function and performance.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

MARK LIGHTING User Manuals

Related Manuals