MARK ARCHITECTURAL LIGHTING S4LS Slot 4 Direct Surface Pendant Light Instruction Manual

June 9, 2024
MARK ARCHITECTURAL LIGHTING

SLOT 2/4

SAFETY

Important Safety Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.

  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.

  • Installation and service of luminaires should be performed by a qualified licensed electrician.

  • Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended

  • It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.

  • DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit.
    Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.

  • Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.

  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection
    with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

|

WARNING RISK OF ELECTRIC SHOCK


✓ Disconnect or turn off power before installation or servicing.

✓ Verify that supply voltage is correct by comparing it with the luminaire label information.

✓ Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable

✓ All wiring connections should be capped with UL approved recognized wire
connectors.

|

WARNING RISK OF BURN


✓ Allow lamp/fixture to cool before handling. Do not touch  enclosure or light source.

✓ Do not exceed maximum wattage marked on luminaire label.

✓ Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

|

CAUTION RISK OF INJURY


✓ Wear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing maintenance.

✓ Avoid direct eye exposure to the light source while it is on.

|

CAUTION RISK OF INJURY


✓ Keep combustible and other materials that can burn, away from lamp/lens.

✓ Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.

|

CAUTION: RISK OF PRODUCT DAMAGE


✓ Never connect components under load.

✓Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.

✓ Controls for dimming, auto-sensing, or remote control of a luminaire that are not factory-wired to the luminaire must be checked for compatibility with the luminaire prior to installation. LED fixtures must be powered directly o ffa switched circuit.

✓ Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.

✓ Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.

✓Only use fixture in its intended location.

✓ LED products are Polarity Sensitive. Ensure proper Polarity before installation

✓ Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.

✓Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.

✓Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.

✓ Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings

✓ Always ensure that the electrical distribution system is up to NEC (and any applicable local code) requirements.

✓ Verify that power distribution system has proper grounding. Lack of proper earth ground can lead to fixture failure and may void warranty.

Choose either Part 15 OR Part 18 and move to Page 3 Installation Instructions under Delivery. Lithonia Outdoor will always use Part 15.
All luminaires that contain electronic devices that generate frequencies above 9kHz from any component within the luminaire comply with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference
  2. This device must accept any interference received, including interference that may cause undesired operation

This device complies with Part 18 of the FCC Rules but may cause interference with cordless and cell phones, radios, televisions, and other electronic devices. To correct the problem, move the device away from the luminaire or plug into a different outlet. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communications equipment operating between 0.45-30MHz.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

ABL LED General Warnings, Form No. 503.203

© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION

  • To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.

  • Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.

  • Installation and service should be performed by a qualified licensed electrician.

  • Maintenance should be performed by qualified person(s) familiar with the products’ construction and operation and any hazards involved. Regular
    maintenance programs are recommended.

  • DO NOT INSTALL DAMAGED PRODUCT! This product has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.

  • These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.

|

WARNING RISK OF ELECTRIC SHOCK


✓ Disconnect or turn off power before installation or servicing.

✓ Verify that supply voltage is correct by comparing it with the luminaire label information.

✓ Make all electrical and grounded connections in accordance National Electrical Code (NEC) and any applicable

✓ All wiring connections should be capped with UL approved recognized wire connectors. with the local code requirements.

|

CAUTION RISK OF INJURY


✓ Wear gloves and safety glasses at all times when removing  luminaire from carton, installing, servicing or performing maintenance.

✓ Avoid direct eye exposure to the light source while it is on.

|

WARNING RISK OF BURN


✓ Allow lamp/fixture to cool before handling. Do not touch enclosure or light source.

✓ Do not exceed maximum wattage marked on luminaire label.

✓ Follow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting locations/methods, replacement and recycling.

|

CAUTION RISK OF FIRE


✓ Keep combustible and other materials that can burn, away from lamp/lens.

✓ Do not operate in close proximity to persons, combustible  materials or substances affected by heat or drying

Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please
visit www.acuitybrands.com.

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.

ABL LED General Warnings, Form No. 503.203

© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

|

CAUTION: RISK OF PRODUCT DAMAGE


✓ Electrostatic Discharge (ESD): ESD can damage product(s). Personal grounding equipment must be worn during all installation or servicing of the unit.

✓ Do not touch individual electrical components as this can cause ESD and affect product Performance.

✓ Do not stretch or use cable sets that are to short or are of insufficient length.

✓ Do not tamper with contacts

✓ Do not modify the product.

✓ Do not change or alter internal wiring or installation circuitry

✓ Do not use product for anything other than its intended use

✓ If installing latching springs: ensure that the springs are fully engaged prior to moving to next connection.

✓ If installing wiring systems: Materials and component parts of a manufacturing wiring system as described in Article 604 of the National Electric Code and Underwriters Laboratories Standard for Safety #183 MUST BE installed.

Please see product specific installation instructions for additional warnings or any applicable FCC or other regulatory statements.

Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please
visit www.acuitybrands.com.

Our Brands

Indoor/Outdoor

Lithonia Lighting

Carandini
Holophane

RELOC

Light Concepts

Indoor Lighting
Gotham
Mark Architectural Lighting
Peerless
Renaissance Lighting
Winona Lighting

Outdoor Lighting
American Electric Lighting
Antique Street Lamps
Hydrel
Tersen

Controls

DARK TO LIGHT

LC&D

ROAM

Sensor Switch

Synergy

Daylighting

SunOptics

Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203

© 2021, 2010, 2016 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10

OVERVIEW – FIXTURE

  • .To be mounted to hard lid or sheetrock ceilings.
  • Do not join fixtures together on the floor

NOTE: Illustrations are used for reference only and can differ slightly from the actual lighting system installed. However, key components addressed in this information are represented as accurately as possible.

MOUNTING

INDIVIDUAL FIXTURE CONGIGRATIONS

INDIVIDUAL UNITS (MOUNTING)


LENGTH

| “A” O.A.L| “B-1” O.C.| “B-2” O.C.| “C” FROM END

2FT

| 2’-5/8| 2”| 1’-7”|

13/16”

3FT

| 3’-5/8| 2”| 2’-7”|

13/16”

4FT

| 4’-5/8| 2”| 3’-7”|

13/16”

5FT

| 5’-5/8| 2”| 4’-7”|

13/16”

6FT

| 6’-5/8| 2”| 5’-7”|

13/16”

7FT

| 7’-5/8| 2”| 6’-7”|

13/16”

8FT

| 8’-5/8| 2”| 7’-7”|

13/16”

RUN CONFIGURATIONS

RUN LAYOUT (MOUNTING)

LENGTH

| “A-1” O.A.L| “A-2” O.A.L.| “B” O.C|

“C” FROM END

4FT

| 4’-0 5/16”| 4’-0”| 3’-11”|

13/16”

5FT

| 5’-0 5/16”| 5’-0”| 4’-11”|

13/16”

6FT

| 6’-0 5/16”| 6’-0”| 5’-11”|

13/16”

7FT

| 7’-0 5/16””| 7’-0”| 6’-11”|

13/16”

8FT

| 8’-0 5/16| 8’-0”| 7’-11”|

13/16”

PREP FIXTURES AND PARTS

FIXTURES MUST BE INSTALLED IN ORDER AS SHOWN ON RECORD DRAWINGS.

  • Labels are located on the carton, on the fixture, and on the lens.
  • Each section is identified by and ID#
  • Section position starting with X.000 for the first fixture.
  • Same fixture configuration can carry identical ID# and are interchangeable.
  • Individual fixtures have whole number Y.
  • For replacement parts, provide ID# and order #.

OPENING FIXTURE

 Grasp inner tray by the lip and pull it slowly out of the housing.

Lower the inner tray gently until safety cables fully engage and part is supported.

MOUNT FIXTURE

All power connections should be installed according to local/national codes by a Certified Electrician.

Pull conduit from the ceiling to the first section and secure to the housing using a jam nut (Supplied by others).

Make wiring connections.

NOTE: Emergency feed uses the exact same feed kit and cord.

Secure individual or beginning section to the ceiling with 1/4”-20 lag bolts (by others) on both ends.

JOIN SECTION

(NOTE: Joining hardware parts provided in a separate yellow bag.)

  • Install (4) aligner pins onto the secured section of the run. Half of the aligner pin should be exposed to insert into the next section.
  • Slide unsecured joining section toward the secured section.

  • Insert joining bracket through slots at ends of the sections. Refer to Detail “A”.
  • Push joining bracket towards support bracket and align slot in joining bracket with cage nut.
  • Secure with #8 screw provided.

Make electrical connections with connectors provided.

CLOSE FIXTURE

  • Once all electrical connections are made, reinstall inner tray.
  • Gently push tray with lens inserted into the outer housing until engaged with the retaining clips.

NOTE: Use two people when working with fixtures greater than 4 feet. Be sure wires and safety cables are clear of pinch points.

SUPPLEMENTAL

If NLTAIR2 option is included:
Antenna will be shipped separately and will need to be attached to the coax connector.

Wallwash/Wall Graze (WW/WG) Direction:
Install the light so the clear side is closest to the wall to light.

Battery Pack/Test Switch (E10WLCP):

  • If battery pack option is selected (E10WLCP), then an un-switched normal hot is required for power and sensing.
  • Standard battery drop is on the right side of the section with the battery. See above diagram for location of test button.

CONTRACTOR’S RESOURCES

Check out helpful programs, tools, installation videos and more

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals