audio-technica AT-VMN95SH VM95 Series Shibata User Manual

June 9, 2024
Audio-Technica

audio technica LOGO Gpe Microsystems
Instruction Manual

AT-VMN95SH VM95 Series Shibata

G Series Interchangeable AC Plug Models

  1. Pull back tab and hold.
  2. Mate round corner of plug to round corner of receptacle.
  3. Insert plug into adapter receptacle head-first until it sits completely inside, then release tab to lock in place.

audio technica AT VMN95SH VM95 Series Shibata - FIGURE
2

CAUTION: ELECTRIC SHOCK
DO NOT INSERT PLUG ALONE TO ELECTRICAL OUTLET.

audio technica AT VMN95SH VM95 Series Shibata - FIGURE
3All plugs may not be included.
©Gpe Microsystems Corp. D1O1 G

AT-VMN95SH
User Manual
Replacement stylus

audio technica AT VMN95SH VM95 Series Shibata - FIGURE
1

Replacing the stylus

  1. Remove the replacement stylus by pulling in the direction of the arrow without touching the cantilever, stylus tip, and magnets. A
  2. Install a new replacement stylus onto the cartridge body. B
    Lifetime of the replacement stylus is approx. 800 hours.

Specifications

Tracking force: 1.8 to 2.2 g {2.0 g standard)
Stylus: Nude Shibata
Cartridge {sold separately): AT-VM95SH

60th ANNIVERSARY
Belt-Drive Turntable
Quick Start Guide
AT-LP2022 

User Manual (Online Manual)
https://www.audio-technica.co.jp/document/AT-LP2022/Default.html

https://www.audio-technica.co.jp/document/AT-LP2022/Default.html

Contents

audio technica AT VMN95SH VM95 Series Shibata -
Contents

Preparation

Use the included gloves to avoid fingerprints on the turntable

  1. With the turntable turned off, set the platter.audio technica AT VMN95SH VM95 Series Shibata - Preparation 1

  2. Attach the drive belt to the motor pulley.

  3. Level the turntable.audio technica AT VMN95SH VM95 Series Shibata - Preparation 3

  4. Insert the headshell into the tonearm, and remove the cartridge’s protector.

  5. Attach the counterweight to the back of the tonearm, and slowly turn it counterclockwise (to the left).audio technica AT VMN95SH VM95 Series Shibata - Preparation 5

  6. Unlatch the clamp.

  7. Turn the counterweight to adjust the tonearm’s balance so that the tonearm is level when you release the headshell.audio technica AT VMN95SH VM95 Series Shibata - Preparation 7

  8. Set the tracking force gauge ring to the “O” position.
    After that, turn the counterweight and the tracking force gauge ring together counterclockwise (to the left) to the “2” position.audio technica AT VMN95SH
VM95 Series Shibata - Preparation 8

  9. Set the anti-skate control dial to “2”, the same value as the tracking force value.audio technica AT VMN95SH VM95 Series Shibata - Preparation 9

Connection

Connect the turntable to the PHONO input of a phono equalizer or an amplifier with a built-in phono equalizer.

audio technica AT VMN95SH VM95 Series Shibata -
Connection

Play

  1. Remove the cartridge’s protector.audio technica AT VMN95SH VM95 Series Shibata - Play 1
  2. Turn the turntable on, place the record, and use the control knob to select the speed.audio technica AT VMN95SH VM95 Series Shibata - Play 2
  3. Raise the tonearm by lifting the tonearm lift control lever to the UP position.audio technica AT VMN95SH VM95 Series Shibata - Play 3
  4. Position the tonearm over the desired location (groove) on the record.audio technica AT VMN95SH VM95 Series Shibata - Play 4
  5. Lower the tonearm by moving the tonearm lift control lever to the DOWN position.audio technica AT VMN95SH VM95 Series Shibata - Play 5

Stop

  1. Lower the volume of the connected device (amplifier, etc.) .
  2. Raise the tonearm by lifting the tonearm lift control lever to the UP position.audio technica AT VMN95SH VM95 Series Shibata - Stop 2
  3. Return the tonearm to the tonearm rest.
  4. Lower the tonearm by moving the tonearm lift control lever to the DOWN position and fix it with the clamp.audio technica AT VMN95SH VM95 Series Shibata - Stop 4
  5. Turn the control knob to the “STOP” position.
  6. Attach the cartridge’s protector.audio technica AT VMN95SH VM95 Series Shibata - Stop 6
  7. Turn the turntable off.audio technica AT VMN95SH VM95 Series Shibata - Stop 7

Replacing the stylus

A replacement stylus (AT-VMN95SH CL) is included with the product.

  1. With the turntable turned off and the AC adapter unplugged from the outlet, release the headshell from the tonearm.audio technica AT VMN95SH VM95 Series Shibata - Replacing the stylus 1
  2. After removing the cartridge’s protector, remove the stylus by pulling in the direction of the arrow without touching the cantilever, stylus tip, and magnets.
  3. Mount the new replacement stylus to the cartridge.audio technica AT VMN95SH VM95 Series Shibata - Replacing the stylus 3
  4. Mount the headshell onto the tonearm.audio technica AT VMN95SH VM95 Series Shibata - Replacing the stylus 4
  5. Adjust the tonearm balance and tracking force.

Cleaning

After turning the turntable off and unplugging the AC adapter from the outlet, clean the turntable as necessary.
For details about turntable and cartridge care accessories, visit https://www.audio-technica.com.
Stylus

  1. audio technica AT VMN95SH VM95 Series Shibata - Stylus

Record

audio technica AT VMN95SH VM95 Series Shibata - Record

Audio-Technica Corporation
2-46-1 Nishi-naruse, Machida, Tokyo 194-8666, Japan
www.audio-technica.com
©2022 Audio-Technica Corporation
Global Support Contact: www.at-globalsupport.com
162502540-01-01
ver 1 2022.06.15

60th ANNIVERSARY
Caution Guide
AT-LP2022

Caution Guide
Belt-Drive Turntable

Thank you for purchasing this Audio-Technica product.
Before using the product. read through this caution guide to ensure that you will use the product correctly Please keep this manual for future reference.
■ Safety precautions
Although this product was designed to be used safely, failing to use it correctly may result in an accident. To ensure safety, observe all warnings and cautions while using the product.

Important information

Warning:
To prevent fire or shock hazard, do not expose this apparatus to rain or moisture.
Caution:

  • Do not expose this apparatus to drips or splashes.
  • To avoid electric shock, do not open the cabinet.
  • Refer servicing to qualified personnel only.
  • Do not expose this apparatus to excessive heat such as sunshine, fire or the like.
  • Do not subject this apparatus to strong impact.
  • This apparatus should be located close enough to the AC outlet so that you can easily grasp the AC adapter at any time.
  • In case of emergency, disconnect the AC adapter quickly.
  • Do not place any obJects filled with liquids, such as vases, on this apparatus.
  • To prevent fire, do not place any naked flame sources (such as lighted cand les) on this apparatus.
  • Do not install this apparatus in a confined space such as a bookcase or similar unit.
  • Install this apparatus only in the place where ventilation Is good.
  • The rating label is put on the bottom of this apparatus.

■ For customers in the USA
FCC Notice
Warning:
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Caution:
You are cautioned that any changes or modifications not expressly approved in this manual could void your authority to operate this equipment.
Note This equipment has been tested and found to comply with the l1m1ts for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user Is encouraged to try to correct the interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to which the receiver Is connected.
– Consult the dealer or an experienced radiorrv technician for help

Contact:
Responsible Company: Audio-Technica US., Inc.
Address: 1221 Commerce Drive, Stow, Ohio 44224, USA
Tel: 330-686-2600
■ For customers in Canada
ISED statement:
CAN ICES 003(B)/NMB-003(B)

Audio-Technica Corporation
2-46-1 Nishi-naruse, Machida, Tokyo 194-8666, Japan
www.audio-technica.com
©2022 Audio-Technica Corporation
Global Support Contact : www.at-globalsupport.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Audio-Technica User Manuals

Related Manuals