SUPER VAC AF124 Ventilation Fans Saws and Accessory User Guide
- June 9, 2024
- SUPER VAC
Table of Contents
- SUPER VAC AF124 Ventilation Fans Saws and Accessory
- Breakage or Damage During Shipment
- General Description and Specifications
- Product Safety Precautions
- Before Operating Ventilator
- Operation
- Maintenance and Repair
- Parts List
- Exploded View
- Warranty
- Contact Information
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SUPER VAC AF124 Ventilation Fans Saws and Accessory
Breakage or Damage During Shipment
The transportation company is fully responsible for all shipping damage and
will resolve problems promptly if you handle it correctly. Please read these
instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your
transportation agent at once and have them make a description on the freight
or express bill describing the damage and the number of pieces. Then write us
and we will send you the original bill of lading. Get a claim blank from the
express or truck company. Fill the claim form out. Attach the claim blank to
the original bill of lading together with a copy of our invoice. Attach a memo
on which you show the value of the damaged goods. Mail or hand these papers to
your local transportation agent. They will process your claim with reasonable
promptness.
Please note, we cannot and will not enter claims for damages. If we filed
claim here, it would be sent to your local freight agent for verification and
investigation. This time can be saved by your filing the claim directly. Every
consignee is on the ground floor and in contact with the local agent who
inspects the damaged goods, and thus, each claim can be given individual
attention.
Since our goods are packed to comply with the regulations of all railroad,
truck, and express companies, we cannot allow deduction from any invoice
because of any damage, however, be sure to file your claim promptly. Our goods
are sold F.O.B. factory. We take receipt from the transportation company
certifying that the goods were delivered to them in good order, and our
responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments, and
in no case will the customer be out any expense if they follow the above
instructions.
Be sure to keep all damaged goods subject to examination of the truck or
express company inspector, who may call on you some time later. These damaged
goods, of course, will belong to them, and they will inform you what to do
with them. If you dispose of these damaged goods, your claim may not be paid.
General Description and Specifications
Super Vac ventilators are specifically designed to provide a convenient and portable source of fresh air. Specifications1
Specifications are subject to change without notification. Refer to model
decal affixed to ventilator to determine actual specifications.
This ventilator is designed for high powered air movement. Super Vac’s
patented propeller produces a greater intake of air and eliminates turbulence
at the tips. The high velocity screw action sweeps air back over the motor,
enabling it to run cooler. The patented 4-Blade propeller is cast from
aluminum alloy. Each blade is dynamically balanced for high efficiency and
long life.
All Super Vac ventilators are designed to accept optional spiral duct and
adapters. Placing adapter and ducts on the output side provides positive
pressure ventilation. Place adapter and duct on the input side for negative
pressure ventilation.
The square housing design gives the unit added strength and stability. Handles
on each corner makes the ventilator easy to hang on windows, doorways or
ladders.
Product Safety Precautions
- Do not use the ventilator for purposes other than its’ intended use.
- Wear eye and ear protection when operating the ventilator.
- Never operate ventilator while fatigued.
- Do not disassemble or modify the ventilator in any way. Doing so may lead to mechanical failure or personal injury.
- Do not wear loose clothing that could become entangled in the operating ventilator.
- Do not operate ventilator without proper inlet or outlet guards in place. If guards are missing or damaged, contact factory for replacements.
- Do not place fingers or other foreign objects through inlet or outlet guards. Should a foreign object enter the ventilator, immediately disconnect power source. Be certain all mechanical motion has stopped before removing foreign object.
- Air motor is designed to be driven by compressed air and under no circumstances is to be driven with any other gases.
- Always disconnect air supply before servicing.
- Do not exceed the maximum operating air pressure of 100 PSI.
- Do not place or operate ventilator on unsteady tables, slanted surfaces or other unstable surfaces.
- Operating temperature under normal conditions up to 250°F (121°C). While in hazardous locations, operating temperature up to 104°F (40°C).
Before Operating Ventilator
- Always operate this ventilator from a proper compressed air source. Never use combustible gases to power the motor.
- A complete inspection of the ventilator should be made prior to operation.
- Check all threaded fasteners for proper tightness.
- Drain any accumulated moisture from the air filter.
- Check automatic lubricator oil level. Replenish oil as necessary.
- Inspect inlet and outlet guards for damage or missing pieces. Replace damaged or missing guards before operating ventilator.
Operation
Check ventilator inlet and outlet guards for obstructions. Check and remove
from immediate surrounding area any
objects that could be drawn into the ventilator intake.
Place ventilator in desired location before connecting to air supply.
Extend and place any flexible duct as required. Use caution not to direct
toxic fumes into confined spaces with the ventilator. Please refer to the
Super Vac Training Manual for Smoke Ventilation for comprehensive instruction
on effective ventilation practices.
Connect air supply line to ventilator. Turn ball valve lever to the open
position to begin ventilation. Adjust blade speed with air regulator.
To stop ventilation, move ball valve lever to closed position, disconnect air
supply line.
Maintenance and Repair
Maintenance should only be performed by experienced and trained personnel.
Be sure the ventilator is disconnected from the air supply source before
performing any maintenance or repair.
The motor requires lubrication within the air supply at the rate of 1 drop of
oil for every 50 CFM of air going through. Lubrication is necessary for all
internal moving parts and rust prevention.
Drain any accumulated moisture from the air filter at regular intervals.
The ventilator blade should be specially checked for build-up of material or
dirt which may cause an imbalance. Excessive imbalance can lead to accelerated
wear on motor bearings and vibration. Remove ventilator guards. Clean blade
and inside housing with mild detergent and water. Do not use abrasives, sharp
instruments or caustic solvents that may scratch or damage the aluminum alloy
blade.
Intake and exhaust guards are not interchangeable. When replacing guards after
cleaning, position them with the rings to the outside with the row of spot
welds holding the rings on the bottom.
Parts List
MODEL | HP | RPM |
---|---|---|
AF124i | 0.93 |
2000
1 | 012-13842 | 1 | GUARD 16” STD. FRONT |
---|---|---|---|
2 | 032-10711 | 8 | 10-24 X 1/2″ PHIL PH MS ZINC |
3 | 032-10713 | 8 | 10-24 NYLOK SELF LOCK NUT ZINC |
4 | 032-10759 | 1 | 1/4 – 20 LEFT HAND SCREW ZINC |
5 | 032-10755 | 1 | 1/4” FENDER WASHER ZINC |
6 | 032-10761 | 2 | 5/16 – 18 x 1/2” ALLEN SET SCREW |
7 | 003-10041 | 1 | BLADE 16” FOUR BLADE TENZALOY |
8 | 034-11010 | 3 | 1/4-20 X 1/2” SOCKET CS SS |
9 | 1 | MOTOR MOUNT AF124i | |
10 | 008-10193 | 1 | MOTOR SHAFT KEY 3/16” X 1” |
11 | 009-10222 | 1 | AIR MOTOR #4Z231 16” PNEU. FAN |
12 | 032-10769 | 4 | 5/16-18 X 1” HEX CS USS ZINC |
13 | 032-10786 | 4 | 5/16 FLAT WASHER ZINC |
14 | 032-10790 | 4 | 5/16-18 NYLOK HEX NUT ZINC |
15 | 024-10527 | 4 | FEET #1409-W RECTANGULAR |
16 | 032-10698 | 8 | 8-32 X 1/2” PHIL PH MS ZINC |
17 | 032-10695 | 8 | 8-32 HEX NUT ZINC |
18 | 018-10381 | 1 | HOUSING 16” STEEL – PAINTED |
19 | 012-13843 | 1 | GUARD 16” STD. REAR |
20 | BONNET AF124i | ||
21 | 032-10725 | 4 | 1/4-20 X 5/8” PHIL RH MS ZINC |
22 | 032-10750 | 4 | 1/4-20 NYLOK HEX NUT ZINC |
23 | 056-12384 | 1 | PLUG 1/2” MP-500 |
24 | 056-12386 | 1 | PLUG 7/8” DP-875 |
25 | 009-10228 | 1 | CLAW COUPLING #AM-8 |
26 | 044-11807 | 1 | 3/4” X 5” NIPPLE |
27 | 009-11892 | 1 | VALVE PARKER 3/4 inch #V500P-12 BALL |
28 | 009-10225 | 1 | FILTER AIR #6ZC32 |
29 | 009-11747 | 1 | BRAKE LINE 5/8” X 15” |
30 | 009-10226 | 1 | GUAGE AIR #4X513 BOTTOM STEM |
31 | 009-10223 | 1 | REGULATOR AIR #6ZC31 |
32 | 044-11797 | 2 | 3/4” CLOSE NIPPLE |
33 | 009-10224 | 1 | LUBRICATOR AIR #6ZC30 |
34 | 009-10234 | 4 | FITTING 3/4” X 90 DEG. BLK. STREET EL |
35 | 009-10230 | 3 | WEATHERHEAD #1468-10-12 5/8 X 3/4” MPT |
36 | 009-11747 | 1 | BRAKE LINE 5/8” X 13 1/2” |
37 | 009-10233 | 1 | WEATHERHEAD #3400-6 5/8 X 3/8 MPT |
38 | 066-14672 | 1 | BRASS FITTING 3/8” 45 DEGREE STREET EL |
39 | 009-14671 | 1 | BRASS FITTING 3/8” 90 DEGREE STREET EL |
40 | 009-12977 | 1 | MUFFLER FOR WWG 4Z231 AIR MOTOR |
41 | 025-10548 | 1 | DECAL – CAUTION GUARDS REMOVED |
42 | 025-13287 | 1 | DECAL – ATTENTION LUBRICATOR |
43 | 1 | DECAL – AF124i CSV | |
44 | 025-10548 | 1 | DECAL – EXHAUST ARROW |
45 | |||
46 | |||
47 | |||
48 | |||
49 | |||
50 | |||
51 | |||
52 | |||
53 | |||
Exploded View
Warranty
Limited Warranty Five Years
Super Vacuum Manufacturing Company Inc. warrants that the equipment is free
from defects in materials and workmanship when used and operated for a period
of five years. The responsibility of Super Vacuum Manufacturing Company Inc.
under this limited warranty is limited to the repair and replacement of any
parts which are found defective and which are returned to Super Vacuum
Manufacturing Company Inc. at 3842 Redman Drive, Fort Collins, Colorado 80524
with transportation charges prepaid (C.O.D. shipments will not be accepted).
Prior to returning defective parts to SUPER VACUUM MANUFACTURING COMPANY INC,
the original purchaser shall make a claim in writing to SUPER VACUUM
MANUFACTURING COMPANY INC at the above address indicating the model number and
type of defect. No parts or equipment will be received by SUPER VACUUM
MANUFACTURING COMPANY INC for repair or replacement under this warranty
without specific written authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of
any type or cause are not covered by this warranty.
All equipment manufactured by us is pre-run and tested before leaving our
plant, and is shipped in good working order and condition. We therefore extend
to the original purchasers the following Limited Warranty for the period of
five years from the original date of purchase:
- This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernable when the equipment is returned to us for inspection.
- On all component parts not manufactured by SUPER VACUUM MANUFACTURING COMPANY INC, their warranty is to the extent that the manufacturer of such component warrants them to SUPER VACUUM MANUFACTURING COMPANY INC, if at all. Look in your local business phone directory for the nearest repair station for the brand of parts you have or write to us for the address.
- If equipment received is found to have been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
- Any service other than our Authorized Service voids this warranty.
- This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTIBILITY or FITNESS for a particular purpose.
Contact Information
For parts or service information, contact:
Super Vacuum Manufacturing Company, Inc. 3842 Redman Drive
Fort Collins CO 80524
- Phone: 1-800-525-5224, 970-297-7100
- FAX: 970-297-7099
- Internet: www.supervac.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>