SUPER VAC V20-EV Positive Pressure Ventilator User Guide
- March 18, 2024
- SUPER VAC
Table of Contents
READ THIS FIRST
VENTILATOR USER GUIDE
MODEL V20-EV
V20-EV Positive Pressure Ventilator
DANGER
PERSONAL RESPONSIBILITY CODE
The member companies of FEMSA that provide emergency response equipment and
services want responders to know and understand the following:
- Firefighting and Emergency Response are inherently dangerous activities requiring proper training in their hazards and the use of extreme caution at all times.
- It is your responsibility to read and understand any user’s instructions, including purpose and limitations, provided with any piece of equipment you may be called upon to use.
- It is your responsibility to know that you have been properly trained in Firefighting and/or Emergency Response and in the use, precautions, and care of any equipment you may be called upon to use.
- It is your responsibility to be in proper physical condition and to maintain the personal skill level required to operate any equipment you may be called upon to use.
- It is your responsibility to know that your equipment is in operable condition and has been maintained in accordance with the manufacturer’s instructions.
- Failure to follow these guidelines may result in death, burns or other severe injury.
Fire and Emergency Manufacturers and Services Association, Inc.
PO. Box 147, Lynnfield, MA 01940 www.FEMSA.org
Copyright 2006 FEMSA. All Rights Reserved
USER GUIDE
This manual covers the description, cautions, operation, and maintenance of
the Super Vac V20-EV.
Read this manual before operating the ventilator.
Save this guide for future reference.
Breakage or Damage During Shipment
The transportation company is fully responsible for all shipping damage and
will resolve problems promptly if you handle it correctly. Please read these
instructions carefully.
Examine the contents of all shipping cases. If you find any damage, call your
transportation agent at once and have them make a description on the freight
or express bill describing the damage and the number of pieces. Then write us
and we will send you the original bill of lading. Get a claim blank from the
express or truck company. Fill the claim form out. Attach the claim blank to
the original bill of lading together with a copy of our invoice. Attach a memo
on which you show the value of the damaged goods. Mail or hand these papers to
your local transportation agent. They will process your claim with reasonable
promptness.
Please note, we cannot and will not enter claims for damages. If we filed
claim here, it would be sent to your local freight agent for verification and
investigation. This time can be saved by your filing the claim directly. Every
consignee is on the ground floor and in contact with the local agent who
inspects the damaged goods, and thus, each claim can be given individual
attention.
Since our goods are packed to comply with the regulations of all railroad,
truck, and express companies, we cannot allow deduction from any invoice
because of any damage, however, be sure to file your claim promptly. Our goods
are sold F.O.B.
factory. We take receipt from the transportation company certifying that the
goods were delivered to them in good order, and our responsibility ceases.
It is seldom that any breakage or damage occurs in any of our shipments, and
in no case will the customer be out any expense if they follow the above
instructions.
Be sure to keep all damaged goods subject to examination of the truck or
express company inspector, who may call on you some time later. These damaged
goods, of course, will belong to them, and they will inform you what to do
with them. If you dispose of these damaged goods, your claim may not be paid.
General Description and Specifications
Super Vac ventilators are specifically designed to provide a convenient and portable source of air. Super Vac positive pressure ventilators are tested to AMCA PPV Standard 240-95, for use in extreme conditions.
Model # | RPM | Voltage | Motor | HxWxD | Weight |
---|---|---|---|---|---|
V20-EV | 2400 | 115V AC | 1.5 Hp Variable Speed | 26″ x 25″ x 23″ | 77 lbs |
Specifications are subject to change without notification. Refer to model
decal affixed to ventilator to determine actual specifications.
This ventilator is designed for high powered air movement. Super Vac’s
propeller produces a greater intake of air and eliminates turbulence at the
tips. Each blade is dynamically balanced for high efficiency and long life.
Product Safety Precautions
- Do not use the ventilator for purposes other than its’ intended use.
- Wear eye and ear protection when operating the ventilator.
- Never operate ventilator while fatigued.
- Do not disassemble or modify the ventilator in any way. Doing so may lead to mechanical failure or personal injury.
- Do not wear loose clothing that could become entangled in the operating ventilator.
- Never permit anyone to operate ventilator without proper instruction.
- Do not operate ventilator without proper inlet or outlet guards in place. If guards are missing or damaged, contact factory for replacements.
- Do not place fingers or other foreign objects through inlet or outlet guards. Should a foreign object enter the ventilator, immediately stop motor. Be certain all mechanical motion has stopped. Do not use with any power voltage other than the indicated voltage.
- Never handle energized power cords with wet hands.
- Do not place or operate ventilator on unsteady tables, slanted surfaces or other unstable surfaces. Never use this ventilator in any explosive environment.
- Never let extension cords or plug connection lay in water. Locate the ventilator so that it cannot fall into water inadverntly.
Before Operating Ventilator
- Always operate this ventilator from a proper AC power source supplied through a ground fault interrupter receptacle.
- Test receptacle for ground fault before plugging in the ventilator power cord.
- Never use power cords with frayed, cut, or brittle insulation.
- A complete inspection of the ventilator should be made prior to operation.
- Inspect power cord plug for sound connections to the ground fault interrupter circuit.
- Check all threaded fasteners for proper tightness.
- Inspect inlet and outlet guards for damage or missing pieces. Replace damaged or missing guards before operating ventilator.
Operation
Check ventilator inlet and outlet guards for obstructions. Check and remove
from immediate surrounding area any objects that could be drawn into the
ventilator intake.
Place ventilator in desired location before connecting battery pack. Use
caution not to direct toxic fumes into confined spaces with the ventilator.
Please refer to the Super Vac Training Manual for Smoke Ventilation for
comprehensive instruction on effective ventilation practices.
Insert power cord plug into 115V AC power receptacle to begin ventilation.
To stop ventilation remove power cord plug from AC power receptacle.
Motors are equipped with thermal overload protection. When internal motor
temperature exceeds design limits, the motor will automatically shut off.
Motor will automatically restart when it cools sufficiently after overheating.
Remove power cord plug from AC receptacle before examining or working on a
motor which has stopped because of overheating. Thermal overload protection
sensitivity increases with frequency. Take preventative steps to correct cause
of overheating to assure long motor life. Most overheating problems are
associated with the use of portable power generators as the ventilator power
supply.
Maintenance and Repair
Maintenance should only be performed by experienced and trained personnel.
Be sure the ventilator is disconnected from the power source before performing
any maintenance or repair. The motor is of heavy duty ball bearing
construction. The unit is completely sealed and requires no lubrication for
the life of the motor.
The ventilator blade should be specially checked for build-up of material or
dirt which may cause an imbalance. Excessive imbalance can lead to accelerated
wear on motor bearings and vibration. Remove ventilator guards. Clean blade
and inside housing with mild detergent and water. Do not use abrasives, sharp
instruments or caustic solvents that may scratch or damage the aluminum alloy
blade.
Intake and exhaust guards are not interchangeable. When replacing guards after
cleaning, position them with the rings to the outside with the row of spot
welds holding the rings on the bottom.
Extension Cords
Do not use reeled or coiled cable. Reeled or coiled cable can produce a counter EMF (electromotive force). The counter EMF can reduce the current carrying capability of an extension cord. This counter EMF will result in a voltage drop within the motor instigating a thermal overload condition. Power supply must handle wattage requirements. When conditions require the use of reeled cable, unreel all cable and place on the ground in very loose overlapping non-uniform coils.
**Units*** | **Watts *** | Minimum Wire Gauge | Maximum Cable Length |
---|---|---|---|
1 | 2000 | 14 | 150 ft |
2 | 4000 | 12 | 250 ft |
3 | 6000 | 10 | 350 ft |
- Multiple units powered by one extension cord
** Minimum running wattage for multiple units. Startup amerage draw is much higher.
Warranty
Super Vacuum Manufacturing Company warrants that the equipment is free from
defects in materials and workmanship when used and operated for a period of
five years. The responsibility of Super Vacuum Manufacturing Company under
this limited warranty is limited to the repair and replacement of any parts
which are found defective and which are returned to Super Vacuum Manufacturing
Company at 3842 Redman Dr, Fort Collins, CO 80524 with transportation charges
prepaid (C.O.D. shipments will not be accepted).
Prior to returning defective parts to SUPER VACUUM MANUFACTURING COMPANY, the
original purchaser shall make a claim in writing to SUPER VACUUM MANUFACTURING
COMPANY at the above address indicating the model number and type of defect.
No parts or equipment will be received by SUPER VACUUM MANUFACTURING COMPANY
for repair or replacement under this warranty without specific written
authority from it in advance.
Any parts damaged by improper installation, overloading, abuse or accident of
any type or cause are not covered by this warranty.
All equipment manufactured by us is pre-run and tested before leaving our
plant, and is shipped in good working order and condition. We therefore extend
to the original purchasers the following Limited Warranty for the period of
five years from the original date of purchase:
- This warranty does not apply to defects caused by accident, misuse, neglect, or wear and tear, nor can we be held responsible for incidental and consequential expense and loss, nor does this warranty apply to equipment where alterations have been executed without our knowledge or consent. These conditions are readily discernible when the equipment is returned to us for inspection.
- On all component parts not manufactured by SUPER VACUUM MANUFACTURING COMPANY, their warranty is to the extent that the manufacturer of such component warrants them to SUPER VACUUM MANUFACTURING COMPANY, if at all. Look in your local business phone directory for the nearest repair station for the brand of parts you have or write to us for the address.
- If equipment received is found to have been damaged in transit, a claim should be made against the carrier within three days, as we assume no responsibility for such damage.
- Any service other than our Authorized Service voids this warranty.
- This warranty is in lieu of and is intended to exclude all other warranties, express or implied, oral or written, including any warranties of MERCHANTABILITY or FITNESS for a particular purpose.
Contact Information
For parts or service information, contact:
Super Vacuum Manufacturing Company, Inc.
3842 Redman Dr.
Fort Collins, CO 80524
Phone: 800-525-5224
970-297-7100
Fax: 970-297-7099
Email : info@supervac.com
Internet: www.supervac.com
Parts List
1 | 019-20304 | 1 | FRAME, RND 1.25 OD ALUM. VALOR, V-20 |
---|---|---|---|
2 | 019-20306 | 1 | HANDLE, V-20 |
3 | 019-20217 | 2 | PLATE, ADJUSTMENT LOCK,V-18, V-20 |
4 | 1420312 | 1 | ASSEMBLY,WHEEL,ADJUSTMENT,V-20 |
5 | 1420311 | 1 | ADJUSTMENT, FOOT LEVER, V-20 |
6 | 019-20239 | 3 | BLOCK, PEDAL AXLE MOUNT |
7 | 019-20240 | 2 | LEVER, PIVOT LOCK |
8 | 1420241 | 2 | ROD, PULL, FOOT LEVER |
9 | STD HARDWARE-IEW-11 | 2 | WASHER,LOCK,18-8SS,INTERNAL,3/8in |
10 | STD HARDWARE W27 | 2 | WASHER,FLAT,USS, 3/8″, SS |
11 | STD HARDWARE-BHSH-83b | 1 | SCREW,BHSH,3/8-16×2-1/2,SS |
12 | STD HARDWARE-ANUT-06 | 2 | NUT,ACORN, 3/8-16 UNC, SS |
13 | STD HARDWARE-59 | 8 | SCRBV,PHP,10-24 UNCx0.75 |
14 | 034-11033 | 4 | NUT,NYLOCK, 1/4-20 UNC,SS |
15 | 034-11116 | 2 | NUT,NYLOCK,THIN, 1/4-20 UNC,SS |
16 | 034-11057 | 10 | NUT,NYLOCK, 5/16-18 UNC,SS |
17 | STD HARDWARE-FHMS-157 | 2 | SCREW,FHPMS,5/16-18 UNC x 3/4 in,SS |
18 | STD HARDWARE-HHCS-236 | 4 | SCREW,HH,5/16-24×1-3/4,SS |
19 | STD HARDWARE W24 | 8 | WASHER,FLAT,USS, 5/16″, SS |
20 | 017-14999 | 1 | BUSHING,1-1/4 OD,1 INCH,718, V-20 |
21 | 008-10174 | 1 | SPACER, MOTOR, VR3, V20 |
22 | STD HARDWARE-57 | 14 | SCREW,PHP,10-24 UNCx0.5 |
23 | 018-10436 | 1 | SHROUD, 20″ W/GUARD-PAINTED |
24 | 012-15394 | 1 | STREAMSHAPER GUARD, FRONT, 20″ PPV FAN |
25 | 021.10521 | 1 | MOTOR 1.5 HP, VARIABLE SPEED, RAE |
26 | 019-10478 | 1 | PLATE,ADAPTER,ELECTRIC 720 |
27 | 003-10047 | 1 | 20″ FAN BLADE |
28 | 008-10193 | 1 | KEYSTOCK,SHAFT,BLADE,718, V-18 |
29 | 008-10187 | 1 | BUSHING,BLADE, MAUREY HQ 3/4 |
30 | STD HARDWARE-HHCS-08 | 2 | SCREW,HH,1/4-20×1-1/4,SS |
31 | STD HARDWARE LW35 | 2 | WASHER,LOCK,SPRING,REGULAR, 1/4″, SS |
32 | STD HARDWARE-HHCS-30 | 1 | SCREW,HH,5/16-18×3/4,SS |
33 | STD HARDWARE LW39 | 5 | WASHER,LOCK,SPRING,REGULAR, 5/16″, SS |
34 | STD HARDWARE W25 | 1 | WASHER,FLAT,FENDER, 5/16″, SS |
35 | STD HARDWARE-HHCS-35 | 4 | SCREW,HH,5/16-18×1-1/2,SS |
36 | 024-13473 | 4 | FEET RUBBER CONE SHAPE VBM-4002 |
37 | 008-13374 | 2 | WHEEL, 8 INCH |
38 | STD HARDWARE-HHCS-316 | 2 | SCREW,HH,1/2-20×3-1/2,SS |
39 | STD HARDWARE W34 | 6 | WASHER,FLAT,USS, 1/2″, SS |
40 | STD HARDWARE-NN16 | 2 | NUT,NYLOCK, 1/2-13 UNC,SS |
41 | 005-10255 | 1 | T-HANDLE, PLUNGER, VALOR |
42 | 034-10125 | 2 | ROLL PIN, 5/32 X 1 1/4 SS, VALOR |
43 | 005-10256 | 4 | PLUG, 1.25, TUBE END ROUND, VALOR |
44 | 024-15161 | 4 | PNEUMATIC MOUNTS 16340 ZN, VALOR FANS |
45 | 024-15160 | 2 | GAS SPRING, 12.00 IN, 40 LB, VALOR SERIES |
46 | 024-13284 | 2 | SPRING, COMPRESSION, TILT LEVER |
47 | STD HARDWARE-111 | 1 | SCREW,BHSH,3/8-16×3-1/2,SS |
48 | 034-10981 | 8 | NUT,NYLOCK, 10-24 UNC,SS |
49 | STD HARDWARE-HHCS-11 | 2 | SCREW,HH,1/4-20×2,SS |
50 | STD HARDWARE-HI-ICS-234 | 2 | SCREW,HH,5/16-24×1-1/4,SS |
Exploded View
V20-EV PPV User Guide
Revised 11-2023
Documents / Resources
|
SUPER VAC V20-EV Positive Pressure
Ventilator
[pdf] User Guide
V20-EV Positive Pressure Ventilator, V20-EV, Positive Pressure Ventilator,
Pressure Ventilator, Ventilator
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>