COSTWAY 63407219 Electric Car Cooler Refrigerator User Manual
- June 9, 2024
- COSTWAY
Table of Contents
63407219 Electric Car Cooler Refrigerator User Manual
63407219 Electric Car Cooler Refrigerator
Accessories available separately:
Protective Transit Bag
AC110V -240Vto DC 12 V Power Adaptor
Please read this manual carefully before using your unit.
Section | Page |
---|---|
Key Product Features | 1 |
Safety Instructions | 1 |
Notes on using the product | 2 |
Operation | 2-3 |
Cleaning and Maintenance | 4 |
Troubleshooting | 4-5 |
Error Protection Function | 5 |
Technical Data | 6 |
Packing List | 7 |
Key Product Features:
- The most reliable portable cooling system in the world.
- Electronics, high efficiency, low energy consumption.
- Multi-voltage system DC (12 and 24 Volt )
- Adjustable battery protection helps protect your battery (DC only).
Safety Instructions
- Warning: Do not use your unit if any cabling is damaged, frayed or there is exposed wiring.
- Warning: Do not attempt or continue to operate your unit if it is wet.
- When using the refrigerator in the vehicle, please make sure the circuit being used is fused, recommended size for DC 12 Volt is 15 Amp, DC 24 Volt is 7.5 Amp.
- Make sure the voltage is within the correct range for socket and cable being used. The technical data label on the side of the unit shows the voltage ranges.
- Do not place any electrical devices inside the refrigerator as they may be damaged.
Notes on using the product
-
* Your unit requires good ventilation, especially around the back of the refrigerator; allow a gap of at least 4″ around all sides.
- Do not allow a large amount of frost to build up on the inside walls as this may impair cooling. Defrost by turning the unit off, allowing the frost to melt and wiping out the water.
- The lower the ambient temperature, the lower the power usage, in order to maximize efficiency keep the unit in a cool location out of direct sunlight.
- It is recommended to operate the unit on a flat surface, but it will operate at angles up to 30°.
Operation
- Power: Both DC (12 and 24 Volt)
- Battery Protection: Selecting the Low, Med, High positions of the switch (next to the DC power socket), you can choose different levels for battery protection. In the below table you can find the voltages when the compressor stops running (cut-out) and when the compressor restarts working(cut-in)
Battery Protection| 12V CUT-OUT| 12V CUT-IN| 24V CUT-OUT|
24V CUT-IN
---|---|---|---|---
LOW| 10.2±0.3V| 11.2t0.3V| 21.6±0.3V| 23.0±0.3V
MED| 10.7±0.3V| 11.7±0.3V| 22.6±0.3V| 24.0±0.3V
HIGH| 11.7±0.3V| 12.7±0.3V| 24.6±0.3V| 26.0±0.3V
BATTERY PROTECTION PRE-CONFIGURED SETTINGS
- Cable Length Specification The DC cables must have a suitable cross-section for their length (measured from the battery to the unit), according to this table:
Cable Thickness | 12V Max Cable Length | 24V Max Cable Length |
---|---|---|
[mm2] | AWG | [m] |
3. | 14 | 3. |
4 | 12 | 4 |
6 | 10 | 6 |
10 | 8 | 10 |
Temperature setting range :-20°C to 10°C
-
Plug in the DC power cable. Press the button ON/OFF to turn the unit on.
The display on the control panel will turn on and the interior temperature is displayed. -
Press the button AUP or VDOWN button to adjust the temperature the unit aims to achieve. Press the button A to increase or the buttonVto decrease the temperature.
-
When you press the“SET” buttons , it switches the display between’ and °F.
-
Press the button “SET” to enter the economic running mode, the ECO indicator green LED light will be on. Press the button again; the unit will enter the maximum running mode (HH) MAX indicator red LED light will be on.
-
The economic mode runs the compressor at a lower speed to save power; the maximum mode runs the compressor at a higher speed increasing power usage. Maximum mode is useful if the ambient temperature is over 30°C or fast cooling is required.
-
Plug in the DC power. Press the button ON/OFF to turn the unit on. The display on the control panel will turn on and the interior temperature is displayed.
-
If the power supply is cut off or disconnected, the unit will switch off automatically and once the power supply is restored it will automatically switch on again
Cleaning and maintenance
- Clean the appliance inside and out with a clean damp cloth every week. If itis dirty, use sodium bicarbonate dissolved in lukewarm water to clean the unit.
- Never use abrasive products, detergents or soap. After cleaning, wipe out with a clean damp cloth and dry carefully.
- Donot store product inside unit if the unitis not on
- Please wipe dry the inside and close the lid when you are not use it.
- Never clean the unit under running water or in dish washer Do not use sharp objects during cleaning as these can damage the unit.
Troubleshooting
- The unit is not turning on
- Check whether the unit has been turned on
- Check the power supply (try a different power source, i.e. different vehicle or power socket)
- Check whether the plug and the socket have a good connection.
- Check whether the fuse has been burned out or blown. Low refrigeration performance
- Too much product been placed inside the unit
- There is too much warm product inside the unit
- The lid is unlatched / or open
- The lid seal is broken o Problems arising from poor ventilation (ensure at least 4″ around all sides) o The ambient is too high o The temperature setting is too high
- Can hear the sound of running water from inside the unit
- This is normal, due to the flow of refrigerant in the unit.
- Unusual noise when refrigerator is working o The refrigerator is not placed on a level surface If none of the above solves your issue please contact with us.
Error Protection Function
When the electronic control module of compressor malfunctions, display will show ER1 ,ER2,ER3,ER4,ER5 and compressor will stop work. After remove the fault please wait 3 minutes before the system starts operation .When NTC(this means temperature sensor/) failure detected, the display shows ERO,ER9 ,after remove the fault 2 seconds later, the dispaly will show the internal temperature again.
Error Code | Problems | Solution Method |
---|---|---|
ERO | Temperature sensor short circuit (t this point the compressor enters a | |
regular operating mode, work 30 minutes then stop 30 minutes. | Change the |
temperature sensor line
ER1| Input under-voltage protection| 1. Change the battery, 2. Lower battery
protection switch
ER2| DC fan over-current protection| Change the fan
ER3| Compressor start-up problem| Interrupt power and place 30min, then re-
start
ER4| Rotational Speed . compressor is abnormal| Change the main controller
ER5| The temperature of control module is abnormal| Move the fridges in a cool
place , cooling the module then re-start
ERO| Temperature sensor open circuit (at this point the compressor enters a
regular operating mode, work 30 minutes then stop 30 minutes.)| 1.Tighten the
temperature sensor line, 2. Change the temperature sensor line.
International Certification Approvals
Technical Data (DC )
MODEL | EP23499 |
---|---|
CLIMATIC CATEGORY | T/ ST N /SN |
PROTECTIVE CLASSIFICATION
OF ELECTRIC SHOCK RESISTANCE| III
RATED VOLTAGE DC (V)| 12/24V
DC FUSE (A)| 15A
TOTAL INPUT POWER (W)| 55W
RATED CURRENT FOR DC (A)| 4.6A/2.3A
REFRIGERANT (g)| 42g
FOAM VESICANT| C5H10/C-Pentane
**** Guidelines for protection of the environment DISPOSAL : Donot dispose
this product as unsorted municipal waste. Collection of such waste separately
for special treatmentis necessary.
Meaning of crossed-out wheeled dustbin: Donot dispose of electrical appliances
as unsorted municipal waste. Use separate collection facilities.
Contact you local government for information regarding the collection systems
available.
lf electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain, damaging
your health and well-being.
Packing List
Item Quantity Model| Refrigerator| DC Power Cord| AC Adaptor| User’s
manual
---|---|---|---|---
EP23499| 1| 1| 1| 1