NOVY 7240400 Kit Met Monoblock Koolfilter Instruction Manual

June 8, 2024
NOVY

NOVY 7240400 Kit Met Monoblock Koolfilter

INSTRUCTIONS FOR SAFETY AND USE

Further information on Novy products, accessories and services may be found on the internet: www.novy.co.uk These are the installation instructions for the appliance shown on the front. These directions for use make use of a number of symbols. The meanings of the symbols are shown belowNOVY-7240400-Kit-Met-Monoblock-Koolfilter-fig-
\(1\)

Warnings before installation

  • Read the directions for use and the installation instructions before installing and using this appliance. You will find important information here for the assembly and use of the appliance.

  • The appliance is intended exclusively for household use (preparation of food) and excludes all other domestic, commercial or industrial use. Do not use the appliance outside.

  • Keep good care of this manual and pass it on to any person who may use the appliance after you.

  • This appliance complies with the applicable safety instructions. However, inexpert installation may cause personal injury or damage to the appliance.

  • Check the condition of the appliance and the installation fittings as soon as you remove them from the packaging.
    Remove the appliance from the packaging with care. Do not use sharp knives to open the packaging.

  • Do not install the appliance if it is damaged, and in that case inform Novy.

  • Check on the basis of drawing A that all the materials for installation have been supplied.

  • Novy is not liable for damage resulting from incorrect assembly, incorrect connection, incorrect use or incorrect operation.

  • Safety is guaranteed only with expert installation in accordance with the installation manual. The installing technician is responsible for proper operation at the installation location.

  • Metal parts may have sharp edges, and you may injure yourself on them. For that reason, wear protective gloves during installation.

  • Do not convert or alter the appliance.

  • Remove labels and stickers on the appliance with tip for use or installation. The type sticker is to be found behind the grease filter in the appliance. Do not remove it.

THE MONOBLOCK RECIRCULATION FILTER

  • Contemporary, energy-efficient kitchen ventilation: you can’t have the first without the latter. Recirculation offers the solution for this. Recirculation extraction hoods do not remove the cooking fumes, but filter the odour and fat out of the air and then blow the filtered air back into the home.
  • The Novy monoblock filter absorbs unpleasant odours and makes the removal of hot air to the outside unnecessary.
  • The basis of the monoblock filter is an advanced form of activated carbon particles in the shape of minuscule spheres that are bonded to a load-bearing labyrinth structure.
  • Due to the labyrinth structure, the monoblock filter has a limited loss of pressure and maintains a maximum efficiency. This results in efficient extraction, excellent odour absorption and a limited noise level.

USE OF THE MONOBLOCK RECIRCULATION FILTER

  • The monoblock filter is used in combination with a cooker hood/hood or worktop extractor.
  • Before programming and using the recirculation mode, read the operating instructions for your device.
  • For optimal operation of the monoblock recirculation filter, it is important to switch on the extractor before cooking and to respect the after-running time. To do this, read the instructions in the operating instructions for your appliance.
  • Provide adequate ventilation in the kitchen for optimal efficiency of the recirculation system.
  • An indication on the cooker hood or downdraft extractor indicates that the Monoblock recirculation filter needs to be replaced.
  • The lifetime of this Monoblock recirculation filter is indicated on the label on the filter itself. xxxh
  • You can obtain a new monoblock filter from specialist retailers or via the Novy website.

Article number monoblock filter:

7240400 : 7300055 (1x)
7250400 : 7300055 (2x)

Important : Please read the safety and installation instructions before you start.
Turn off the hood power supply in the switch box.

WHAT IN BOX

NOVY-7240400-Kit-Met-Monoblock-Koolfilter-fig-
\(2\)

INSTALLATION

NOVY-7240400-Kit-Met-Monoblock-Koolfilter-fig-
\(3\)

  1. Remove the protective film from the ceiling plate (A). Position the ceiling plate as required (the longest side = longest side of the hood) and attach it to the ceiling using screws (C) and/or plugs (B). Insert the electrical supply cable (F) through the opening in the ceiling plate (A)
  2. Remove the bolts on the suspension frame (E) and slide the suspension frame (E) upwards until it is completely loose. Mount the suspension frame (E) onto the ceiling plate (A) with the spacers (D) between them and attach with the screws (C) (supplied with the hood) to the ceiling.
  3. Insert the noise damper (G) as close as possible to the ceiling plate (A) in the suspension frame (E) and fasten with screws (H). Insert the electrical supply cable (F) through the bottom of the noise damper (G) and connect a plug (Female) (K).
    Mount the hood on the suspension frame (E) at the desired height using the nuts and bolts. The correct 8 bolts (H) must be used.
    Mount the exhaust tube (L) to the noise damper (G) and to the motor. Cut the supplied insulation to size and attach it around the exhaust tube using tape.
    Connect the plug (Male) of the cooker hood with the plug (Female) of the supply cable.
    Screw to the chimney with stainless steel screws (J).
    Switch on the power supply

Assembly of the monoblock filter

NOVY-7240400-Kit-Met-Monoblock-
Koolfilter-fig- \(4\)

  1. A Remove the monoblock filter (D) from the monoblock filter holder (A). Slightly press the locking spring (B) between thumb and forefinger to unlock it.
  2. B Open the bottom panel and remove the grease filter from the cooker hood. Take the monoblock filter holder (A) and place it in the cooker hood with the spring unlocking on the side of the hinges of the bottom plate and fasten it with 6 screws (C).
  3. C Replace the monoblock filter (D) in the monoblock filter holder. D Close the locking spring (B) by squeezing it together and securing it in the provided slot. Replace the grease filter (E) in the cooker hood. Stick the sticker indicating the service life of this monoblock filter next to the opening of the grease filter.
    Close the bottom panel. You can reopen the locking spring (B) by squeezing it together and pulling it backwards. When selecting recirculation, always set the recirculation program on the extractor hood.
    To do so, read the instructions in the operating instructions of your appliance.

Novy nv reserves the right at any time and without reservation to change the structure and the prices of its products.

NOVY nv Noordlaan 6
B – 8520 KUURNE
Tel. 056/36.51.00
Fax 056/35.32.51
E-mail : novy@novy.be
www.novy.be
www.novy.com

France: Tél: 0320.940662
Deutschland und Österreich: Tel: +49 (0)511.54.20.771
Nederland: Tel.: +31 (0)88-0119110
United Kingdom : +44 (0)207 866 2493
España: Tel.: +34 938 700 895
Italia: Tel.: +39 039.20.57.501

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals