NOYAFA PDF Nf-2030 Laser Distance Meter Instruction Manual
- June 8, 2024
- NOYAFA
Table of Contents
Your excellent helper in laser distance test! NEW!
Laser Distance Meter
INSTRUCTION MANUAL
NF-2030 NF-2050
VER: V1
Please read the complete instructions including safety precautions before attempting any testing.
Please read all of the operational guide and safety regulations in this manual before operation. Improper operations without complying with this manual guided could cause damage to the device, influence on measurement result or bodily injury to the user.
The instrument is not allowed to disassemble or repair on any ways. It is forbidden to do any illegal modification or performance change for laser emitter. Please keep it out of reach of children and avoid using by any irrelevant personnel.
It is strictly prohibited to shoot eyes or other parts of body with the laser; it is not allowed to take the laser to shoot any objects’ surface with strong reflecting.
Due to electromagnetic radiation interference to other equipment and devices, please don’t use the meter in the plane or around medical equipment, don’t use it in inflammable, explosive environment.
Discarded batteries or meter device shall not process just like household garbage, please handle them in line with related law and regulations.
Any quality issues or any questions on the meter, please contact local distributors or manufacturer in time, we are ready to offer solutions for you.
Overview
This series of devices are designed to measure Distance ,Area,Volume. which is mainly applied in indoor decoration and design, building construction.
- Measure (short press: single measurement; long press: continous measurement )
- Function switch (short press: distance/area/volume measurement ; long press: unit switch)
- Return / Power button (short press: return; long press: power on or off)
- Record query (press the two buttons together)
- Reference point (press the two buttons together)
Operation
1. Power on or off
Long press for 2 secs to turn on or off the device.
2. Single measurement
short press to start laser, short press again to start measuring.
Then the result will display on the screen immediately.
During work mode, the red icon will flicker, otherwise, it would be invisible.
3. Continous measurement
Long press for 2 secs to enter continous measurement mode, the real-time Max &
Min value will be on the screen. ( below image) In this mode, press or button
to stop measurement. or it will stop if no operation after 3mins.
- Max value
- Min value
- Real-time value
4. Area measurement
Press , it enters area mesurement mode when displays on the screen , then
short press to measure the length and width accordingly, the device will
caculate the area value automatically and display the value on the screen.
5. Volume measurement
Press , it enters volume mesurement mode when displays on the screen , then
short press to measure the length ,width and heigth accordingly, the device
will caculate the volume value automatically and display the value on the
screen.
6. Unit switch
Long press for 2 secs, then you can select the preferred unit.
0.000m → 0.00m→0.00ft, → 0.0 in→0’00”1/16
7. Benchmark
Press + together, you can set the benchmark to measure from the front side ,
or from the end side.
8. Record query
Press + together, you can query the datas measured before. then short press
to read the records. press or button to quit.
Accessories
1 | Laser distance mete | 1pc |
---|---|---|
2 | 1.5V AAA battary | 2pcs |
3 | User manual | 1 pc |
4 | Hanging rope | 1 pc |
5 | Qualification certification | 1 pc |
Specification
Model | NF-2030 | NF-2050 |
---|---|---|
Range | 0.2-30m | 0.2-50m |
Accuracy | ±1.5mm | |
Output | <1mW | |
Wavelength | 620-680nm | |
Test time | 0.2~3S | |
LCD screen | FSTN with backlight | |
Buttons | MEAS,FUNC,POWER | |
Units | m/ft/in/ft+in | |
Benchmark | √ | |
single/continuous measurement | √ | |
Distance/Area/ Volume measurement | √ | |
Data storage | 20 sets | |
Laser auto-off | 30s | |
Auto-off time | 2mins | |
Power supply | 1.5V AAA*2 | |
Working temperature | 0°C~40°C | |
Protection level | IP40 | |
Size | 2034105mm | |
Weight | 44g |
Error reasons and solutions
Code | Reason | Solution |
---|---|---|
203 | High or Low Temperature | Measure at the required temperature range |
220 | Low battery | Replace new battery |
254 | Wrong calculation | Measure again in correct operation |
255 | Weak signal | Test strong reflection ability of target |
256 | Strong signal | Don’t measure under strong light |
257 | Out of measure range | Measure within the range |
300 | Hardware error | Restart, or contact dealer if it happens again |
Overview–Laser distance meters
NF-2140 NF-2170 NF-2100
NF-2650 NF-2680 NF-271
NF-2130L NF-2330 NF-2230
NF-272L NF-273L NF-274L
Your excellent helper in laser distance test!
Documents / Resources
|
NOYAFA PDF Nf-2030 Laser Distance
Meter
[pdf] Instruction Manual
PDF Nf-2030 Laser Distance Meter, PDF Nf-2030, Laser Distance Meter, Distance
Meter
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>