PACKAGE CONTENTS
PART DESCRIPTION | QUANTITY |
---|---|
A | Mounting Bracket |
B | |
C | |
D | Downrod Assembly |
E | Canopy |
F | Switch Housing Assembly |
G | Motor Assembly |
H | Blade Iron |
I | Blade |
J | Fan Switch Cover |
K | Fan Finial |
L | Light Kit |
PART | DESCRIPTION |
--- | --- |
M | Bulb |
N | Glass Shade |
O | Light Finial Cap |
P | Light Finial |
Q | Motor Housing Cover |
R | Bottom Housing(preassembled onSwitch Housing Assembly (F)) |
S | Light Switch Cover |
T | Celvis Pin(preassembled on Downrod Assembly (B) |
U | Hairpin Clip(preassembled on Downrod Assembly (B) |
V | Bar |
W | Spring Washer |
HARDWARE CONTENTS
SAFETY INFORMATION
READ AND SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble,
operate or install the product.
- All electrical connections must comply with local codes, ordinances or the National Electric Code (NEC). Contact your municipal building department to inquire about your local codes, permits and/or inspections.
- Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse or by removing the fuse or by switching off circuit breaker.
- Do not connect this fixture to an electrical system that does not provide a means for equipment grounding. Never use a fixture in a two-wire system that is not grounded.
- If you are not sure your lighting system has a grounding means, do not attempt to install this fixture. Contact a qualified, licensed electrician for information regarding proper grounding methods as required by the local electrical code in your area.
- Make sure the installation site you choose allows a minimum clearance of 7 ft. from the blades to the floor and at least 30 in. from the ends of the blades to any obstruction.
- If a dimmer control switch is used with this fixture, obtain professional advice to determine the correct type and electrical rating required.
- The lighting fixture must be positioned so there is at least 1.64 ft. between the bulb and any illuminated surface.
- For supply connections, if the conductor of a fan is identified as a grounded conductor, then it should be connected to a grounded conductor power supply. If the conductor of a fan is identified as an ungrounded conductor, then it should be connected to an ungrounded conductor power supply. If the conductor of a fan is identified for equipment grounding, then it should be connected to an equipment-grounding conductor.
DANGER
- Installing a fixture into an electrical system without a proper grounding means could allow metal parts of the fixture to carry electrical currents. If any of the fixture wires, wire connections or splices are broken, cut or loose during the mounting or normal operation of the fixture, under such condition, anyone coming in contact with the fixture is subject to electrical shock, which could cause serious injury or death.
- Connection of the bare or green fixture ground wire to the black or white house wires may allow metal parts of the fixture to carry electrical currents. Under this condition anyone coming in contact with the fixture will receive electrical shock, which could cause serious injury or death.
- Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires to have contact with any surface having a sharp edge. Doing so may damage or cut the wire insulation, which could cause serious injury or death from electric shock.
WARNING
- Risk of fire. Most dwellings built before 1985 have supply wire rated for 140°F. Consult a qualified electrician before installation.
- To reduce the risk of fire or electric shock, do not use this fan with any solid state fan speed device or variable speed control.
- To reduce the risk of personal injury, do not bend the blade brackets when installing the brackets, balancing or cleaning the fan.
- Do not insert foreign objects in between rotating fan blades.
- Do not install or use the fan if any part is damaged or missing.
- To reduce the risk of fire, electric shock or personal injury, mount to outlet box marked ‘ACCEPTABLE FOR FAN SUPPORT OF 35 LBS OR LESS’ and use mounting screws provided with the outlet box and/or support directly from building structure. Most outlet boxes commonly used for the support of luminaries are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.
- Before servicing or cleaning the unit, switch power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
CAUTION
- Do not use bulbs having a wattage greater than the maximum value stated on the fixture and in this manual. Using a higher wattage bulb than specified will increase fixture temperature and increase risk of fire.
PREPARATION
Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list and hardware contents list. If any part is missing or damaged, do not attempt to assemble the product.
Estimated Assembly Time: 45 minutes
Tools Required for Assembly (not included): Phillips Screwdriver, Step Ladder,
Tape, Pliers and Wire Cutters.
INITIAL INSTALLATION INSTRUCTIONS
-
Turn off circuit breakers and wall switch to the fan supply line leads.
DANGER: Failure to disconnect power supply prior to installation may result in serious injury or death. -
a. Choose the desired mounting method:
A. Standard Mounting: Standard mounting is best suited for ceilings 8 ft. or higher. For taller ceilings youmay want to use a longer downrod (not included).
B. Angle Mounting: Angle-style mounting is best suited for angled or vaulted ceilings. A longer downrod is sometimes necessary to ensure proper blade clearance. If using the angle mount, make sure the ceiling angle is not steeper than 20°.
Note: Flushmount and closemount options are not available for this item.
b. It is required at least 30 inch from blade tip to nearest wall or
obstruction. Check downrod length to ensure 7feet from bottom edge of blade to
the floor.
-
Check existing outlet box (not included) to ensure it is securely fastened to at least two points in a structural ceiling member and can support the full weight of the fan. Once verified, install mounting bracket (A) to theoutlet box using the screws and washers provided with the outlet box.
DANGER: A loose outlet box can cause the fan to wobble and increase the fan’s potential to fall, whichcould result in serious injury or death.
Note:If using the angel mount, make sure open end of mounting bracket (A) is installed facing the higher pointof the ceiling -
Remove the motor screws and motor blocks from each motor of motor body. Discard motor blocks and save the motor screws for later use.
-
Attach metal bracket to motor assembly (G) on both ends and securely tighten with four bars (V) and spring washers (W) provided.
-
Feed 4-pin connectors from metal brackets through motor housing cover (Q) . Attach 4-pin connectors out of motor assembly (G) to 4-pin connectors from metalbrackets. Secure motor housing cover (Q) to motor assembly ( G ) with motor housing cover screws (EE).
Note: The two connectors have keyholes that must be mated correctly before they can be engaged. -
. Loosen the two coupling screws preassembled in coupling on top housing, but do not remove them.
Remove the hairpin clip (U) and celvis pin (T) from the downrod assembly (B). Retain for later use.
Note: Make sure to keep loose hardware separate to avoid confusion during installation.
-
Place downrod assembly (B) through canopy (C),canopy cover (D) and coupling cover (E)
-
Feed power wires from switch housing assembly (F)through downrod assembly (B), then insert downrod assembly (B) into the coupling on switch housing assembly (F). Align the hole on downrod assembly (B) ) , to hole on coupling, then re-install celvis pin (T).
Re-attach hairpin clip (U) into celvis pin (T) until it snapsinto place then tighten the two previously loosened screws on coupling. -
.Cut off excess fixture wires, leaving approximately 6 to 9 inches above the top of the downrod assembly (B). Strip1/2 inch insulation from the end of each fixture wire.
CAUTION: Ensure all screws are tight before moving onto the next step.
- Carefully lift the assembly and rest the hanger ball of downrod assembly (B) on the mounting bracket (A) attached to the outlet box.
NOTE: Unlike a standard circular fan, the mountingbracket (A) for this item does not have a tab, which locks the fan into a specific position. This allows you the freedom to rotate the fan’s linear motor housing 360° so it can be correctly oriented with the layout ofyour room.
WIRING INSTRUCTIONS
WARNING: To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before hanging.
WARNING:If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.
WARNING: If house wires are different colors than referred to in the following steps, stop immediately. A professional electrician is recommended to determine proper wiring.
WARNING: If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.
-
Connect the GREEN wires from the hanger ball of downrod assembly (B) and mounting bracket (A) to thesupply ground (GREEN or bare color). Securely connect wires using wire connector (AA) supplied.
-
Securely connect the fan WHITE wire to the supply WHITE wire using wire connector supplied. Securely connect the fan BLACK and BLUE wires to the supply BLACK wire using wire connector supplied
-
Wrap electrical tape (not included) around each wire connector and make sure no bare wire or wire strands are visible after making connections.
Then, turn wires upward and carefully push them into the outlet box; make sure the WHITE and GREENconnections are on one side and the BLACK connections are on the other side.
FINAL INSTALLATION INSTRUCTIONS
-
Loosen but do not remove the two preassembled mounting screws on mounting bracket (A). Lift canopy(C) up and align the keyholes on the bottom of canopy (C) with mounting screws on mounting bracket (A), then twist canopy (C) clockwise. Tighten mounting screwssecurely.
-
Slide canopy cover (D) over the mounting screws visible in canopy (C). Rotate canopy cover (D) clockwise until itlocks into place.
NOTE: You may need to adjust the mounting screws until the canopy (C) and canopy cover (D) have a snug fit.
-
Position one blade iron (H) under blade (I). Insert three blade screws (BB) through blade (I) and into blade iron (H). Tighten each blade screw (BB) evenly, starting withthe center screw. Repeat for the remaining blade assemblies
-
Position one completed blade assembly under one motor of motor assembly (G). Align the holes on motor and blade iron (H) first, then adjust the slot on the switch housing over the holes. Insert one motor screws (CC) through the slot on the switch housing, and partially tighten.
Repeat for the remaining blade assemblies. Securely tighten all motor screws (CC) provided in hardware and previously removed in. -
Attach the fan switch cover (J) to switch housing on motor of motor assembly (G), securing with fan finial (K). Repeat for the other motor of motor assembly **(G)
**
- Remove three set screws preinstalled on bottom housing (R) of switch housing assembly (F) and save them for later use.
NOTE: Make sure to keep loose hardware separate to avoid confusion during
installation.
To install the fan without the light kit (L), skip to Step 11
To install the fan with the light kit (L), proceed to step 7.
- To install the light kit (L), attach the connector preassembled on light kit (L) to the connector preassembled on bottom housing **(R)
**
- Align the cutout on the light kit (L) with the reverse switch on the bottom housing (R). Attach the light kit (L) to the switch housing assembly (F) using the three setscrews previously removed (step 6). Tighten securely, then install bulbs (M) into each socket
CAUTION: If you replace bulbs with over 190 watts, the fixture will automatically turn off. When replacingbulbs, ensure bulb wattage is below 190 watts.
-
Lift the glass shade (N) up to the light kit (L), allowing the preassembled threaded rod and pull chain to go through the hole in the bottom of the glass shade (N).
While holding the glass shade (N), guide the threadedrod and pull chain through the appropriate holes on the light finial cap (O). Secure it with light finial (P).
-
Connect the fobs (DD) to the appropriated pull chains. Assembly is now complete.
-
For assembly without the light kit (L), remove the preassembled screw in the middle of bottom housing(R) and disassemble bottom housing (R) from switch housing assembly (F). Save screw for later use.
-
Remove the preassembled wiring harness (with pull chain, 6-pin connector and plugs) from the light kit **(L).
**
- Remove the bell mouth nut from pull chain and pass the pull chain leg throuth the round hole on the bottom housing (R). Tighten it with bell mouth nut. Attach the6-pin connector from the wiring harness to the 6-pin connector preassembled on bottom housing **(R).
**
-
Attach the 9-pin connector preassembled on bottom housing (R) to the 9-pin connector from switch housing assembly (F). Then, re-attach the bottom housing (R)to the switch housing assembly (F) with previously removed screw (Step 11)
-
Align the cutout on the light switch cover (S) with the pull chain on the bottom housing (R). Attach the light switch cover (S) to the bottom housing (R) with the three set screws previously removed (step 6)
Tighten securely. -
Connect the fob (DD) marked with a fan image to the pull chain. You can discard the fob (DD) marked with the light image.
Assembly is now complete.
OPERATING INSTRUCTIONS
-
The fob ( DD ) marked with a fan image is for motor speed control: High, Medium, Low and Off. Pull once for each position.
The fob (DD) marked with a lamp image controls the light either On or Off with each pull of the chain. -
When the season changes, you may want to change thedirection the fan spins.
In warmer weather, counterclockwise rotation creates a downward airflow, which cools the air. Push the reverse switch located on switch housing assembly (F) LEFT andsee a SUN icon.
In cooler weather, clockwise rotation creates an upward airflow, which moves hot air from the ceiling. Push the reverse switch located on switch housing assembly (F) RIGHT and see a SNOWFLAKE icon.
NOTE: Turn off and wait for fan to stop before flipping the reverse
switch.
NOTE: Use a small screwdriver or ballpoint pen to move the reverse switch
if you have difficulty doing so by hand.
NOTE: Make sure reverse switch is firmly in left or right position. Fan
will not operate when switch is in the middle
- Change the fan angle by adjusting the bars on the two sides, and securely tighten the bars after choosing a predesigned degree.
NOTE: Each fan motor can adjust to an max. angel of 20°.
CARE AND MAINTENANCE
Important: Shut off main power supply before beginning any maintenance. Do not use water or a damp cloth to clean the ceiling fan.
- At least twice each year, tighten all screws and lower canopy to check mounting plate screws.
- Clean fan housing with only a soft brush or lint-free cloth to avoid scratching the finish. Clean blades with a lint-free cloth. You may occasionally apply a light coat of furniture polish to wood blades for added protection
- Bulb replacment: Use two 6.5-watt max. type A-15 LED bulbs. CFL bulbs are not recommended for this item.
TROUBLESHOOTING
PROBLEM | PROBABLE CAUSE | CORRECTIVE ACTION |
---|---|---|
Fan sounds noisy |
- Set screws are loose.
- Normal noise.
- Wire connectors inside switch housing rattling.
- Cracked blade.
- The distance from canopy to ceiling is too great.
- Faulty light bulb installation.
- Glass is not secure.
|
- Tighten all set screws.
- Allow “break-in” period of 24 hours. Most noises associated with a new fan will disappear after this period.
- Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing.
- Replace blades.
- Make sure upper canopy is a short distance from ceiling. It should not touch the ceiling.
- Make sure light bulb is tight in socket and does not touch on glass shade.
- Secure the glass.
Fan wobbles|
- Hanger bracket and/or ceiling outlet box is not securely fastened
- Set screw in downrod assembly is loose.
- Fan hanger ball is not properlyseated in canopy tabs.
- Set screw in motor coupling is loose.
- Blade is loose.
- Blade holders are loose.
- Blade out of balance.
- Fan too close to vaulted ceiling.
- Fan not securely mounted.
|
- Tighten the hanger bracket screws to the outlet box, and/or secure outlet box.
- Tighten the set screw in the downrod assembly.
- Turn power off, support the fan very carefully, and check that the hanger ball is properly seated.
- Raise motor coupling up and tighten set screws securely.
- Check that all blades are screwed firmly into bladeholders.
- Check to be sure the fan blade irons seat firmly and uniformly on the surface of the motor. If flanges are seated incorrectly, loosen the flange screws and
- Interchange two adjacent blades; this will redistributethe weight and possibly result in smoother operation.
- Lower or move fan. Extension downrods may be ordered.
- Make sure canopy and mounting bracket are tightened securely to ceiling joist.
Fan does not start|
- Power turned off, fuse blown or circuit breaker tripped.
- Loose wire connections or wrong connections.
- Motor reversing switch not engaged.
- Pull chain switch not “on”.
|
-
Turn power on, replace fuse or reset breaker.
-
a. Turn power off and loosen canopy; check all connections according to section WIRING INSTRUCTIONS on .
b. Check the plug connection in the switch housing. -
Push switch firmly right or left. Fan will not operate when switch is in the middle.
-
Pull switch chain.
Light does not work|
- Wrong wire connection.
- Bulb is burned out.
|
- Refer to Step 7, to ensure all wire connections were done correctly.
- Replace the bulbs.
LIMITED LIFETIME WARRANTY
The manufacturer warrants this fan to be free from defects in workmanship and
material present at time of shipment from the factory for life (with
limitations) from the date of purchase.
This warranty applies only to the original purchaser. The manufacturer agrees
to correct such defect at no charge or, at our option, replace the ceiling fan
with a comparable or superior mode
To obtain warranty service, present a copy of your sales receipt as proof of
purchase. All cost of removal andreinstallation are the expressed
responsibility of the purchaser. Any damage to the ceiling fan by accident,
misuse orimproper installation, or by affixing accessories not produced by
this warranty, are at the purchaser’s ownresponsibility. The manufacturer
assumes no responsibility whatsoever for fan installation during the limited
lifetimewarranty. Any service performed by anunauthorized person will render
the warranty invalid.
Due to varying climatic conditions, this warranty does not cover changes in
brass finish, rusting, pitting, tarnishing,corroding or peeling. Brass finish
fans maintain their beauty when protected from varying weather conditions.
Any replacement of defective parts for the ceiling fan must be reported within
the first year from the date ofpurchase. For the balance of the warranty, call
our customer service department at
888-251-1003 for return authorization
and shipping instructions so that we may repair or replace the ceiling fan.
Any fan or parts returnedimproperly packaged is the sole responsibility of the
purchaser. There is no further expressed warranty. Themanufacturer disclaims
any and all implied warranties.
The duration of any implied warranty which can not be disclaimed is limited to
the lifetime limited period as specifiedin our warranty. The manufacturer
shall not be liable for incidental, consequential or special damages arising
at or inconnection with product use or performance except as may other wise be
accorded by law. This warranty gives youspecific legal rights, and you also
have other rights which vary from state to state. This warranty supersedes all
priorwarranties. The duration of any implied warranty which can not be
disclaimed is limited to the lifetime limited periodas specified in our
warranty. The manufacturer shall not be liable for incidental, consequential
or special damagesarising at or in connection with product use or performance
except as may other wise be accorded by law. Thiswarranty gives you specific
legal rights, and you also have other rights which vary from state to state.
This warranty supersedes all prior warranties.
NOTE : A small amount of “ wobble ” is normal and should not be considered a defect.
REPLACEMENT PART LIST
Part | Description | Part# |
---|---|---|
A | Mounting Bracket | A102-0075036 |
B | Downrod Assembly | A103-0156529 |
C | Canopy | A101-0161529 |
D | Canopy Cover | A108-0013529 |
E | Coupling Cover | A126-0114529 |
H | Blade Iron | A143-0159529 |
I | Blade | A141-0331002 |
J | Fan Switch Cover | A122-0096529 |
K | Fan Finial | A186-0096529 |
L | Light Kit | A187-0245529 |
N | Glass Shade | A182-0591001 |
O | Light Finial Cap | A183-0265529 |
P | Light Finial | A186-0119529 |
Q | Motor Housing Cover | A106-0485529 |
S | Light Switch Cover | A124-0143529 |
V | Bar | B171-0343529 |
W | Spring Washer | |
AA | Wire Connectors | B168-0687529 |
BB | Blade Screw | |
CC | Motor Screw | |
DD | Fob | |
EE | Motor Housing Cover Screw |
For replacement parts, call our customer service department at 888-251-1003 8 a.m. -8 p.m., EST, Monday – Sunday. You could also contact us at partsplus@lowes.com or visit www.lowespartsplus.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>