SGS V5 Cell Module Scientifically Tested Gas and Odor Filter for IQAir HealthPro Series Air Purifier User Guide

June 16, 2024
SGS

SGS V5 Cell Module Scientifically Tested Gas and Odor Filter for IQAir HealthPro Series Air Purifier

SGS V5 Cell Module Scientifically Tested Gas and Odor Filter for IQAir
HealthPro Series Air Purifier

Specification

Sample Name: Pure Illusion Crystalline Gas & Odor Management Filter (195893286638)
The above sample(s) and information were provided by the client.

SGS Job No.: SZP23-024726
Sample Receiving Date: Oct 26, 2023
Testing Period: Oct 26, 2023 ~ Oct 31, 2023
Test Requested: Select test(s) as requested by the client.
Test Method (s) : Please refer to next page(s).
Test Result (s): Please refer to next page(s).

Test Requirement

Test Requirement Conclusion

EU RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU- Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs), Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP) and Diisobutyl phthalate (DIBP)| Pass

Test Part Description

SN ID Sample No. SGS Sample ID Description
SN1 A3 SZX23-0026274-0001.C003 Black material

Remarks:

  1. 1 mg/kg = 1 ppm = 0.0001%
  2. MDL = Method Detection Limit
  3. ND = Not Detected (< MDL)
  4. “-“ = Not Regulated

EU RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU- Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs), Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP) and Diisobutyl phthalate (DIBP)

Test Method: With reference to IEC 62321-4:2013+AMD1:2017, IEC 62321-5:2013, IEC 62321-7-2:2017,  IEC 62321-6:2015 and IEC 62321-8:2017, analysis was performed by ICP-OES, UV-Visand GC-MS.

Test Item(s) Limit Unit(s) MDL A3
Cadmium(Cd) 100 mg/kg 2 ND
Lead (Pb) 1000 mg/kg 2 ND
Mercury (Hg) 1000 mg/kg 2 ND
Hexavalent Chromium (Cr(VI)) 1000 mg/kg 8 ND
Poly Bromobiphenyl (PBBs) 1000 mg/kg ND
Mono Bromobiphenyl (MonoBB) mg/kg 5 ND
Dibromobiphenyl (DiBB) mg/kg 5 ND
Tribromo biphenyl (TriBB) mg/kg 5 ND
Tetrabromodiphenyl (TetraBB) mg/kg 5 ND
Pentabromodiphenyl (PentaBB) mg/kg 5 ND
Hexabromobiphenyl (HexaBB) mg/kg 5 ND
Hepta Bromobiphenyl (HeptaBB) mg/kg 5 ND
Octabromodiphenyl (OctaBB) mg/kg 5 ND
Nona Bromobiphenyl (NonaBB) mg/kg 5 ND
Hexabromobiphenyl (DecaBB) mg/kg 5 ND
Polybromo Diphenyl ether(PBDEs) 1000 mg/kg ND
Mono Bromodiphenyl Ether (MonoBDE) mg/kg 5 ND
Dibromodiphenyl Ether (DiBDE) mg/kg 5 ND
Tri Bromodiphenyl Ether (TriBDE) mg/kg 5 ND
Tetrabromodiphenyl Ether (TetraBDE) mg/kg 5 ND
Pentabromodiphenyl Ether (PentaBDE) mg/kg 5 ND
Hexabromodiphenyl Ether (HexaBDE) mg/kg 5 ND
Hepta Bromodiphenyl Ether (HeptaBDE) mg/kg 5 ND
Octabromodiphenyl Ether (OctaBDE) mg/kg 5 ND
Nona Bromodiphenyl Ether (Nona BDE) mg/kg 5 ND
Decabromodiphenyl Ether (DecaBDE) mg/kg 5 ND
Dibutyl Phthalate(DBP) 1000 mg/kg 50 ND
Benzyl Butyl Phthalate(BBP) 1000 mg/kg 50 ND
Test Item(s) Limit Unit(s) MDL A3
--- --- --- --- ---
Bis-(2-ethylhexyl) Phthalate(DEHP) 1000 mg/kg 50 ND
Diisobutyl Phthalate(DIBP) 1000 mg/kg 50 ND

Notes:

  1. The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
  2. IEC 62321 series is equivalent to EN 62321 series.
  3. The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, from 22 July 2021.
    Unless otherwise stated, the decision rule for conformity reporting is based on Binary Statement for Simple Acceptance Rule (w=0) stated in ILAC-G8:09/2019.

Elements Testing Flow Chart

These samples were dissolved totally by pre-conditioning method according to below flow chart.

Elements Testing Flow Chart

Hexavalent Chromium (Cr(VI)) Testing Flow Chart

Hexavalent Chromium \(Cr\(VI\)\) Testing Flow Chart

PBBs/PBDEs Testing Flow Chart

PBBs/PBDEs Testing Flow Chart

Phthalates Testing Flow Chart

Phthalates Testing Flow Chart

Sample Photo

Sample Photo
SGS authenticate the photo on original report only End of Report

Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch

Signature
Mescal Ye
Approved Signatory

Scan to see the report
QR code
F74D11F9

Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at http://www.sqs.com/en/Terms-and-Conditions.aspx and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sqs.com/en/Terms-and- Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report refer only to the sample(s) tested .
Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86-755)83071443, or email: CN.Doccheck@sgs.com

Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals