SGS V5 Cell Module Scientifically Tested Gas and Odor Filter for IQAir HealthPro Series Air Purifier User Guide
- June 16, 2024
- SGS
Table of Contents
SGS V5 Cell Module Scientifically Tested Gas and Odor Filter for IQAir HealthPro Series Air Purifier
Specification
Sample Name: Pure Illusion Crystalline Gas & Odor Management Filter
(195893286638)
The above sample(s) and information were provided by the client.
SGS Job No.: SZP23-024726
Sample Receiving Date: Oct 26, 2023
Testing Period: Oct 26, 2023 ~ Oct 31, 2023
Test Requested: Select test(s) as requested by the client.
Test Method (s) : Please refer to next page(s).
Test Result (s): Please refer to next page(s).
Test Requirement
Test Requirement | Conclusion |
---|
EU RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU- Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs), Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP) and Diisobutyl phthalate (DIBP)| Pass
Test Part Description
SN ID | Sample No. | SGS Sample ID | Description |
---|---|---|---|
SN1 | A3 | SZX23-0026274-0001.C003 | Black material |
Remarks:
- 1 mg/kg = 1 ppm = 0.0001%
- MDL = Method Detection Limit
- ND = Not Detected (< MDL)
- “-“ = Not Regulated
EU RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU- Lead, Mercury, Cadmium, Hexavalent chromium, Polybrominated biphenyls (PBBs), Polybrominated diphenyl ethers (PBDEs), Bis(2-ethylhexyl) phthalate (DEHP), Butyl benzyl phthalate (BBP), Dibutyl phthalate (DBP) and Diisobutyl phthalate (DIBP)
Test Method: With reference to IEC 62321-4:2013+AMD1:2017, IEC 62321-5:2013, IEC 62321-7-2:2017, IEC 62321-6:2015 and IEC 62321-8:2017, analysis was performed by ICP-OES, UV-Visand GC-MS.
Test Item(s) | Limit | Unit(s) | MDL | A3 |
---|---|---|---|---|
Cadmium(Cd) | 100 | mg/kg | 2 | ND |
Lead (Pb) | 1000 | mg/kg | 2 | ND |
Mercury (Hg) | 1000 | mg/kg | 2 | ND |
Hexavalent Chromium (Cr(VI)) | 1000 | mg/kg | 8 | ND |
Poly Bromobiphenyl (PBBs) | 1000 | mg/kg | – | ND |
Mono Bromobiphenyl (MonoBB) | – | mg/kg | 5 | ND |
Dibromobiphenyl (DiBB) | – | mg/kg | 5 | ND |
Tribromo biphenyl (TriBB) | – | mg/kg | 5 | ND |
Tetrabromodiphenyl (TetraBB) | – | mg/kg | 5 | ND |
Pentabromodiphenyl (PentaBB) | – | mg/kg | 5 | ND |
Hexabromobiphenyl (HexaBB) | – | mg/kg | 5 | ND |
Hepta Bromobiphenyl (HeptaBB) | – | mg/kg | 5 | ND |
Octabromodiphenyl (OctaBB) | – | mg/kg | 5 | ND |
Nona Bromobiphenyl (NonaBB) | – | mg/kg | 5 | ND |
Hexabromobiphenyl (DecaBB) | – | mg/kg | 5 | ND |
Polybromo Diphenyl ether(PBDEs) | 1000 | mg/kg | – | ND |
Mono Bromodiphenyl Ether (MonoBDE) | – | mg/kg | 5 | ND |
Dibromodiphenyl Ether (DiBDE) | – | mg/kg | 5 | ND |
Tri Bromodiphenyl Ether (TriBDE) | – | mg/kg | 5 | ND |
Tetrabromodiphenyl Ether (TetraBDE) | – | mg/kg | 5 | ND |
Pentabromodiphenyl Ether (PentaBDE) | – | mg/kg | 5 | ND |
Hexabromodiphenyl Ether (HexaBDE) | – | mg/kg | 5 | ND |
Hepta Bromodiphenyl Ether (HeptaBDE) | – | mg/kg | 5 | ND |
Octabromodiphenyl Ether (OctaBDE) | – | mg/kg | 5 | ND |
Nona Bromodiphenyl Ether (Nona BDE) | – | mg/kg | 5 | ND |
Decabromodiphenyl Ether (DecaBDE) | – | mg/kg | 5 | ND |
Dibutyl Phthalate(DBP) | 1000 | mg/kg | 50 | ND |
Benzyl Butyl Phthalate(BBP) | 1000 | mg/kg | 50 | ND |
Test Item(s) | Limit | Unit(s) | MDL | A3 |
--- | --- | --- | --- | --- |
Bis-(2-ethylhexyl) Phthalate(DEHP) | 1000 | mg/kg | 50 | ND |
Diisobutyl Phthalate(DIBP) | 1000 | mg/kg | 50 | ND |
Notes:
- The maximum permissible limit is quoted from RoHS Directive (EU) 2015/863.
- IEC 62321 series is equivalent to EN 62321 series.
- The restriction of DEHP, BBP, DBP and DIBP shall apply to medical devices, including in vitro medical devices, and monitoring and control instruments, including industrial monitoring and control instruments, from 22 July 2021.
Unless otherwise stated, the decision rule for conformity reporting is based on Binary Statement for Simple Acceptance Rule (w=0) stated in ILAC-G8:09/2019.
Elements Testing Flow Chart
These samples were dissolved totally by pre-conditioning method according to below flow chart.
Hexavalent Chromium (Cr(VI)) Testing Flow Chart
PBBs/PBDEs Testing Flow Chart
Phthalates Testing Flow Chart
Sample Photo
SGS authenticate the photo on original report only End of Report
Signed for and on behalf of
SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
Mescal Ye
Approved Signatory
Scan to see the report
F74D11F9
Unless otherwise agreed in writing, this document is issued by the Company
subject to its General Conditions of Service printed overleaf, available on
request or accessible at http://www.sqs.com/en/Terms-and-Conditions.aspx
and, for electronic format documents, subject to Terms and Conditions for
Electronic Documents at http://www.sqs.com/en/Terms-and-
Conditions/Terms-e-Document.aspx. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder
of this document is advised that information contained hereon reflects the
Company’s findings at the time of its intervention only and within the limits
of Client’s instructions, if any. The Company’s sole responsibility is to its
Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents.
This document cannot be reproduced except in full, without prior written
approval of the Company. Any unauthorized alteration, forgery or falsification
of the content or appearance of this document is unlawful and offenders may be
prosecuted to the fullest extent of the law. Unless otherwise stated the
results shown in this test report refer only to the sample(s) tested .
Attention: To check the authenticity of testing /inspection report &
certificate, please contact us at telephone: (86-755)83071443, or email:
CN.Doccheck@sgs.com