CureUV Wall Mountable Air Purifier and Sanitizer Instruction Manual
- June 8, 2024
- cureuv
Table of Contents
GermAwayUV High Occupancy 150 Watt
Wall Mountable Air Purifier and Sanitizer Instruction Manual
WARRANTY
The unit is covered for 12 months.
The following are not covered by the Warranty
Accidental or deliberate damage caused by human factors.
Damage caused by repairs carried out by unauthorized persons.
Normal wear and tear during use.
Filter screen
Damage caused due
Damage caused due to failure to follow the correct instructions for
installation and uses.
Please read the manual before operation.
The use of this machine must be in accordance with the rules prescribed by
the operation
Do not use in areas where there is a risk of ammable or an explosive
atmosphere
Best results are achieved when doors and windows of the room are closed
The unit must not be connected to the power supply during installation,
cleaning or maintenance
Do not cover or block the air inlet or outlet of the machine
Do not insert anything into the grills of the machine, this could result in re
or electric shock,
DDo not spill any liquid on the machine.
The power must be disconnected before opening the covers to avoid being
exposed to UVC.
The power supply must be single phase with a ground connection
Installation of wall bracket:
- Pick a location close to a power outlet and with adequate space around the unit.
- If the wall is suitable, use the supplied screws, if not, be sure to attach the bracket securely using an appropriate xing method.
- Hang the machine onto the bracket, ensuring it is attached properly.
- Lift the front cover, remove the lters by lifting their bottom edge and pulling them towards you slightly then, sliding them down.
- Check the UV bulbs are all seated correctly in their sockets, and remove the transit twist ties.
- Replace the lters by sliding them up and lifting the bottom edge back behind the clips. Close the cover.
- Plug in the power lead.
FOR THE BEST RESULTS
Close the doors and windows of the room that the unit is in.
Plug in the power and the power light will illuminate.
This machine utilises an ultraviolet germicidal lamp and titanium dioxide
photo catalytic lter screen, it can be safely operated in an occupied area.
Remote control instructions
To turn unit on or off, press the red “ON/OFF” button. The clock will show in
the display.
To set the Time (All times are 24 hour clock), Press the “CLOCK” button and
then use the up and down keys to set the digit, press the “CLOCK” button to
move to the next digit, repeat until the correct time is displayed.
Press the “PURIFICATION’ key to start a filter only run, press it again to
turn the unit off.
Pressing the “DISINFECTION” key will turn on the UVC for sterilisation, press
it again to turn the unit off
The “SWING FLAP’ key will start or stop the air deflection flap.
To alter the air flow, press “WIND SPEED’ and the up or down keys.
When the unit is running, you can set it to turn of automatically by pressing
“TIME SETTING’ key followed by the up or down key this set a run time, press
the “TIME SETTING* key again and the unit will turn off after the desired
time has elapsed.
Pressing the “CUMULATIVE TIME” key will show you the total time runtime for
the unit.
To program a schedule timer.
- Press the “SETTING” button.
- For the Start time. Use the up and down keys to set the rst digit, press “TIME SETTINGS” to move to the next digit, repeat until the correct time is shown.
- Press the “Setting” button again.
- For the end time, Use the up and down keys to set the rst digit, press “TIME SETTINGS” to move to the next digit, repeat until the correct time is shown.
- Press the “Setting” button again.
The unit will turn on at the rst time set, and off at the second time set.
Up to 6 times can be set throughout the day.
Performance and main features
The machine uses an ultraviolet germicidal lamp along with a lter screen, and
can be used in occupied areas
Working Conditions
-
Power supply: AC110V±22V; Power frequency: 50HZ±1HZ
-
Environmental parameters:
Ambient temperature range: -5C~40C
Relative humidity range: 65%~85%:
Atmospheric pressure range: 800hpa~1060hpa -
Safety classi cation: equipment of class II type B.
Suggested applications
These units can be used for air disinfection in many locations including:-
homes, hospitals, pharmaceutical plants, food plants, hotels, kindergartens,
schools, food and catering, public places of entertainment, offices, canteens.
Main bactericidal factors and strength.
The main bactericidal method of this machine is from ultraviolet radiation,
the intensity of each UV germicidal lamp >200w/cm2 (1m from the machine).
Targeted microbiological category.
Common airborne bacteria.
The main structure of the product and working principle
Incoming air———> Filter screen——-> Fan——–> UVC Lamps——> Clean air after
disinfection 110 volts AC———-> Control system———–> Negative Ions——————-^
Main technical parameters and specications
Each UV sterilization lamp radiation intensity >200w/cm2 (1m from the machine)
Ultraviolet light outside the machine: <1w/cm2 (1cm from the machine)
Ozone concentration: <0.04mg/m3
Noise: <55dB
It is recommended that the UV germicidal lamp should be regularly replaced
(approx 5000 hours),
Clean the primary, medium efficiency lter once every six months and the HEPA
lter as required.
Trouble Shooting
When the following occur, please carry out the suggestedx before contacting
support.
ISSUE | SUGGESTED REMEDY |
---|---|
Will not turn on | Is there power to the unit? |
check the supply
Is the front cover closed properly
Odour when the unit is running| Check the condition of the main filter replace
if necessary
An increase in volume when operating| Check the condition of the HEPA filter
Clean the filter carefully with a vacuum cleaner, if the situation does not
improve, replace the HEPA filter
Filtration system not coming on automatically| This could be due to the units
location in the room not allowing the auto feature to work, turn on manually
or increase the air flow to “High” with the “Wind speed” button
The run light is not on| Check the power and fuse
The UV light is not working| Check the bulb and the ballast
The fan is not running| Check the fan is on with the “Wind speed” button
No responce to the remote control| Check the batteries in the remote, replace
with new batteries if necessary
Other than user serviceable parts, lters and bulbs, under no circumstances
should the owner attempt to effect a repair or replace parts. The integrity and
safety of unit could be compromised and no responsibility will be taken for
any injury to a person or damage to property these actions may result in.
Other than changing the bulbs, cleaning or replacing the lters there are no
user serviceable parts, do not attempt to dismantle the unit yourself, this
will invalidate any warranty
When the following occurs, unplug the unit from the power socket and contact
the supplier to arrange for repair.
A: – When the power cord or plug is damaged or worn
B: – If any kind of liquid is spilt into the machine
C: – If the body of the unit is cracked or broken
D:D: – If there is a signi cant change in the performance and cleaning or
replacing the lters does not cure the problem It is recommended that the UV
germicidal lamp should be regularly replaced (approx 5000 hours),
Clean the primary, medium efficiency lter once every six months and the HEPA
lter as required.