cureuv com 511128 Advanced UVC System with Motion Sensor and Remote
Control
Product Information
Specifications :
- SKU: 511128
- Brand: CureUV.com
- Manufacturer: SPDI Inc.
- Address: 2801 Rosselle Street, Jacksonville, FL 32205
- Contact: Tel – 800-977-7292, E-Mail – sales@cureUV.com
Product Usage Instructions
- Unpack the UVC Linear device carefully.
- Ensure the device is placed on a flat, stable surface.
- Plug in the device to a power source using the provided cable.
- Turn on the UVC Linear by following the instructions in the user manual.
- Aim the UVC light towards the area you wish to sanitize, ensuring no people or pets are present in the vicinity.
- Leave the UVC Linear device on for the recommended duration for effective sanitization.
- After use, turn off the device and unplug it from the power source.
- Store the UVC Linear in a safe place away from children and pets.
Frequently Asked Questions (FAQ):
-
Q: How often should I use the UVC Linear for sanitization?
A: The frequency of use depends on your specific needs. It is recommended to use the UVC Linear for sanitization as per your requirement, keeping in mind safety precautions. -
Q: Can the UVC Linear be used on all surfaces?
A: While UVC light is effective for sanitization, it is essential to check the compatibility of surfaces with UVC exposure. Some materials may be sensitive to UVC light. -
Q: Is it safe to look directly at the UVC light?
A: No, it is not safe to look directly at UVC light as it can be harmful to your eyes and skin. Always ensure proper precautions are taken while using the UVC Linear.
UVC LINEAR USER MANUAL
Ultraviolet Sterilization and Purification Lamp
Product Features and Specification model:
Built-in dual protection of microwave induction and PIR induction, which can
automatically turn off the UVC lamp when someone passes by. A variety of
interfaces are reserved for connection to the mains, and double insulated
cables can be used, or metal hoses can be used for wiring. High-strength
barbed wire protection design. It can prevent the UVC lamp tube from being
stably removed from the lamp, and also prevent the lamp tube from being
damaged when the lamp is moved to install, and prevent the UVC lamp tube from
being crushed by foreign objects.
U12 UVC LAMP SUGGESTED AREA AND TIME
Instructions
Manual of remote controller:
Manual of remote controller (choose the model before using) Two models:
standard model and automatic model, switch button under back battery.
-
Standard model:
When the module is triggered to turn off the light, it will not start automatically after detecting no one there. If you need to turn on the light, you need to press the ON button. -
Automatic model:
When the movement detected, lamp turn off; then lamp will turn on in 2 minutes when no movement detected; and it will go for repeated process like this if any movements detected.
CureUV.com 2801 Rosselle Street Jacksonville, FL 32205
Tel: 800-977-7292 E-Mail:
sales@cureUV.com
Manual of remote controller (please select model before using)
- Two models: standard model and automatic model, swift button under back battery.
- Standard model: the lamp not automatic on after 2 minutes without detection.
- Automatic model: the lamp automatic on after 2 minutes without detection.
- Power the lamp with voltage within the range on lamp, otherwise the lamp will be broken.
- Press the “lock” button to start. choose any button, it will take around 18 seconds to turn on after the sounds stop.
- The continuous sounds to warn people out of the disinfection area asap.
- Five different disinfection time setting (ON/30MIN/60MIN/90MIN/120MIN) ; “ON” means no time limited.
- If you want to cancel the time setting, press OFF. Each time the lamp sounds around 18 seconds then on without detection.
- Our remote controller is well paired with lamp one on one, considering about too sensitive signal.
- You need press “120MIN” button with in 5 seconds when the lamp on to match another lamp and then control.
Note: Other buttons are out of function, if the “lock button” not pressed
Prompt tone description:
The main unit prompts intermittent or continuous sound, and the indicator
light flashes to indicate that the UVC lamp is about to turn on. Warn people
or animals to leave the illuminated area as soon as possible to prevent injury
from UVC exposure.
Sensor description:
Sensor detection: 1 Microwave + 1 PIR sensor, automatically turn on once
the light switch on. The light will be turn off automatically when unintended
entry detected.
Battery manual instruction : Take off the tape on battery (model: CR2032
3V) for first time use, press any key, there is light, means OK for the remote
controller.
CAUTIOUS
- Press the “LOCK” button before operating other function buttons.
- After the UVC lamp is working normally, the lamp is turned off by the artificial trigger sensor module. If there is no abnormal detection within 2 minutes, the lamp will automatically turn on and work normally. The suspended time will not count in the timer
- The signal of the remote control is a non-linear wave signal, and might be work through a wall.
Technical Specifications
- Operating temperature:-10 ~ + 35°C,
- Operating environment humidity: <80% ,
- Storage temperature: -20 ~ + 60°C ,
- Sensor detection range: 360 degrees,
- Sensor detection distance: 0-5 meter,
- Sensor type: 1 Microwave + 1 PIR sensor,
- Remote control distance: 10 meter.
- Principles and Sterilization factor Sterilization factor: Ultraviolet 253.7nm
- The principle of sterilization: Use the C-band ultraviolet light emitted by the ultraviolet lamp to destroy the bacteria and DNA of bacteria for sterilization.
- Applications: The product is suitable for disinfection of indoor places such as medical institutions, schools, offices, commercial places, product industry, pharmaceutical industry and household use.
UVC Operation instructions for lamp tube installation
Parts functions and Parameters Cautious
- Please make sure the input voltage within the range on the lamp.
- Before installation, remove the bubble cotton on the tube otherwise the lamp will not have disinfection function
Wiring instruction
Installation diagram (wall mount and hanging)
Different installation
Recommended installation height: 2.3-5 m
Precautions for use
- Only professional maintenance is allowed, so as not to damage the precision electronic components.
- If the ambient temperature is too high (above 35 °C), the PIR sensing distance will be shortened (It is normal). At the same time, there is a possibility that the lamp is turned off by mistake, do avoid installing the lamp in direct air flow location (such as: cold / hot water outlet, exhaust fan, near the electric furnace, etc.). The sensor head cannot be blocked or covered otherwise there will be a risk of PIR sensor failure.
- The microwave sensor may turn off the light by mistake in heavy rain. The lights will be turned off by mistake when there is a sewer pipe flowing around. Poor sensing of objects moving at a uniform speed. There should be no metal shielding in front of the microwave sensor. There must be no vibration at the installation location, which will turn off the lights by mistake.
- Keep a distance of 1 meter at least between each light, otherwise the microwave sensor might fail to detect
- The wireless remote works when there is wall and multiple lights be controlled by one remote at the same time, which is normal.
Troubleshooting
WARNING
UV-C emitted from this product Avoid eye and skin exposure to unshielded
product. Follow installation instructions and user manual.
Warning :
- UVC is harmful to human body or animals, please do not expose directly to the skin and eyes, please leave immediately once the lighting buzzing.
- If the body is slightly uncomfortable, please leave the UVC light source immediately.
- In severe cases, headache, dizziness, increased body temperature, eye irritation, or decreased vision, Skin irritation, itching, swelling, etc. please consult your doctor immediately.
Additional Note:
- The product cannot be used for lighting purposes.
- The product can only be used for the sterilization of the object surface and air, can not be used for the sterilization of the surface of the human body. During the use of the product, the surface of UV sterilization lamp should be kept clean. If there is dust or oil on the lamp surface, please wipe it in time. It is recommended to wipe it with a damp cloth and then dry it. Never rinse it with water.
- When you use the product for indoor air sterilization, please close the doors and windows to keep the room clean and dry, and reduce dust and moisture. If the room temperature is lower than -10 degrees or higher than 35 degrees, it is not recommended for use. Please open the doors and windows for 10 minutes after sterilization.
- When using this product to sterilize the surface of objects, keep a distance of not more than 1.2 meter from the irradiation surface. The closer to the lamp, the better the sterilization effect. The best sterilization location is near the lamp tube. If there are paintings, plants, utensils, and other ultraviolet sensitive items in the room, they should be covered.
- Long time to irradiate UVC to the object, irreversible damage will occur to the object that is not resistant to ultraviolet rays, and the object will become chemical phenomenon, If the surface of the white object is exposed, the illumination will change the objects color that will appear in pale. Plastic items that are not UV resistant will become brittle.
- After sterilization, please put away the product and the remote control to avoid accidental light on and accidental injury.
- If the UV sterilization lamp is accidentally broken, it should be ventilated in time and wear gloves or clean up with a mercury vacuum cleaner or with other suitable means that avoids generating dust and mercury vapor. Do not use a standard vacuum cleaner.
- After handling broken lamps, remove protective clothing and thoroughly wash hands before eating, smoking, or using toilet facilities
Warranty
Within 1 year after the purchase date, you can get free warranty service if the defective caused by the manufacturing process, technology, and components. The free service cannot be obtained under the following circumstances:
- Beyond the effective service or free maintenance period.
- Man-made damage caused by improper use. For example, improper installation, use not in accordance with the instructions, damage caused by incorrect use, etc. Damage caused by transportation or other accidents. Other damage caused by force majeure (such as natural disaster, abnormal voltage, etc.)
- The normal product aging, wearing, etc., which does not affect the normal use of the product. Other non-product design, technology, manufacturing, quality and other problems cause failure and damage.
This document is copyright@July 18, 2024 SPDI, Inc. All rights reserved. This
document is provided for information purposes only. Contents are subject to
change without notice. It is not warranted to be error-free. Nor subject to
any other warranties or conditions including implied warranties and conditions
of merchantability or fitness for a particular purpose.
Phone: 800-977-7292 Address: 2801
Rosselle St Jacksonville, FL 32205 Web store:
www.CureUV.com
References
- UV Curing Lamps, UV-C Sterilizer Light Bulbs, Ultraviolet Cure Systems
- UV Curing Lamps, UV-C Sterilizer Light Bulbs, Ultraviolet Cure Systems
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>