cureuv GermAwayUV High Occupancy 150 Watt Wall Mountable Air Purifier and Sanitizer Installation Guide

June 8, 2024
cureuv

cureuv GermAwayUV High Occupancy 150 Watt Wall Mountable Air Purifier and

Sanitizer

WARRANTY

The unit is covered for 12 months.

  • The following are not covered by the Warranty
  • Accidental or deliberate damage caused by human factors.
  • Damage caused by repairs carried out by unauthorized persons.
  • Normal wear and tear during use.

Filter screen
Damage was caused due to failure to follow the correct instructions for installation and use.

Please read the manual before operation.

  • The use of this machine must be in accordance with the rules prescribed by the operation
  • Do not use in areas where there is a risk of flammable or an explosive atmosphere
  • Best results are achieved when doors and windows of the room a reclosed
  • The unit must not be connected to the power supply during installation, cleaning or maintenance
  • Do not cover or block the air inlet or outlet of the machine
  • Do not insert anything into the gril Is of the machine, this could result in fire or electric shock,
  • Do not spill any liquid on the machine.
  • The power must be disconnected before opening the covers to avoid being exposed to WC.
  • The power supply must be a single phase with a ground connection

Installation of the wall bracket

  1. Pick a location close to a power outlet and with adequate space around the unit.
  2. If the wall is suitable, use the supplied screws, if not, be sure to attach the brae ket securely using an appropriate fixing method.
  3. Hang the machine onto the bracket, ensuring it is attached properly.
  4. Lift the front cover, remove the filters by lifting their bottom edge and pulling them towards you slightly then, sliding them down.
  5. Check the UV bulbs are all seated correctly in their sockets and remove the transit twist ties.
  6. Replace the filters by sliding them up and lifting the bottom edge back behind the clips. Close the cover.
  7. Plug in the power lead.

FOR THE BEST RESULTS
Close the doors and windows of the room that the unit is in.

Plug in the power and the power Right will illuminate. This machine utilizes an ultraviolet germicidal lamp and titanium dioxide photocatalytic filter screen, it can be safely operated in an occupied area.

Remote control instructions

  • To turn the unit on or off, press the red “ON/OFF” button. The clock will show in the display.
  • To set the Time (All times are 24-hour clock), Press the”CLOCK” button and then use the up and down keys to set the digit, press the “CLOCK” button to move to the next digit, and repeat until the correct time is displayed.
  • Press the “PURIFICATION” key to start a filter-only run, and press it again to turn the unit off.
  • Pressing the “DISINFECTION” key will turn on the UVC for sterilization, press it again to turn the unit off
  • The “SWING FLAP” key will start or stop the air deflection flap.
  • To alter the airflow, press “WINO SPEED” and the up or down keys.
  • When the unit is running, you can set It to turn off automatically by pressing the “TIME SETTING” key followed by the up or down key this set a run time, press the “TIME Sffii NG” key again and the unit will tum off after the desired time has elapsed.
  • Pressing the “CUMULATIVE TIME” key will show you the total time runtime for the unit.

To program a scheduled timer

  1. Press the “SETTING button.
  2. For the Start time. Use the up and down keys to set the first digit, press”TIME SETTINGS to move to the next digit, and repeat until the correct time is shown.
  3. Press the “Setting button again.
  4. For the end time, Use the up and down keys to set the first digit, press “TIME SETTINGS to move to the next digit, and repeat until the correct time is shown.
  5. Press the “Setting button again.

The unit will turn on at the first time set, and off at the second time set. Up to 6 times can be set throughout the day.

Performance and main features

The machine uses an ultraviolet germicidal lamp along with a filter screen and can be used in occupied areas

Working Conditions
  1. Power supply: ACL 1 0V±22V; Power frequency: 50HZ± 1 HZ
  2. Environmental parameters:
    • Ambient temperature range: -5C~40C
    • Relative humidity range: 65%~85%:
    • Atmospheric pressure range: 800hpa~ 1060hpa
  3. Safety classification: equipment of class II type B.

Suggested applications

These units can be used for air disinfection in many locations including homes, hospitals, pharmaceutical plants, food plants, hotels, kinder­gartens, schools, food and catering, public places of entertainment, offices, and canteens.

  • Main bactericidal factors and strength.
  • The main bactericidal method of this machine is from ultraviolet radiation, the intensity of each
  • UV germicidal lamp >200w/cm2 (1 m from the machine).
  • Targeted microbiological category.
  • Common airborne bacteria.

The main structure of the product and working principles

incoming air———> Filter screen——-> Fan——–> UVC Lamps——> Clean air after disinfection 110 volts AC———-> Control system———–> Negative lons——————-/\.

Main technical parameters and specifications

  • Each UV sterilization lamp radiation intensity >200w/cm2 (1 m from the machine)
  • Ultraviolet light out si de the machine: < 1 w/c m2 (1 cm from the machine)
  • Ozone concentration: <:0.04mg/ m3
  • Noise: <55dB

It is recommended that the UV is germicidal! the lamp should be regularly replaced (approx 5000 hours), Clean the primary, medium efficiency filter once every six months and the filter as required.

Troubleshooting

When the following occurs, please carry out the suggested fix before contacting support.

ISSUE/SUGGESTED REMEDY

Other than user-serviceable parts, filters, and bulbs, under no circumstances should the owner attempt to effect repair or replace parts. The integrity and safety of the unit could be compromised and no responsibility will be taken for any injury to a person or damage to property these actions may result in.

Other than changing the bulbs, cleaning, or replacing the filters there are no user-serviceable parts, do not attempt to dismantle the unit yourself, this will invalidate any warranty.

When the following occurs, unplug the unit from the power socket and contact the supplier to arrange for repair.

  • A: – When the power cord or plug is damaged or worn
  • B: – lf any kind of liquid is spilled into the machine
  • C: – lf the body of the unit is cracked or broken
  • D: – lf there is a significant change in the performance and cleaning or replacing the filters does not cure the problem.

It is recommended that the UV germicidal lamp should be regularly replaced (approx SCXXJ hours), Clean the primary, medium efficiency filter once every six months and the filter as required.