ZOELLER SPCP02 2400 Plug-in Pool Cover Pump Instruction Manual

June 8, 2024
Zoeller

POOL COVER PUMP

MODEL #SPCP02

ATTACH YOUR RECEIPT HERE

Serial Number       Purchase Date


ZOELLER SPCP02 - TelephoneQuestions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. – 5:00 p.m., EST, Monday – Friday.

SW1694 A

PACKAGE CONTENTS

DESCRIPTION QUANTITY
Pump 1
Base 1
Garden Hose Adaptor 1
Cap 1

ZOELLER SPCP02 - PACKAGE CONTENTS

PERFORMANCE FROM TOP OUTLET – UTILITY PUMP


ITEM NUMBER| CORD LENGTH| HP| AMPS|

GALLONS PER HOUR AT DISCHARGE HEIGHT ABOVE PUMPING LEVEL

0 FT.

| 5 FT.| 10 FT.| 15 FT.| 20 FT.
SPCP02| 25 FT.| 1/3| 3.0| 2400| 2100| 1680| 1380|

600

PERFORMANCE FROM SIDE OUTLET WITH GARDEN HOSE
AT 0FT. ABOVE PUMPING LEVEL


HOSE LENGTH

| GALLONS PER MINUTE| GALLONS PER HOUR
25 FT.| 7.7|

462

50 FT.

| 4.5| 270
75 FT.| 3.9|

234

100 FT.

| 3.0|

180

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate, or install the product.

  • NOTE: Pumps with the “UL” Mark and pumps with the “US” mark are tested to UL Standard UL778. CSA certified pumps are certified to CSA Standard C22.2 No. 108. (CUS.)

DANGER

  • FIRE/EXPLOSION HAZARD.
    Pump only clear water. Do not pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Failure to follow these warnings could result in death or serious injury and/or property damage.

  • RISK OF ELECTRIC SHOCK.
    Always disconnect power source before attempting to install, service, or maintain the pump.
    Never handle a pump with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.

WARNING

  • ELECTRICAL SHOCK ALERT.
    Before installing this product, have the electrical circuit checked by an electrician to ensure proper grounding. All electrical installations must conform to the National Electric Code and all local codes.

  • ELECTRICAL SHOCK ALERT.
    Connect this product to a properly-grounded 115 volt outlet with a ground fault circuit interrupter (GFCI) device.

  • ELECTRICAL SHOCK ALERT.
    Do not handle pump or pump motor with wet hands or when standing on a wet or damp surface or in water.

  • ELECTRICAL SHOCK ALERT.
    DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN.

  • ELECTRICAL SHOCK ALERT.
    BE CERTAIN the pump power source is disconnected before installing or servicing pump.

  • ELECTRICAL SHOCK ALERT.
    Protect electrical cord from sharp objects, hot surfaces, oil, and chemicals. Avoid kinking the cord.
    Replace or repair damaged or worn cords immediately.

  • CHEMICAL ALERT.
    This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm.

  • PERSONAL INJURY ALERT.
    Provide a means of pressure relief if the pump discharge can be shut off or obstructed. Pumps operating with a closed discharge can create hot liquid, which can cause burns.

  • PERSONAL INJURY ALERT.
    This pump is equipped with an automatic thermal overload and can restart without warning.

  • PERSONAL INJURY ALERT.
    Always use handle to lift pump. Never use power cord to lift pump. To avoid skin burns, unplug and allow the pump to cool after periods of extended use.

CAUTION

  • PERSONAL INJURY OR PRODUCT DAMAGE MAY RESULT.
    Check to be sure your power source is capable of handling the voltage requirements of the motor, as indicated on the pump name plate.

  • PRODUCT DAMAGE MAY RESULT.
    These pumps are not designed or intended to be used to handle sewage or effluent.

  • PRODUCT DAMAGE MAY RESULT.
    This pump has been evaluated for use with WATER only.

  • PRODUCT DAMAGE MAY RESULT.
    Maximum continuous operating water temperature for standard model pumps must not exceed 104°F (40°C).

  • PROPERTY DAMAGE MAY RESULT.
    Do not use where fish are present. Oil in motor can kill fish.

  • PERSONAL INJURY RESULT.
    Secure the discharge hose before starting the pump. A loose discharge hose may whip, which can cause personal injury and/or property damage.

  • PRODUCT DAMAGE MAY RESULT.
    Keep the pump, base, and inlet screen free of debris and foreign objects.

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list. If any part is missing or damaged, do not attempt to assemble the product.

Estimated Assembly Time: 5 minutes

No Tools Required for Assembly.

For best performance, use discharge hose of 50 ft. or less. If the discharge runs up hill, or is extra long, use larger diameter discharge hose or rigid pipe.

NOTE: Large diameter, short discharge hoses or pipe will provide better water flow rates than small diameter, long discharge hoses or pipe.

POOL COVER PUMP INSTALLATION INSTRUCTIONS

1. Install the snap-on strainer by lining up the pump base to match the strainer. Push down gently until it latches.

ZOELLER SPCP02 - POOL COVER PUMP INSTALLATION 1

2. Attach garden hose adapter to the top pump discharge. DO NOT OVER-TIGHTEN THE HOSE ADAPTER. Finger tight plus 1/4 to 1/2 turn should be sufficient.

Ensure cap is installed on top discharge.

3. For best stability, attach garden hose to lower discharge. 1-1/4″ top discharge may be used with proper support of discharge line and pump.

If using garden hose (not included), thread the female end of the garden hose into the male end near the bottom of the pump. DO NOT OVER-TIGHTEN THE HOSE. Finger tight plus 1/4 to 1/2 turn should be sufficient.

For best performance, unwind the hose before starting the pump.

ZOELLER SPCP02 - POOL COVER PUMP INSTALLATION 3

4. Place pump in an upright position on the pool cover where water will collect. Do not suspend pump by the discharge hose or power cord.

Be sure pump is not sitting in mud, sand, or debris.

ZOELLER SPCP02 - POOL COVER PUMP INSTALLATION 4

5. Plug the pump into a properly grounded, ground fault circuit interruptor (GFCI) 115 V outlet. For safety, the pump should always be electrically grounded to a suitable electrical ground, such as a grounded water pipe, properly grounded metallic raceway, or ground wire system.

ZOELLER SPCP02 - POOL COVER PUMP INSTALLATION 5

UTILITY PUMP INSTALLATION INSTRUCTIONS

1. To enable pump to fit into smaller spaces remove snap on base from pump by pulling the tab outward. This allows the pump to lift out of the base.

ZOELLER SPCP02 - UTILITY PUMP INSTALLATION 1

2. Attach garden hose adapter to the pump discharge and then connect garden hose to adapter. DO NOT OVER-TIGHTEN THE GARDEN HOSE OR HOSE ADAPTER. Finger tight plus 1/4 to 1/2 turn should be sufficient.

Attach cap to bottom outlet.

3. Place pump in the water on a hard surface. Water must be at least 1-3/4-in deep in order for pump to operate. Avoid placing pump directly on sand, dirt, or mud.

ZOELLER SPCP02 - UTILITY PUMP INSTALLATION 3

  1. Hard Surface

4. Plug pump into a properly grounded, ground fault circuit interrupter (GFCI) 115V AC power outlet.

ZOELLER SPCP02 - UTILITY PUMP INSTALLATION 4

  1. GFCI Outlet
OPERATION

1. Water must be a minimum of 1-3/4-in deep for pump to operate.

The pump will run for 15 seconds after it is plugged in. If water is being pumped during this 15 seconds, the pump will continue operating until water level drops to 1/8-in. At that time, the pump will shut off.

After the pump shuts off, it will automatically turn back on every three minutes for 15 seconds and then turn back off if it is not pumping water. To re-start the pump sooner, unplug the pump for a few seconds and plug it back in.

NOTE: This pump does not contain a water level sensor but will automatically shut itself off when water level drops to 1/8-in. A built-in timer turns the pump back on after 3 minutes and it will continue pumping as long as water is present.

ZOELLER SPCP02 - OPERATION 1

  1. 1-3/4-in minimum to operate

2. To prevent unnecessary wear, unplug the pump from the power output when not in use.

CAUTION: Extended usage of the pump in a partially submerged or non-submerged situation may cause the pump to overheat due to lack of heat dissipation from the water. If this occurs, the pump will shut itself off until the motor cools to its normal temperature. Repeated overheating may cause damage to the pump.

ZOELLER SPCP02 - OPERATION 2

  1. Unplug Pump
  2. Low Water
CARE AND MAINTENANCE

The motor housing of pump is completely sealed and requires no service. Disassembly of the motor housing or alteration of the power cord voids all warranty.

1. Periodically unplug pump to inspect the inlet and remove any debris. Make sure your hands are dry and that you are not standing in water.

ZOELLER SPCP02 - CARE AND MAINTENANCE 1

  1. Unplug pump
  2. Remove debris

2. If pump clogs, unplug the pump from the power supply. Attach one end of a garden hose to a spigot and the other end to pump discharge. Turn on the spigot to run water through pump to clean it out.

ZOELLER SPCP02 - CARE AND MAINTENANCE 2

3. If the pump becomes clogged, remove the screen and clean out the area.

Debris in the intake should be routinely removed from the bottom of the pump to prevent damage to the pump, which will void the warranty.

ZOELLER SPCP02 - CARE AND MAINTENANCE 3

  1. Remove Screen
TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
Pump runs, but no water is discharged. 1. Hose kinked. 1. Straighten hose.
2. Defective pump. 2. Replace pump.
3. Discharge height too great. 3. Reduce discharge height.
4. Clogged inlet. 4. Clean inlet.
5. Low line voltage. 5. Call power company.
6. Impeller is clogged. 6. Unplug pump and clean out impeller.
7. Garden hose diameter is too small or too long. 7. Use larger diameter

garden hose or 1 in. flexible pipe.
Motor runs too hot.| 1. Voltage incorrect.| 1. Connect to 115 volt GFCI outlet.
2. Restricted discharge hose.| 2. Increase hose diameter to 3/4-in.
3. Pump damaged.| 3. Replace pump.
4. Plugged or kinked discharge.| 4. Clean and straighten hose.
Flow rate is low.| 1. Hose kinked.| 1. Straighten hose.
2. Clogged impeller.| 2. Clear obstruction.
3. Excessive length of hose.| 3. Reduce length of outlet hose.
Pump will not run.| 1. No power.| 1. Verify that unit is plugged into 115 volt GFCI outlet.
2. Motor overheated.| 2. Motor has automatic thermal protector. Wait 15 minutes for motor to cool.
3. Blown fuse or circuit breaker.| 3. Reset the circuit breaker or replace fuse with a fuse of the proper size.
4. Low line voltage.| 4. Call power company.
5. Defective motor.| 5. Replace pump.
6. Water level is too low.| 6. Allow the water level to rise to 1-3/4 in. or more.
7. GFCI needs to be reset.| 7. Press reset button on GFCI outlet.

WARRANTY

This product is warranted for two years from the date of purchase. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves defective due to defective materials or workmanship. This warranty does not cover replacement parts for failure due to normal wear and tear. To obtain warranty service, contact the dealer from whom the product was purchased. The manufacturer retains the sole right and option to determine whether to repair or replace defective equipment, parts or components. Damage due to conditions beyond the control of the manufacturer is not covered by this warranty.

THIS WARRANTY WILL NOT APPLY:
(a) To defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided;
(b) to failures resulting from abuse, accident or negligence or use of inappropriate chemicals or additives in the water;
(c) to normal maintenance services and the parts used in connection with such service;
(d) to units which are not installed in accordance with normal applicable local codes, ordinances and good trade practices; and
(e) if the unit is used for purposes other than for what it was designed and manufactured.

RETURN OF WARRANTED COMPONENTS:
Any item to be repaired or replaced under this warranty must be returned to the manufacturer at Kendallville, Indiana or such other place as the manufacturer may designate, freight prepaid.

THE WARRANTY PROVIDED HEREIN IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND MAY NOT BE EXTENDED OR MODIFIED BY ANYONE. ANY IMPLIED WARRANTIES SHALL BE LIMITED TO THE PERIOD OF THE LIMITED WARRANTY AND THEREAFTER ALL SUCH IMPLIED WARRANTIES ARE DISCLAIMED AND EXCLUDED. THE MANUFACTURER SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, SUCH AS, BUT NOT LIMITED TO DAMAGE TO, OR LOSS OF, OTHER PROPERTY OR EQUIPMENT, LOSS OF PROFITS, INCONVENIENCE, OR OTHER INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY TYPE OR NATURE. THE LIABILITY OF THE MANUFACTURER SHALL NOT EXCEED THE PRICE OF THE PRODUCT UPON WHICH SUCH LIABILITY IS BASED.

This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow limitations on duration of implied warranties or exclusion of incidental or consequential damages, so the above limitations may not apply to you.

In those instances where damages are incurred as a result of an alleged pump failure, the Homeowner must retain possession of the pump for investigation purposes.

Printed in Taiwan

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Zoeller User Manuals

Related Manuals