WOLF 810991 500 CFM Internal Blower Installation Guide
- June 8, 2024
- Wolf
Table of Contents
810991 500 CFM Internal Blower
Installation Guide
810991 500 CFM Internal Blower
Remove the block off plate from the top of the hood.When
a vertical discharge has been chosen, discard the damper mounting plate from
the back of the hood and install the block off plate from the previous step in
its place.Next, remove the knock-out on the blower plate.
NOTE: DO NOT remove the knock-out on the blower plate if a horizontal
discharge is desired.Secure the blower plate inside the hood with 4
lock nuts.If a vertical discharge has been chosen, the
included air diverter must be installed.
NOTE: If installed correctly, the air diverter will protrude about 1/8”
above the blower plate. Remove the filter support from the upper filter
channel located inside the hood.Remove the cover from the blower assembly. Remove
the impeller by pulling it out gently. Install 4 screws into the location
shown below. Do not tighten screws down fully, leave a 1/8” gap. Hang blower
unit onto blower plate (screws through the large part of the keyholes. Slide
the blower to its position (screws in the small part of the keyhole). Tighten
the screws.Secure the blower by installing 2 more screws
into the locations shown below. Reinstall impeller and cover. Also, reinstall
filter support. Plug ventilator’s power cord into receptacle inside the hood.
Align damper screw holes with holes in hood to properly position
the damper on hood. Using two (2) standard ½” screws (1 per side), secure the
adapter to the top (or back) of the hood). Seal the adapter to the hood using
duct tape.