NOVALUX 90884 18W LED U-Bend T8 LED Tube Instruction Manual

June 4, 2024
NOVALUX

NOVALUX 90884 18W LED U-Bend T8 LED Tube

PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION. Please read the instructions before you install and use the linear tube(s).

THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED.

WARNINGS

  • WARNINGS – Risk of fire or electric shock. The electrical rating of these products are 120-277Vac, the installer must determine whether they have 120-277Vac at the luminaire before installation.
  • WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaire electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician.
  • WARNING – Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
  • WARNING – To avoid potential fire or shock hazards, do not use this retrofit kit in luminaires employing shunted bi-pin lamp holders. Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-Start ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the form of a statement pertaining to the ballast itself, or may be combined with the marking for the lamps with which the ballast is intended to be used, for example, F40T12/IS. For more information, contact the LED luminaire retrofit kit manufacturer.
  • WARNING – To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead, installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.

THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY AUTHORITIES HAVING THE JURISDICTION. THE PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE AND APPROPRIATE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS.

  • Suitable for damp locations.
  • This device is not intended for use with emergency exit fixtures or battery backups.
  • Not for use with dimmers.

INSTALL INSTRUCTIONS

DIRECT REPLACEMENT (Plug & Go™) INSTRUCTIONS

WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

  1. Turn off power before installation.
  2. Remove diffuser (if provided).
  3. Remove existing fluorescent lamp(s) from luminaire.
  4. Install LED T8 U-Lamp replacement.
  5. Attach the diffuser and turn on the power switch to the fixture.NOVALUX-90884-18W-LED-U-Bend-T8-LED-Tube-fig-1
DIRECT WIRE (Bypass) INSTRUCTIONS
  • STEP 1 – Turn off power before installation.
  • STEP 2 – Remove; diffuser (if provided), existing fluorescent lamp(s), ballast and starter (if present) from the fixture. (Fig. 1 – Electric Ballast and Fig. 2 – Magnetic Ballast)

FIG. 1 – ELECTRIC BALLASTNOVALUX-90884-18W-LED-U-Bend-T8-LED-Tube-
fig-2

WARNING DISCONNECT POWER BEFORE INSTALLING OR SERVICING.

FIG. 2 – MAGNETIC BALLASTNOVALUX-90884-18W-LED-U-Bend-T8-LED-Tube-
fig-3

STEP 3 – Rewire fixture to be Single Ended or Double Ended

  • Single-Ended: Lead 1 connects to L; Lead 2 connects to N, Leads 1 and 2 at the end of the lamp holder with LN.
  • Double-Ended: Leads 1 or 2 connect to L; Leads 3 or 4 connect to N.NOVALUX-90884-18W-LED-U-Bend-T8-LED-Tube-fig-4

CAUTION: USE ONLY NON-SHUNTED LAMP HOLDERS FOR SINGLE-ENDED WIRING INSTALLATIONS
Do not perform Single-Ended wiring installation of the product in a fixture with shunted lamp holders (found in all fixtures using instant start ballasts). If the existing lamp holders are shunted, and Single-Ended wiring is desired, remove and replace them with non-shunted lamp holders (or remove the external shunt if applicable). Make new connections directly to lampholder terminals as shown in Fig. A.

Fig. A – TYPICAL NON-SHUNTED LAMPHOLDER
If the sockets are non-shunted, they can be wired for either single end and double end.

Fig. B – TYPICAL SHUNTED lamp holders
If the sockets are shunted, they can only be wired for the double end.

  • STEP 4 – After the wiring modification is complete, place the CAUTION label included with this kit in a location where it is visible to installers. The fixture has been modified to operate LED Lamps and can no longer operate fluorescent lamps.
  • STEP 5 – Install LED U-Lamp (Fig. C) and reinstall the diffuser (if removed).
  • STEP 6 – Restore power, installation is complete.