50076346 Basic Board Mount Pressure Sensors
INSTALLATION INSTRUCTIONS FOR THE
BASIC BOARD MOUNT PRESSURE SENSORS
50076346
Issue H
TBP Series: Compensated/Unamplified 60 mbar to 10 bar | 6 kPa to 1 MPa |1 psi to 150 psi, Millivolt Analog Output
NBP Series: Uncompensated/Unamplified 60 mbar to 10 bar | 1 psi to 150 psi, Millivolt Analog Output
GENERAL INFORMATION
Honeywell’s Basic Board Mount Pressure Sensors, TBP Series and NBP Series, are
designed for food grade and non-food grade potential medical and industrial
applications. These unamplified, piezoresistive silicon pressure sensors
provide a ratiometric output and are either temperature compensated (TBP
Series) or uncompensated (NBP Series).
CAUTION
MISUSE OF GEL COATING OPTION
· No gel coating in media path: The input port is limited to non-corrosive,
non-ionic media such as dry air and gases and should not be exposed to
condensation. The gases are limited to media which are compatible with the
following wetted materials of construction: high temperature polyamide,
silicone, alumina ceramic, silicon, gold, and glass.
· Silicone gel coating in media path: The gel coated sensors use the same
materials in the wetted media path but are protected from condensation by a
silicone-based gel coating. The gel coating option allows use in applications
where condensation can occur.
Failure to comply with these instructions may result in product damage.
SOLDERING See soldering times and temperatures in Table 1.
CAUTION
IMPROPER CLEANING
· Ensure cleaning fluids, such as appropriate alcohols or fluorinated
solvents, are used based on the type of contaminants to be removed.
· Do not immerse the sensor.
Failure to comply with these instructions may result in product damage.
TABLE 2. ABSOLUTE MAXIMUM RATINGS1
CHARACTERISTIC Supply voltage (Vsupply)2 Storage temperature
MIN.
MAX.
-12.0
12.0
-40 [-40] 125 [257]
UNIT Vdc
°C [°F]
Soldering time and temperature:
lead solder temperature (DIP)
peak reflow temperature (SMT, Leadless SMT)
4 s max. at 250°C [482°F] 15 s max. at 250°C [482°F]
1Absolute maximum ratings are the extreme limits the device will withstand without damage. 2Incorrect application of supply voltage or ground to the wrong pin may cause electrical failure.
TABLE 1. OPERATING SPECIFICATIONS
CHARACTERISTIC
MIN.
TYP.
MAX.
UNIT
TBP SERIES
Supply voltage (Vsupply)1, 2 Supply current (at 5.0 Vdc supply) Operating temperature range3 Compensated temperature range4 Output resistance
1.5 — -40 [-40] 0 [32] —
5.0
12.0
Vdc
0.6
1
mA
—
125 [257]
°C [°F]
—
85 [185]
°C [°F]
2.5
—
kOhm
NBP SERIES
Supply voltage (Vsupply)1, 2 Supply current (at 5.0 Vdc supply)
1.8
5.0
12.0
Vdc
—
1.5
2.5
mA
Specified temperature range5
-40 [-40]
—
125 [257]
°C [°F]
Accuracy6
—
—
±0.25
%FSS BFSL7
Input resistance
2.4
3.0
5.5
kOhm
Thermal effect on resistance (TER)8
1200
—
3200
ppm/°C
1Ratiometricity of the sensor (the ability of the device output to scale to
the supply voltage) is achieved within the specified operating voltage.
2Incorrect application of supply voltage or ground to the wrong pin may cause
electrical failure. 3Operating temperature range: The temperature range over
which the sensor produces an output proportional to pressure. 4Compensated
temperature range: The temperature range over which the sensor produces an
output proportional to pressure within the specified performance limits.
5Specified temperature range: The temperature range over which the sensor will
produce an output proportional to pressure within the specified performance
limits. 6Accuracy: The maximum deviation in output from a Best Fit Straight
Line (BFSL) fitted to the output measured over the pressure range at 25°C
[77°F]. Includes all errors due to pressure non-
linearity, pressure hysteresis, and non-repeatability. 7Full Scale Span (FSS):
The algebraic difference between the output signal measured at the maximum and
minimum limits of the pressure range. (See Figure 2 for pressure ranges.) 8TER
(Thermal Effect on Resistance): The deviation in input resistance due to
change in temperature over the specified temperature range, relative to input
resistance measured at 25°C [77°F].
Honeywell
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
TABLE 2. PRESSURE REFERENCE TYPES
PRESSURE TYPE Absolute Differential Gage
DESCRIPTION
Output is proportional to the difference between applied pressure and a built-
in reference to vacuum. Reference pressure is absolute zero pressure (full
vacuum).
Output is proportional to the difference between the pressures applied to each
port (Port 1 – Port 2).
Output is proportional to the difference between applied pressure and
atmospheric (ambient) pressure. Reference pressure is atmospheric pressure.
TABLE 3. ENVIRONMENTAL SPECIFICATIONS
CHARACTERISTIC
Humidity: all external surfaces internal surfaces of silicone gel coating
option internal surfaces of no gel coating option
Vibration
PARAMETER
0 %RH to 95 %RH, non-condensing 0 %RH to 100 %RH, condensing 0 %RH to 95 %RH,
non-condensing MIL-STD-202G, Method 204D, Condition B (15 g, 10 Hz to 2 kHz)
Shock
MIL-STD-202G, Method 213B, Condition C (100 g, 6 ms duration)
Life1
1 million pressure cycles min.
ESD
MIL-STD-883 Method 3015.7
Solder reflow
J-STD-020E, MSL 1, unlimited storage life
Certification (silicone gel coating option: Port 1 only) NSF- 169, BPA Free, LFGB 1Life may vary depending on specific application in which the sensor is utilized.
TABLE 4. WETTED MATERIALS1
COMPONENT
PRESSURE PORT 1 (P1)
NO GEL COATING IN MEDIA PATH
SILICONE GEL COATING IN MEDIA PATH (FOOD GRADE)
Ports and covers
high temperature polyamide
Substrate
alumina ceramic
—
Adhesives
epoxy, silicone
epoxy, silicone gel
Electronic components silicon, gold, glass, solder, aluminum 1Contact Honeywell Customer Service for detailed material information.
304SST
PPRESSURE PORT 2 (P2)
alumina ceramic epoxy, silicone silicon
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 2
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
Pressure Range Order Code (see Figure 1) Pmin. Pmax. Unit Port 1 Port 2 Port 1
Port 2
Common Mode Pressure3 Pressure Accuracy (%FSS)4
Offset (mV/V)5 Long-Term Stability 1000 hr
at 25°C (%FSS) Thermal Hysteresis No Gel Option (%FSS)9 Thermal Hysteresis
Silicone Gel Option (%FSS)9
TABLE 5. TBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 60 MBAR TO 10 BAR
Pressure Range
OverPressure1
Burst Pressure2
Full Scale Span (mV/V)6
Thermal Ef- Thermal Effect
fect on Offset on Span
(%FSS)7
(%FSS)8
10ºC 0ºC 10ºC 0ºC
Min. Nom. Max. to
to
to
to
50ºC 85ºC 50ºC 85ºC
GAGE
060MG 0 60 mbar 872 — 1370 — — ±0.20 ±0.075 1.23 1.30 1.40 ±1.15 ±2.35 ±1.00 ±2.00 ±0.45 ±0.40 ±0.60
100MG 0 100 mbar 872 — 1370 — — ±0.20 ±0.075 2.06 2.20 2.33 ±0.70 ±1.40 ±1.00 ±2.00 ±0.30 ±0.25 ±0.35
160MG 0 160 mbar 2000 — 4000 — — ±0.15 ±0.12 2.18 2.30 2.46 ±1.65 ±3.30 ±0.75 ±2.00 ±0.55 ±0.35 ±0.55
250MG 0 250 mbar 2000 — 4000 — — ±0.15 ±0.12 3.41 3.65 3.85 ±1.05 ±2.10 ±0.75 ±2.00 ±0.35 ±0.20 ±0.35
400MG 0 400 mbar 2000 — 4000 — — ±0.15 ±0.12 5.45 5.80 6.15 ±0.65 ±1.30 ±0.75 ±2.00 ±0.20 ±0.15 ±0.20
600MG 0 600 mbar 4000 — 8000 — — ±0.15 ±0.075 2.94 3.05 3.18 ±0.85 ±1.65 ±0.50 ±1.25 ±0.40 ±0.15 ±0.35
001BG 0 1 bar 4 — 8 — — ±0.15 ±0.075 4.90 5.10 5.30 ±0.50 ±1.00 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20
1.6BG
0 1.6 bar 4 — 8 —
— ±0.15 ±0.075 7.84 8.15 8.48 ±0.30 ±0.65 ±0.50 ±1.25 ±0.15 ±0.10 ±0.15
2.5BG
0 2.5 bar 8 — 17 —
— ±0.15 ±0.075 6.10 6.35 6.59 ±0.40 ±0.80 ±0.50 ±1.50 ±0.20 ±0.10 ±0.15
004BG 0 4 bar 10 — 17 — — ±0.15 ±0.075 5.57 5.80 6.04 ±0.50 ±1.00 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20
006BG 0 6 bar 17 — 21 — — ±0.15 ±0.075 5.08 5.30 5.54 ±0.65 ±1.00 ±0.50 ±1.00 ±0.25 ±0.15 ±0.25
010BG 0 10 bar 17 — 21 — — ±0.15 ±0.075 8.47 8.85 9.22 ±0.40 ±0.60 ±0.50 ±1.00 ±0.15 ±0.10 ±0.15
DIFFERENTIAL
060MD -60 60 mbar 872 872 1370 1370 10000 ±0.20 ±0.075 2.46 2.60 2.80 ±0.60 ±1.20 ±1.00 ±2.00 ±0.25 ±0.20 ±0.30
100MD -100 100 mbar 872 872 1370 1370 10000 ±0.20 ±0.075 4.12 4.40 4.66 ±0.35 ±0.70 ±1.00 ±2.00 ±0.15 ±0.15 ±0.20
160MD -160 160 mbar 2000 2000 4000 4000 10000 ±0.15 ±0.12 4.36 4.60 4.92 ±0.85 ±1.65 ±0.75 ±2.00 ±0.30 ±0.20 ±0.30
250MD -250 250 mbar 2000 2000 4000 4000 10000 ±0.15 ±0.12 6.82 7.30 7.70 ±0.55 ±1.05 ±0.75 ±2.00 ±0.20 ±0.10 ±0.20
400MD -400 400 mbar 2000 2000 4000 4000 10000 ±0.15 ±0.12 10.90 11.60 12.30 ±0.35 ±0.65 ±0.75 ±2.00 ±0.10 ±0.10 ±0.10
600MD -600 600 mbar 4000 4000 8000 8000 10000 ±0.15 ±0.075 5.88 6.10 6.36 ±0.45 ±0.85 ±0.50 ±1.25 ±0.20 ±0.10 ±0.20
001BD -1 1 bar 4 4 8 8 10 ±0.15 ±0.075 9.80 10.20 10.60 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10
1.6BD -1.6 1.6 bar 4 4 8 8 10 ±0.15 ±0.075 15.68 16.30 16.96 ±0.15 ±0.35 ±0.50 ±1.25 ±0.10 ±0.10 ±0.10
2.5BD -2.5 2.5 bar 8 8 17 17 10 ±0.15 ±0.075 12.20 12.70 13.18 ±0.20 ±0.40 ±0.50 ±1.50 ±0.10 ±0.10 ±0.10
004BD -4 4 bar 10 10 17 17 15 ±0.15 ±0.075 11.14 11.60 12.08 ±0.25 ±0.50 ±0.50
±1.25 ±0.15 ±0.10 ±0.10
1Overpressure: The maximum pressure which may safely be applied to the product
for it to remain within specifications once pressure is returned to the
operating pressure range. Exposure to higher pressures may cause permanent
damage to the product. Unless otherwise specified, this applies to all
available pressure ports at any temperature within the operating temperature
range.
2Burst pressure: The maximum pressure that may be applied to the specified
port (P1 or P2) of the product without causing escape of pressure media.
Product should not be expected to function after exposure to any pressure
beyond the burst pressure.
3Common mode pressure: The maximum pressure that can be applied simultaneously
to both ports of a differential pressure sensor without causing changes in
specified performance.
4Accuracy: The maximum deviation in output from a Best Fit Straight Line
(BFSL) fitted to the output measured over the pressure range at 25°C. Includes
all errors due to pressure non-linearity, pressure hysteresis, and non-
repeatability.
5Offset: The output signal obtained when the reference pressure is applied to
all available pressure ports. Also known as “null” or “zero”.
6Full Scale Span: The algebraic difference between the output signal measured
at the maximum and minimum limits of the pressure range (see Figure 1 for
pressure ranges).
7Thermal effect on offset: The deviation in offset due to changes in
temperature over the compensated temperature range, relative to offset
measured at 25ºC.
8Thermal effect on span: The deviation in full scale span due to changes in
temperature over the compensated temperature range, relative to full scale
span measured at 25ºC.
9Thermal hysteresis: The maximum difference between output readings when the
same temperature is reached consecutively, under the same operating
conditions, with temperature approaching from opposite directions within the
operating temperature range. Validated over the full operating temperature and
pressure ranges using a ~5ºC/ minute ramp and 30 minute dwell. Application
performance may be affected by thermal mass of end user system.
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 3
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
Pressure Range Order Code (see Figure 1) Pmin. Pmax. Unit Port 1 Port 2 Port 1
Port 2
Common Mode Pressure3 Pressure Accuracy (%FSS)4
Offset (mV/V)5 Long-Term Stability 1000 hr
at 25°C (%FSS) Thermal Hysteresis No Gel Option (%FSS)9 Thermal Hysteresis
Silicone Gel Option (%FSS)9
TABLE 6. TBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 6 KPA TO 1 MPA
Pressure Range
OverPressure1
Burst Pressure2
Full Scale Span (mV/V)6
Thermal Effect Thermal Effect
on Offset
on Span
(%FSS)7
(%FSS)8
10ºC 0ºC 10ºC 0ºC
Min. Nom. Max. to
to
to
to
50ºC 85ºC 50ºC 85ºC
GAGE
006KG 0 6 kPa 87 — 137 — — ±0.20 ±0.075 1.23 1.30 1.40 ±1.15 ±2.35 ±1.00 ±2.00
±0.45 ±0.40 ±0.60
010KG 0 10 kPa 87 — 137 — — ±0.20 ±0.075 2.06 2.20 2.33 ±0.70 ±1.40 ±1.00
±2.00 ±0.30 ±0.25 ±0.35
016KG 0 16 kPa 200 — 400 — — ±0.15 ±0.12 2.18 2.30 2.46 ±1.65 ±3.30 ±0.75
±2.00 ±0.55 ±0.35 ±0.55
025KG 0 25 kPa 200 — 400 — — ±0.15 ±0.12 3.41 3.65 3.85 ±1.05 ±2.10 ±0.75
±2.00 ±0.35 ±0.20 ±0.35
040KG 0 40 kPa 200 — 400 — — ±0.15 ±0.12 5.45 5.80 6.15 ±0.65 ±1.30 ±0.75
±2.00 ±0.20 ±0.15 ±0.20
060KG 0 60 kPa 400 — 800 — — ±0.15 ±0.075 2.94 3.05 3.18 ±0.85 ±1.65 ±0.50
±1.25 ±0.40 ±0.15 ±0.35
100KG 0 100 kPa 400 — 800 — — ±0.15 ±0.075 4.90 5.10 5.30 ±0.50 ±1.00 ±0.50
±1.25 ±0.25 ±0.10 ±0.20
160KG 0 160 kPa 400 — 800 — — ±0.15 ±0.075 7.84 8.15 8.48 ±0.30 ±0.65 ±0.50
±1.25 ±0.15 ±0.10 ±0.15
250KG 0 250 kPa 800 — 1700 — — ±0.15 ±0.075 6.10 6.35 6.59 ±0.40 ±0.80 ±0.50
±1.50 ±0.20 ±0.10 ±0.15
400KG 0 400 kPa 1000 — 1700 — — ±0.15 ±0.075 5.57 5.80 6.04 ±0.50 ±1.00 ±0.50
±1.25 ±0.25 ±0.10 ±0.20
600KG 0 600 kPa 1700 — 2100 — — ±0.15 ±0.075 5.08 5.30 5.54 ±0.65 ±1.00 ±0.50
±1.00 ±0.25 ±0.15 ±0.25
001GG 0 1 MPa 1.70 — 2.10 — — ±0.15 ±0.075 8.47 8.85 9.22 ±0.40 ±0.60 ±0.50
±1.00 ±0.15 ±0.10 ±0.15
DIFFERENTIAL
006KD -6 6 kPa 87 87 137 137 1000 ±0.20 ±0.075 2.46 2.60 2.80 ±0.60 ±1.20
±1.00 ±2.00 ±0.25 ±0.20 ±0.30
010KD -10 10 kPa 87 87 137 137 1000 ±0.20 ±0.075 4.12 4.40 4.66 ±0.35 ±0.70
±1.00 ±2.00 ±0.15 ±0.15 ±0.20
016KD -16 16 kPa 200 200 400 400 1000 ±0.15 ±0.12 4.36 4.60 4.92 ±0.85 ±1.65
±0.75 ±2.00 ±0.30 ±0.20 ±0.30
025KD -25 25 kPa 200 200 400 400 1000 ±0.15 ±0.12 6.82 7.30 7.70 ±0.55 ±1.05
±0.75 ±2.00 ±0.20 ±0.10 ±0.20
040KD -40 40 kPa 200 200 400 400 1000 ±0.15 ±0.12 10.90 11.60 12.30 ±0.35
±0.65 ±0.75 ±2.00 ±0.10 ±0.10 ±0.10
060KD -60 60 kPa 400 400 800 800 1000 ±0.15 ±0.075 5.88 6.10 6.36 ±0.45 ±0.85
±0.50 ±1.25 ±0.20 ±0.10 ±0.20
100KD -100 100 kPa 400 400 800 800 1000 ±0.15 ±0.075 9.80 10.20 10.60 ±0.25
±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10
160KD -160 160 kPa 400 400 800 800 1000 ±0.15 ±0.075 15.68 16.30 16.96 ±0.15
±0.35 ±0.50 ±1.25 ±0.10 ±0.10 ±0.10
250KD -250 250 kPa 800 800 1700 1700 1000 ±0.15 ±0.075 12.20 12.70 13.18 ±0.20
±0.40 ±0.50 ±1.50 ±0.10 ±0.10 ±0.10
400KD -400 400 kPa 1000 1000 1700 1700 1500 ±0.15 ±0.075 11.14 11.60 12.08
±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10 1Overpressure: The maximum pressure
which may safely be applied to the product for it to remain within
specifications once pressure is returned to the operating pressure range.
Exposure to higher pressures may cause permanent damage to the product. Unless
otherwise specified, this applies to all available pressure ports at any
temperature within the operating temperature range. 2Burst pressure: The
maximum pressure that may be applied to the specified port (P1 or P2) of the
product without causing escape of pressure media. Product should not be
expected to function after exposure to any pressure beyond the burst pressure.
3Common mode pressure: The maximum pressure that can be applied simultaneously
to both ports of a differential pressure sensor without causing changes in
specified performance. 4Accuracy: The maximum deviation in output from a Best
Fit Straight Line (BFSL) fitted to the output measured over the pressure range
at 25°C. Includes all errors due to pressure non-linearity, pressure
hysteresis, and non-repeatability. 5Offset: The output signal obtained when
the reference pressure is applied to all available pressure ports. Also known
as “null” or “zero”. 6Full Scale Span: The algebraic difference between the
output signal measured at the maximum and minimum limits of the pressure range
(see Figure 1 for pressure ranges). 7Thermal effect on offset: The deviation
in offset due to changes in temperature over the compensated temperature
range, relative to offset measured at 25ºC. 8Thermal effect on span: The
deviation in full scale span due to changes in temperature over the
compensated temperature range, relative to full scale span measured at 25ºC.
9Thermal hysteresis: The maximum difference between output readings when the
same temperature is reached consecutively, under the same operating
conditions, with temperature approaching from opposite directions within the
operating temperature range. Validated over the full operating temperature and
pressure ranges using a ~5ºC/ minute ramp and 30 minute dwell. Application
performance may be affected by thermal mass of end user system.
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation
Instructions | sps.honeywell.com/ast | 4
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
Pressure Range Order Code (see Figure 1) Pmin. Pmax. Unit Port 1 Port 2 Port 1
Port 2
Common Mode Pressure3 Pressure Accuracy (%FSS)4
Offset (mV/V)5 Long-Term Stability 1000 hr
at 25°C (%FSS) Thermal Hysteresis No Gel Option (%FSS)9 Thermal Hysteresis
Silicone Gel Option (%FSS)9
TABLE 7. TBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 1 PSI TO 150 PSI
Pressure Range
OverPressure1
Burst Pressure2
Full Scale Span (mV/V)6
Thermal Ef- Thermal Effect
fect on Offset on Span
(%FSS)7
(%FSS)8
10ºC 0ºC 10ºC 0ºC Min. Nom. Max. to to to to
50ºC 85ºC 50ºC 85ºC
GAGE
001PG 0 1 psi 12.7 — 20 — — ±0.20 ±0.075 1.42 1.50 1.61 ±1.00 ±2.05 ±1.00 ±2.00 ±0.40 ±0.35 ±0.50
005PG 0 5 psi 30 — 60 — — ±0.15 ±0.12 4.70 5.00 5.30 ±0.75 ±1.50 ±0.75 ±2.00 ±0.25 ±0.15 ±0.25
015PG 0 15 psi 60 — 115 — — ±0.15 ±0.075 5.06 5.25 5.49 ±0.50 ±0.95 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20
030PG 0 30 psi 115 — 245 — — ±0.15 ±0.075 5.05 5.25 5.45 ±0.50 ±0.95 ±0.50 ±1.50 ±0.25 ±0.10 ±0.20
060PG 100PG 150PG
0 60 psi 145 — 245 — 0 100 psi 245 — 300 — 0 150 psi 245 — 300 —
— ±0.15 ±0.075 5.76 6.00 6.24 ±0.50 ±0.95 ±0.50 ±1.25 ±0.25 ±0.10 ±0.20 — ±0.15 ±0.075 5.83 6.10 6.36 ±0.60 ±0.85 ±0.50 ±1.00 ±0.25 ±0.10 ±0.25 — ±0.15 ±0.075 8.75 9.15 9.54 ±0.40 ±0.60 ±0.50 ±1.00 ±0.15 ±0.10 ±0.15
DIFFERENTIAL
001PD -1 1 psi 12.7 12.7 20 20 150 ±0.20 ±0.075 2.84 3.00 3.22 ±0.50 ±1.05 ±1.00 ±2.00 ±0.20 ±0.20 ±0.25
005PD -5 5 psi 30 30 60 60 150 ±0.15 ±0.12 9.40 10.00 10.60 ±0.40 ±0.75 ±0.75 ±2.00 ±0.15 ±0.10 ±0.15
015PD -15 15 psi 60 60 115 115 150 ±0.15 ±0.075 10.12 10.50 10.98 ±0.25 ±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10
030PD -30 30 psi 115 115 245 245 150 ±0.15 ±0.075 10.10 10.50 10.90 ±0.25 ±0.50 ±0.50 ±1.50 ±0.15 ±0.10 ±0.10
060PD -60 60 psi 145 145 245 245 250 ±0.15 ±0.075 11.52 12.00 12.48 ±0.25
±0.50 ±0.50 ±1.25 ±0.15 ±0.10 ±0.10
1Overpressure: The maximum pressure which may safely be applied to the product
for it to remain within specifications once pressure is returned to the
operating pressure range. Exposure to higher pressures may cause permanent
damage to the product. Unless otherwise specified, this applies to all
available pressure ports at any temperature within the operating temperature
range.
2Burst pressure: The maximum pressure that may be applied to the specified
port (P1 or P2) of the product without causing escape of pressure media.
Product should not be expected to function after exposure to any pressure
beyond the burst pressure.
3Common mode pressure: The maximum pressure that can be applied simultaneously
to both ports of a differential pressure sensor without causing changes in
specified performance.
4Accuracy: The maximum deviation in output from a Best Fit Straight Line
(BFSL) fitted to the output measured over the pressure range at 25°C. Includes
all errors due to pressure non-linearity, pressure hysteresis, and non-
repeatability.
5Offset: The output signal obtained when the reference pressure is applied to
all available pressure ports. Also known as “null” or “zero”.
6Full Scale Span: The algebraic difference between the output signal measured
at the maxumum and minimum limits of the pressure range (see Figure 1 for
pressure ranges).
7Thermal effect on offset: The deviation in offset due to changes in
temperature over the compensated temperature range, relative to offset
measured at 25ºC.
8Thermal effect on span: The deviation in full scale span due to changes in
temperature over the compensated temperature range, relative to full scale
span measured at 25ºC.
9Thermal hysteresis: The maximum difference between output readings when the
same temperature is reached consecutively, under the same operating
conditions, with temperature approaching from opposite directions within the
operating temperature range. Validated over the full operating temperature and
pressure ranges using a ~5ºC/ minute ramp and 30 minute dwell. Application
performance may be affected by thermal mass of end user system.
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 5
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
TABLE 8. NBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 60 MBAR TO 10 BAR
Pressure Range
OverPressure1
Burst Pressure2
Offset4 (mV/V)
Sensitivity
Thermal Effect on Offset Thermal Effect on Span
(mV/V/Full Scale Span)
(%FSS/25ºC)5
(%FSS/25ºC)6
Pressure Range (see Figure 2) Pmin. Pmax.
Unit Port 1 Port 2 Port 1 Port 2 Common Mode
Pressure3
Min. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.
ABSOLUTE
001BA 0
1 bar 2
—
4
—
— -7.0 7.0 10.0 15.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5
1.6BA
0 1.6 bar 4
—
8
—
— -7.0 7.0 12.0 16.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5
2.5BA
0 2.5 bar 4
—
8
—
— -7.0 7.0 18.8 25.0 31.3 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
004BA 0
4 bar 8
— 16 —
— -7.0 7.0 16.8 20.0 23.2 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
006BA 0
6 bar 16 — 20 —
— -7.0 7.0 12.6 15.0 17.4 -1.5 -0.4 1.5 -6.0 -5.0 -3.5
010BA 0
10 bar 16 —
20 —
— -7.0 7.0 21.0 25.0 29.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
GAGE
060MG 0
60 mbar 850 — 1400 —
— -8.5 8.5 3.9 5.7 7.4 -3.5 -1.2 3.5 -6.0 -5.0 -3.5
100MG 0 100 mbar 850 — 1400 —
— -8.5 8.5 6.6 9.4 12.3 -2.1 -0.7 2.1 -6.0 -5.0 -3.5
160MG 0 160 mbar 850 — 1400 —
— -8.5 8.5 10.5 15.1 19.7 -1.3 -0.4 1.3 -6.0 -5.0 -3.5
250MG 0 250 mbar 1800 — 3000 —
— -8.5 8.5 7.3 10.9 14.5 -2.1 -0.7 2.1 -6.0 -5.0 -3.5
400MG 0 400 mbar 1800 — 3000 —
— -8.5 8.5 11.7 17.4 23.2 -1.3 -0.4 1.3 -6.0 -5.0 -3.5
600MG 0 600 mbar 2000 — 4000 —
— -7.0 7.0 6.0 9.0 12.0 -2.5 -1.0 2.5 -6.0 -5.0 -3.5
001BG 0
1 bar 2
—
4
—
— -7.0 7.0 10.0 15.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5
1.6BG
0 1.6 bar 4
—
8
—
— -7.0 7.0 12.0 16.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5
2.5BG
0 2.5 bar 4
—
8
—
— -7.0 7.0 18.8 25.0 31.3 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
004BG 0
4 bar 8
— 16 —
— -7.0 7.0 16.8 20.0 23.2 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
006BG 0
6 bar 16 — 20 —
— -7.0 7.0 12.6 15.0 17.4 -1.5 -0.4 1.5 -6.0 -5.0 -3.5
010BG 0
10 bar 16 —
20 —
— -7.0 7.0 21.0 25.0 29.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
DIFFERENTIAL
060MD -60 60 mbar 850 850 1400 1400 10000 -8.5 8.5 7.8 11.4 14.8 -1.8 -0.6 1.8 -6.0 -5.0 -3.5
100MD -100 100 mbar 850 850 1400 1400 10000 -8.5 8.5 13.2 18.8 24.6 -1.1 -0.4 1.1 -6.0 -5.0 -3.5
160MD -160 160 mbar 850 850 1400 1400 10000 -8.5 8.5 21.0 30.2 39.4 -0.7 -0.2 0.7 -6.0 -5.0 -3.5
250MD -250 250 mbar 1800 1800 3000 3000 10000 -8.5 8.5 14.6 21.8 29.0 -1.1 -0.4 1.1 -6.0 -5.0 -3.5
400MD -400 400 mbar 1800 1800 3000 3000 10000 -8.5 8.5 23.4 34.8 46.4 -0.7 -0.2 0.7 -6.0 -5.0 -3.5
600MD -600 600 mbar 2000 2000 4000 4000 10000 -7.0 7.0 12.0 18.0 24.0 -1.3 -0.5 1.3 -6.0 -5.0 -3.5
001BD -1
1
bar
2
2
4
4 10 -7.0 7.0 20.0 30.0 40.0 -0.8 -0.3 0.8 -6.0 -5.0 -3.5
1.6BD -1.6 1.6 bar 4
4
8
8 10 -7.0 7.0 24.0 32.0 40.0 -0.8 -0.3 0.8 -6.0 -5.0 -3.5
2.5BD -2.5 2.5 bar 4
4
8
8 10 -7.0 7.0 37.6 50.0 62.6 -0.5 -0.2 0.5 -6.0 -5.0 -3.5
004BD -4
4 bar 8
8
16 16 15 -7.0 7.0 33.6 40.0 46.4 -0.5 -0.2 0.5 -6.0 -5.0 -3.5
1Overpressure: The maximum pressure which may safely be applied to the product for it to remain within specifications once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Unless otherwise specified, this applies to all available pressure ports at any temperature within the operating temperature range.
2Burst pressure: The maximum pressure that may be applied to the specified
port (P1 or P2) of the product without causing escape of pressure media.
Product should not be expected to function after exposure to any pressure
beyond the burst pressure.
3Common mode pressure: The maximum pressure that can be applied simultaneously
to both ports of a differential pressure sensor without causing changes in
specified performance.
4Offset: The output signal obtained when the reference pressure is applied to all available pressure ports. Also known as “null” or “zero”.
5TCO (Thermal Effect on Offset): The deviation in offset due to changes in temperature over the specified temperature range, relative to offset measured at 25ºC.
6TCS (Thermal Effect on Span): The deviation in full scale span due to changes in temperature over the specified temperature range, relative to full scale span measured at 25ºC.
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 6
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
TABLE 9. NBP SERIES PRESSURE RANGE SPECIFICATIONS FOR 1 PSI TO 150 PSI
Pressure Range
OverPressure1
Burst Pressure2
Offset4 (mV/V)
Sensitivity
Thermal Effect on Offset Thermal Effect on Span
(mV/V/Full Scale Span)
(%FSS/25ºC)5
(%FSS/25ºC)6
Pressure Range (see Figure 2) Pmin. Pmax.
Unit Port 1 Port 2 Port 1 Port 2 Common Mode
Pressure3
Min. Max. Min. Nom. Max. Min. Nom. Max. Min. Nom. Max.
ABSOLUTE
015PA 0
15 psi 30
—
60
—
— -7.0 7.0 10.3 15.0 20.7 -1.5 -0.6 1.5 -6.0 -5.0 -3.5
030PA 0
30 psi 60
— 120 —
— -7.0 7.0 15.5 21.0 26.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5
060PA 0
60 psi 120 — 240 —
— -7.0 7.0 17.4 21.0 24.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
100PA 0 100 psi 240 — 300 —
— -7.0 7.0 14.5 17.2 20.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5
150PA 0 150 psi 240 — 300 —
— -7.0 7.0 21.7 26.0 30.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
GAGE
001PG 0
1 psi 10 — 20 —
— -8.5 8.5 4.5 6.5 8.5 -3.0 -1.0 3.0 -6.0 -5.0 -3.5
005PG 0
5 psi 30 — 40 —
— -8.5 8.5 10.0 15.0 20.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5
015PG 0
15 psi 30
—
60
—
— -7.0 7.0 10.3 15.0 20.7 -1.5 -0.6 1.5 -6.0 -5.0 -3.5
030PG 0
30 psi 60
— 120 —
— -7.0 7.0 15.5 21.0 26.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5
060PG 0
60 psi 120 — 240 —
— -7.0 7.0 17.4 21.0 24.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
100PG 0 100 psi 240 — 300 —
— -7.0 7.0 14.5 17.2 20.0 -1.0 -0.4 1.0 -6.0 -5.0 -3.5
150PG 0 150 psi 240 — 300 —
— -7.0 7.0 21.7 26.0 30.0 -1.0 -0.3 1.0 -6.0 -5.0 -3.5
DIFFERENTIAL
001PD -1
1
psi 10 10 20 20 150 -8.5 8.5 9.0 13.0 17.0 -1.5 -0.5 1.5 -6.0 -5.0 -3.5
005PD -5
5
psi 30 30 40 40 150 -8.5 8.5 20.0 30.0 40.0 -0.8 -0.3 0.8 -6.0 -5.0 -3.5
015PD -15 15 psi 30 30 60 60 150 -7.0 7.0 20.6 30.0 41.4 -0.8 -0.3 0.8 -6.0 -5.0 -3.5
030PD -30 30 psi 60 60 120 120 150 -7.0 7.0 31.0 42.0 52.0 -0.5 -0.2 0.5 -6.0 -5.0 -3.5
060PD -60 60 psi 120 120 240 240 250 -7.0 7.0 34.8 42.0 48.0 -0.5 -0.2 0.5
-6.0 -5.0 -3.5
1Overpressure: The maximum pressure which may safely be applied to the product
for it to remain within specifications once pressure is returned to the
operating pressure range. Exposure to higher pressures may cause permanent
damage to the product. Unless otherwise specified, this applies to all
available pressure ports at any temperature within the operating temperature
range. 2Burst pressure: The maximum pressure that may be applied to the
specified port (P1 or P2) of the product without causing escape of pressure
media. Product should not be expected to function after exposure to any
pressure beyond the burst pressure. 3Common mode pressure: The maximum
pressure that can be applied simultaneously to both ports of a differential
pressure sensor without causing changes in specified performance.
4Offset: The output signal obtained when the reference pressure is applied to
all available pressure ports. Also known as “null” or “zero”.
5TCO (Thermal Effect on Offset): The deviation in offset due to changes in
temperature over the specified temperature range, relative to offset measured
at 25ºC.
6TCS (Thermal Effect on Span): The deviation in full scale span due to changes
in temperature over the specified temperature range, relative to full scale
span.
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 7
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)
AN: Single axial small barbed port
7,00 [0.276] 43
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
No gel coating option: 10,35 [0.407]
Silicone gel coating option: 10,60 [0.417]
1,02
2,54 TYP.
[0.040 [0.100] 3 4
5,50 [0.217]
3,56 [0.140]
ø0,80
[0.032]
11,00 [0.433]
ø1,91
[0.075]
PIN 1 INDICATOR
12
3,50 [0.138]
ø2,74
[0.108] ø2,32
[0.091] ø6,40
[0.252]
11,70 [0.461
8,64 [0.340]
0,25 TYP. [0.010]
21
2X 2,23 [0.088]
4X 3,81 [0.150]
JJ: Dual radial barbless port
1,50 [0.059] PORT 1
PORT 2
PIN 1 INDICATOR 2X 1,88
[0.074]
4X 0,46 [0.018]
7,00 [0.276] 4 3
No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098] 0,9 [0.04] 5,50 [0.217]
11,00 [0.433]
ø6,40
[0.252]
12
3,50 [0.138]
PORT 1
2,23 [0.088]
5,33 [0.210]
1,02 [0.040]
2,54 TYP.
[0.100] 34
2X 2,23 [0.088]
ø6,40
[0.252]
11,70 [0.461]
ø0,80
[0.032]
PORT 2
0,9 [0.04] 8,64 [0.340]
0,25 TYP. [0.010]
21
JN: Single radial barbless port
3,81 [0.150] 4X 0,46 [0.018] 13,00 MAX. [0.512] 7,00 [0.276] 43
ø1,88
[0.074]
No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]
5,50 [0.217] 11,00 [0.433] 0,75 [0.030]
0,9 [0.04] ø6,41
[0.252]
PIN 1 INDICATOR
12
13,00 MAX. [0.512]
2,3 [0.09]
3,50 [0.138]
4X 3,81 [0.150]
1,02 [0.040]
2,54 TYP.
[0.100] 34
2X 2,23 [0.088]
ø0,80
[0.032] 11,70 [0.461
8,64 [0.340]
0,25 TYP. [0.010]
21
4X 0,46 [0.018] TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 8
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)
KN: Single axial large barbed port
7,00 [0.276] 43
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
No gel coating option: 11,00 [0.433] Silicone gel coating option: 11,25 [0.443]
1,02 [0.040]
2,54 TYP. [0.100] 3 4
2,23 [0.088]
11,00 [0.433]
5,50 [0.217]
3,301 [0.130] ø3,05
[0.120]
ø0,80
[0.032] 11,70 [0.461
PIN 1 INDICATOR
12
3,50
[0.138]
ø4,92
[0.194] ø3,81
[0.150] ø6,40
[0.252]
8,64 [0.340]
0,25 TYP. [0.010]
21
LN: Single axial barbless port
4X 3,81 [0.150]
4X 0,46 [0.018] 7,00 [0.276] 43
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
11,00 [0.433]
5,50 [0.217]
ø3,18
[0.125]
PIN 1 INDICATOR
12
3,50 [0.138]
ø6,40
[0.252]
No gel coating option: 10,35 [0.407]
Silicone gel coating option: 10,60 [0.417]
1,02 [0.040]
2,54 TYP.
2,23
[0.100] 3 4 [0.088]
ø0,80
[0.032]
11,70 [0.461
4X 1,27 [0.050]
8,64 [0.340]
0,25 TYP. [0.010]
2
1
4X 0,46
[0.018]
PN: Low-profile port
4X 3,81 [0.150]
11,00 [0.433]
4X 0,46 [0.018] 7,00 [0.276] 43
3,70 MAX. [0.146] 2,10 MIN. [0.083]
5,50 [0.217]
ø6,50
[0.256]
PIN 1 INDICATOR
12 3,50
[0.138]
4X 3,81 [0.150]
2,54 TYP.
2X 2,23
[0.100] [0.088]
34
ø0,80
[0.032] 11,70 [0.461]
1,02 [0.040] 8,64 [0.340]
0,25 TYP. [0.010]
21
4X 0,46 [0.018] TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 9
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)
RN: Single radial barbed port
ø2,32
[0.091] ø1,91
[0.075] 3,56 [0.140]
7,00 [0.276] 4 3
No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]
5,50 [0.217] 11,00 [0.433] 0,75 [0.030]
1,2 [0.05] ø6,40
[0.252]
1,02 [0.040]
2,54 TYP. [0.100]
2X 2,23 [0.088]
34
ø0,80
[0.032] 11,70 [0.461]
PIN 1 INDICATOR
1
ø2,74
[0.108]
13,00 MAX. [0.512]
2
3,50 [0.138]
2,3 [0.09]
4X 3,81 [0.150]
8,64 [0.340]
0,25 TYP. [0.010]
21
RR: Dual radial barbed port
4X 0,46 [0.018]
ø2,321
[0.091] PORT 1 1,50 [0.059]
7,00 [0.276] 43
No gel coating option: 2,23 [0.088] Silicon gel coating option: 2,48 [0.098]
5,50 [0.217] 11,00 [0.433]
1,2 [0.05] ø6,40
[0.252]
PORT 2
PIN 1
1
INDICATOR
2X ø1,91
[0.075] 13,00 MAX.
[0.512]
2
3,50 [0.138]
PORT 1
2,23 [0.088]
1,02 [0.040] PORT 2
2,54 TYP.
[0.100] 34
ø6,40
[0.252]
11,70 [0.461
2X 2,23 [0.088] 0,75 [0.029]
1,2 [0.05] 8,64 [0.340]
0,25 TYP. [0.010]
21
2X 5,33 [0.210] 2X ø2,74
[0.108] VN: Single axial barbless straight port
11,00 [0.433]
4X 3,81 [0.150]
4X 0,46 [0.018]
7,00 [0.276] 43
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [.090]
5,50 [0.217]
ø2,58
[0.101]
PIN 1 INDICATOR
12
3,50
[0.138]
ø6,40
[0.252]
No gel coating option: 8,05 [0.317]
Silicone gel coating option: 8,30 [0.327]
1,02
2,54 TYP.
[0.040] [0.100] 3 4
2X 2,23 [0.088]
ø0,80
[0.032] 11,70 [0.461
8,64 [0.340]
0,25 TYP. [0.010]
21
4X 3,81 [0.150] 4X 0,46 [0.018] TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 10
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
FIGURE 1. DIP PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)
Recommended DIP Package PCB Pad Layout
2,54 [0.100]
DIP PACKAGE PINOUT
PIN
FUNCTION
1
Vsupply
11,50
[0.45]
2
Vout-
3
GND
4
Vout+
ø0,813
[0.032]
FIGURE 2. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].) AN: Single axial small barbed port
7,00 [0.276] 43
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60 [0.417]
1,02 [0.040]
2,54 TYP.
2,23
[0.100] 3
4
[0.088]
11,00 [0.433] PIN 1 INDICATOR
5,50 [0.217] 12 3,50
[0.138]
3,56 [0.140] ø1,91
[0.075] ø2,74
[0.108] ø2,32
[0.091] ø6,40
[0.252]
11,70 [0.461]
ø0,80
[0.032]
3,03 [0.119]
0,25 TYP. [0.010]
2
1
4X 0,46 [0.018]
4X 1,27 [0.050]
JN: Single radial barbless port
1,88 [0.074]
7,00 [0.276] 4 3
No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]
5,50 [0.217]
0,9 [0.04]
11,00 [0.433] 0,75 [0.030]
ø6,41
[0.252]
PIN 1 INDICATOR
12
3,50 [0.138]
13,00 MAX. [0.512]
2,3 [0.09]
1,02 [0.040]
2,54 TYP.
[0.100]
34
ø0,80
[0.032]
2X 2,23 [0.088]
11,70 [0.461]
3,03 [0.119]
0,25 TYP. [0.010]
21
4X 1,27 [0.050]
4X 0,46 [0.018]
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 11
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
FIGURE 2. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.) KN: Single axial large barbed port
7,00 [0.276] 43
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
No gel coating option: 11,00 [0.433] Silicone gel coating option: 11,25 [0.443]
1,02
2,54 TYP.
[0.040] [0.100]
34
11,00 [0.433]
5,50 [0.217]
3,30 [0.130] ø3,05
[0.120]
ø0,80
[0.032] 11,70 [0.461
PIN 1 INDICATOR
12
3,50 [0.138]
ø4,92
[0.194] ø3,81
[0.150] ø6,40
[0.252]
3,03 [0.119]
0,25 TYP. [0.010]
2
1
4X 0,46 [0.018]
2X 2,23 [0.088] 4X 1,27 [0.050]
LN: Single axial barbless port
11,00 [0.433]
7,00 [0.276] 4 3
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
5,50 [0.217]
ø3,18
[0.125]
PIN 1 INDICATOR
12
3,50 [0.138]
ø6,40
[0.252]
No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60 [0.417]
1,02 [0.040]
2,54 TYP. [0.100] 3 4
2,23 [0.088]
ø0,80
[0.032] 11,70 [0.461
4X 1,27 [0.050]
0,25 TYP. 3,03 [0.010] [0.119]
2
1
4X 0,46 [0.018]
PN: Low-profile port
11,00 [0.433] PIN 1 INDICATOR
7,00 [0.276] 4 3
3,70 MAX. [0.010] 2,10 MIN. [0.083]
5,50 [0.217]
ø6,50
[0.256]
2,54 TYP.
[0.100]
34
ø0,80
[0.032] 11,70 [0.461
1
2
3,50 [0.138]
1,02 [0.040]
3,03 [0.119]
0,25 TYP. [0.010]
21
4X 0,46 [0.018]
2,23 [0.088] 4X 1,27 [0.050]
RN: Single radial barbed port
ø1,88
[0.07]
7,00 [0.276] 43
No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]
5,50 [0.217]
0,9 [0.04]
11,00 [0.433] 0,75 [0.030]
ø6,41
[0.252]
PIN 1 INDICATOR
12
3,50 [0.138]
13,00 MAX. [0.512]
2,3 [0.09]
1,02 [0.040]
2,54 TYP.
2,23
[0.100] [0.088]
34
ø0,80
[0.032] 11,70 [0.461]
4X 1,27 [0.050]
3,03 [0.119]
0,25 TYP. [0.010]
21
4X 0,46 [0.018]
4X 0,46 [0.018] TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 12
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
FIGURE 2. SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)
VN: Single axial barbless straight port
7,00 [0.276] 43
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
No gel coating option: 8,05 [0.317] Silicone gel coating option: 8,30 [0.327]
1,02 [0.040]
2,54 TYP. [0.100]
34
2,23 [0.088]
11,00 [0.433]
5,50 [0.217]
ø2,58
[0.101]
ø0,80
[0.032] 11,70 [0.461
PIN 1 INDICATOR
Recommended SMT Package PCB Pad Layout
2,032 [0.080]
12 3,50
[0.138] 2,54 [0.100]
7,49 [0.295]
ø6,40
[0.252]
3,03 [0.119]
0,25 TYP. [0.010]
SMT PACKAGE PINOUT
PIN
FUNCTION
1
Vsupply
2
Vout-
3
GND
4
Vout+
4X 1,27 [0.050] 21
4X 0,46 [0.018]
1,143 [0.045]
FIGURE 3. LEADLESS SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN].)
AN: Single axial small barbed port JN: Single radial barbless port
PIN 1 INDICATOR
7,00 [0.276] PIN 1 INDICATOR
7,00 [0.276]
7,00 [0.276] 3,50 [0.138] 7,00 [0.276]
No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60 [0.417]
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
3,50 [0.138]
3,56 [0.140] ø1,91
[0.075]
ø2,74
[0.108] ø2,32
[0.091] ø6,40
[0.252]
ø0,80
[0.032]
0,73 [0.029] 6
6X 1,25
5
[0.049]
4
1,02 [0.138]
5X 2,00 [0.079]
0,94 [0.037]
No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]
0,73 [0.029]
3,50 [0.138]
ø0,80
[0.032] 6
2,00 [0.079] 1,00
[0.039] 1
2
2,50 TYP.
[0.098]
3
2,00 [0.079] 1,00 [0.039] 1
13,00 MAX. [0.512]
6X 1,25
5
[0.049]
4
2
2,50 TYP.
[0.098]
3
5X 2,00 [0.079]
0,75 [0.030]
ø6,40
[0.252]
2,28 [0.090]
3,50 [0.138] 1,02 [0.040]
1,88 [0.074]
KN: Single axial large barbed port
PIN 1 INDICATOR
7,00 [0.276]
7,00 [0.276]
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
3,30 [0.130]
3,50 [0.138]
ø3,05
[0.120]
3,50 [0.138]
ø4,92
[0.194] ø3,81
[0.150]
ø6,40
[0.252]
No gel coating option: 11,00 [0.433] Silicone gel coating option: 11,25
[0.443] 0,73 [0.029] ø0,80
[0.032] 6
2,00 [0.079] 1,00 [0.039] 1
6X 1,25
5
[0.049]
4
1,02 [0.040]
2
3
5X 2,00 [0.079]
2,50 TYP. [0.098]
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 13
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
FIGURE 3. LEADLESS SMT PACKAGE DIMENSIONAL DRAWINGS (FOR REFERENCE ONLY: MM [IN], CONTINUED.)
LN: Single axial barbless port
PIN 1 INDICATOR
7,00 [0.276]
7,00 [0.276]
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
3,50 [0.138] 3,50 [0.138]
ø3,18
[0.125]
6,32 [0.249] ø6,40
[0.252]
No gel coating option: 10,35 [0.407] Silicone gel coating option: 10,60
[0.417] 0,73 [0.029] ø0,80
[0.032] 6
2,00 [0.079] 1,00
[0.039] 1
6X 1,25
5
[0.049]
4 1,02 [0.040]
2 2,50 TYP.
[0.098] 3
5X 2,00 [0.079]
PN: Low-profile port RN: Single radial barbed port
PIN 1 INDICATOR
7,00 [0.276]
7,00 [0.276]
3,70 MAX. [0.010] 2,10 MIN. [0.083]
3,50 [0.138]
ø6,50
[0.256]
3,50 [0.138]
0,73 [0.029] ø0,80
[0.032] 6
2,00 [0.079] 1,00 [0.039] 1
6X 1,25
5
[0.049]
4
2 2,50 TYP. [0.098] 3
1,02 [0.040]
5X 2,00 [0.079]
PIN 1 INDICATOR
7,00 [0.276]
ø7,00
[0.276]
ø2,32
[0.091]
2,3 [0.09]
ø6,40
[0.252]
0,96 [0.038]
3,50 [0.138]
13,00 MAX. [0.512]
3,50 [0.138]
3,54 [0.139]
No gel coating option: 2,23 [0.088] Silicone gel coating option: 2,48 [0.098]
0,73 [0.029]
ø0,80
[0.032] 6
ø2,73
[0.108]
6X 1,25
5
[0.049]
4
5X 2,00 [0.079]
ø1,91
[0.075]
2,00 [0.079] 1,00 [0.039] 1
2
2,50 TYP.
[0.098]
3
2,3 [0.09]
1,02 [0.040]
VN: Single axial barbless straight port
PIN 1 INDICATOR
7,00 [0.276]
7,00 [0.276]
No gel coating option: 2,03 [0.080] Silicone gel coating option: 2,28 [0.090]
3,50 [0.138]
ø2,58
[0.101]
3,50 [0.138]
ø6,44
[0.254]
No gel coating option: 8,05 [0.317] Silicone gel coating option: 8,30 [0.327]
ø0,80
[0.032]
0,73 [0.029] 6
2,00 [0.079] 1,00
[0.039] 1
6X 1,25
5
[0.049]
4
2 2,50 TYP. [0.098] 3
1,02 [0.040]
5X 2,00 [0.079]
Recommended Leadless SMT PCB Pad Layout
2,54 [0.100]
Gage reference hole: Do not plug.
2,50 [0.098]
5,46 [0.215]
1,27 [0.050]
LEADLESS SMT PINOUT
PIN
FUNCTION
1
Vsupply
2
NC
3
Vout-
4
GND
5
NC
6
Vout+
TBP Series and NBP Series Basic Board Mount Pressure Sensors Installation Instructions | sps.honeywell.com/ast | 14
TBP SERIES AND NBP SERIES BASIC BOARD MOUNT PRESSURE SENSORS
Issue H 50076346
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as being free of defective
materials and faulty workmanship during the applicable warranty period.
Honeywell’s standard product warranty applies unless agreed to otherwise by
Honeywell in writing; please refer to your order acknowledgement or consult
your local sales office for specific warranty details. If warranted goods are
returned to Honeywell during the period of coverage, Honeywell will repair or
replace, at its option, without charge those items that Honeywell, in its sole
discretion, finds defective. The foregoing is buyer’s sole remedy and is in
lieu of all other warranties, expressed or implied, including those of
merchantability and fitness for a particular purpose. In no event shall
Honeywell be liable for consequential, special, or indirect damages.
While Honeywell may provide application assistance personally, through our
literature and the Honeywell web site, it is buyer’s sole responsibility to
determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is
believed to be accurate and reliable as of this writing. However, Honeywell
assumes no responsibility for its use.
WARNING
RISK TO LIFE OR PROPERTY
Never use this product for an application involving serious risk to life or
property without ensuring that the system as a whole has been designed to
address the risks, and that this product is properly rated and installed for
the intended use within the overall system.
Failure to comply with these instructions could result in death or serious
injury.
FOR MORE INFORMATION
Honeywell Advanced Sensing Solutions services its customers through a
worldwide network of sales offices and distributors. For application
assistance, current specifications, pricing or the nearest Authorized
Distributor, visit our website or call:
USA/Canada Latin America Europe Japan Singapore Greater China
+1 302 613 4491 +1 305 805 8188 +44 1344 238258 +81 (0) 3-6730-7152 +65 6355 2828 +86 4006396841
Honeywell Advanced Sensing Technology 830 East Arapaho Road Richardson, TX 75081 sps.honeywell.com/ast
50076346-H-EN | H | 03/21 © 2021 Honeywell International Inc.