“`html
Specifications
-
Product: Surge Protective Devices
STCPOE65FF -
Connection Type: RJ-45 Female-to-Female
-
Dimensions: 0.8 in. / 20.3 mm (H) x 2.3 in. /
58.4 mm (W) x 1.0 in. / 25.4 mm (D) -
Operating Voltage: Up to 57 VDC
-
Breakdown Voltage: 68 VDC
-
Operating Current: 350 mA
-
Peak Surge Current: Not specified
-
Frequency Range: 0 to 250 MHz
-
Insertion Loss: < 0.1 dB at 20 MHz
-
SPD Technology: Silicon Avalanche Diode
(SAD) -
Operating Temperature: Not specified
-
Weight: Not specified
-
Limited Warranty: Not specified
Product Usage Instructions
Safety Information
Please read the safety information provided in the user manual
carefully before proceeding with installation or operation. Only
qualified personnel should handle electrical equipment.
Installation Instructions
-
Turn off all power supplying the equipment before starting any
work. -
Mount the Surge Protective Device (SPD) as close as possible to
the equipment that needs protection. -
Connect the STCPOE65FF supply cable (with RJ-45 connector) to
the IN side of the SPD. -
Connect the STCPOE65FF supply cable (with RJ-45 connector) to
the OUT side of the SPD and connect it to the equipment.
FAQ
Q: What is the purpose of the Surge Protective Devices
STCPOE65FF?
A: The STCPOE65FF is designed to limit surges and transients on
Category 5 Power-Over-Ethernet transmission lines and Category 6
applications, providing protection to computers and video
equipment.
Q: Are there any safety warnings associated with the
product?
A: Yes, it is important to note that this product may expose
users to chemicals known to the State of California to cause cancer
and birth defects or other reproductive harm. Please refer to the
provided website for more information.
“`
Surge Protective Devices
STCPOE65FF
RJ-45 Female-to-Female
Dimensions: (in./[mm])
0.8 [20.3]
2.3 [58.4] 2
IN
1
1.0 [25.4]
Low Capacitance Neg Steering Diodes
Circuit Diagram
Typical (4x)
Silicon Avalanche
Diodes
2 OUT 1
Low Capacitance Pos Steering Diodes
General Technical Specifications
Operating Voltage
Up to 57 VDC
Breakdown Voltage Operating Current
68 VDC 350 mA
Peak Surge Current
60 A (10 x 1000 µs)
Frequency Range Insertion Loss
0 to 250 MHz < 0.1 dB at 20 MHz
SPD Technology
Silicon Avalanche Diode (SAD)
Connection Type
Female-Female RJ-45 Jacks
Operating Temperature Dimensions (in. / mm.) Weight (oz. / kg.) Limited warranty
-40°C to +85°C 0.8 x 1.0 x 2.3 in. [20.3 x 25.4 x 58.4 mm.] 1 oz. [0.02 kg.] 5 year
Safety Information
Important Information
Read these instructions carefully and look at the equipment to become familiar
with the device before trying to install, operate, service or maintain it. The
following special messages may appear throughout this bulletin or on the
equipment to warn of potential hazards or to call attention to information
that clarifies or simplifies a procedure.
The addition of either symbol to a “Danger” or “Warning” safety label
indicates that an electrical hazard exists which will result in personal
injury if the instructions are not followed.
This is the safety alert symbol. It is used to alert you to potential personal
injury hazards. Obey all safety messages that follow this symbol to avoid
possible injury or death.
DANGER
DANGER indicates a hazardous situation which, if not avoided, will result in
death or serious injury.
WARNING
WARNING indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION
CAUTION indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE
NOTICE is used to address practices not related to physical injury. The safety
alert symbol shall not be used with this signal word.
Please Note
Electrical equipment should be installed, operated, serviced, and maintained
only by qualified personnel. No responsibility is assumed by Appleton Grp LLC
d/b/a Appleton Group for any consequences arising out of the use of this
material.
A qualified person is one who has skills and knowledge related to the
construction, installation, and operation of electrical equipment and has
received safety training to recognize and avoid the hazards involved.
STCPOE65FF
Introduction
The SolaHD STCPOE65FF is designed to work on Category 5 Power-Over-Ethernet
transmission lines as well as Category 6 applications. This device limits
surges and transients at computers and video equipment.
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH · Apply appropriate personal
protective equipment (PPE) and follow safe electrical work practices. See NFPA
70E,
NOM-029-STPS or CSA Z462. · This equipment must only be installed and serviced
by qualified electrical personnel. · Turn off all power supplying this
equipment before working on or inside equipment. · Always use a properly rated
voltage sensing device to confirm power is off. · Replace all devices, doors
and covers before turning on power to this equipment. · This equipment must be
effectively grounded per all applicable codes. Use an equipment-grounding
conductor to
connect this equipment to the power system ground. · Confirm that the Surge
Protective Device voltage rating on the module or nameplate label is not less
than the
operating voltage. · Do not place this product in service on any line capable
of supplying more than 350 mA continuously. Failure to follow these
instructions will result in death or serious injury.
WARNING: This product can expose you to chemicals including DINP, which is
known to the State of California to cause cancer, and DIDP which is known to
the State of California to cause birth defects or other reproductive harm. For
more information go to: www.P65Warnings.ca.gov.
Installation
1. Turn off all power supplying this equipment before working on or inside
equipment. 2. Mount the SPD as close as possible to the equipment. 3. Connect
the STCPOE65FF supply cable (with RJ-45 connector) to the IN side of the SPD.
4. Connect the STCPOE65FF supply cable (with RJ-45 connector) to the OUT side
of the SPD and connected
equipment. 5. Replace the barrier, cover/door and/or trim to the equipment. 6.
Equipment may be re-energized after all the above steps are complete.
Technical Support
Website: www.solahd.com Technical Support E-Mail:
solahd.technicalservices@emerson.com Toll-Free:
800-377-4384 USA:
847-268-6651
Warranty
Please refer to the “Terms & Conditions of Sale” document.
While every precaution has been taken to ensure accuracy and completeness in
this manual, Appleton Grp LLC d/b/a Appleton Group assumes no responsibility,
and disclaims all liability for damages resulting from use of this information
or for any errors or omissions.
STCPOE65FF A272-140 Rev. 4 12/2020
The Emerson logo is a trademark and service mark of Emerson Electric Co. Appleton Grp LLC d/b/a Appleton Group. SolaHD is a registered trademark of Appleton Grp LLC. All other marks are the property of their respective owners. © 2020 Emerson Electric Co. All rights reserved.
United States (Headquarters) Appleton Grp LLC 9377 W. Higgins Road Rosemont,
IL 60018 United States T +1 800 621 1506
Australia Sales Office Bayswater, Victoria T +61 3 9721 0348
Korea Sales Office Seoul T +82 2 3483 1555
Europe ATX SAS Espace Industriel Nord 35, rue André Durouchez, CS 98017 80084
Amiens Cedex 2 France T +33 3 2254 1390
China Sales Office Shanghai T +86 21 3338 7000
Canada EGS Electrical Group Canada Ltd. 99 Union Street Elmira ON, N3B 3L7 Canada T +1 888 765 2226
Asia Pacific EGS Private Ltd. Block 4008, Ang Mo Kio Ave 10, #04-16 TechPlace 1, Singapore 569625 T +65 6556 1100
Middle East Sales Office Dammam, Saudi Arabia T +966 13 510 3702
Chile Sales Office Las Condes T +56 2928 4819
PN# 9637_r-
Latin America EGS Comercializadora Mexico S de RL de CV Calle 10 N°145 Piso 3
Col. San Pedro de los Pinos Del. Álvaro Obregon Ciudad de México. 01180 T +52
55 5809 5049
India Sales Office Chennai T +91 44 3919 7300
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>