INSTALL INSTRUCTIONS
PLEASE FIND A QUALIFIED ELECTRICIAN FOR INSTALLATION.
Please read the instructions before you install and use the linear tube(s).
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
DANGER – RISK OF SHOCK – DISCONNECT POWER BEFORE INSTALLATION.
WARNING – Risk of fire or electric shock. LED Retrofit kit installation
requires knowledge of luminaires electrical systems. If not qualified, do not
attempt installation and contact a qualified electrician.
WARNING – Risk of fire or electric shock. Product must be installed in
accordance with the national electrical code or your local electrical code. If
you are not familiar with these codes and requirements, contact a qualified
electrician.
WARNING – Risk of fire or electric shock. Install this kit only in the
luminaires that have the construction features and dimensions shown in the
photographs and/or drawings and where the input rating of the retrofit kit
does not exceed the input rating of the luminaire.
WARNING – To prevent wiring damage or abrasion, do not expose wiring to
edges of sheet metal or other sharp objects. Do not make or alter any open
holes in an enclosure of wiring or electrical components during kit
installation.
WARNING – To avoid potential fire or shock hazard, do not use this
retrofit kit in luminaires employing shunted bi-pin lampholders. Note: Shunted
lamp holders are found only in fluorescent luminaires with Instant-Start
ballasts. Instant start ballasts can be identified by the words “Instant
Start” or “I.S.” marked on the ballast. This designation may be in the form of
a statement pertaining to the ballast itself, or may be combined with the
marking for the lamps with which the ballast is intended to be used, for
example F40T12/IS. For more information, contact the LED luminaire retrofit
kit manufacturer.
Installers should not disconnect existing wires from lampholder terminals to
make new connections at lampholder terminals. Instead installers should cut
existing lampholder leads away from the lampholder and make new electrical
connections to lampholder lead wires by employing applicable connectors.
WARNING – Risk of fire or electric shock. Luminaire wiring and electrical
parts may be damaged when installing of retrofit kit hardware. Check for
enclosed wiring and components.
WARNING – Risk of fire or electric shock. Check the existing wiring for
damage before installing upgrade kit. Do not install if existing wires are
damaged.
The retrofit kit is accepted as a component of a luminaire where the
suitability of the combination shall be determined by authorities having
jurisdiction.
Product must be installed by a qualified electrician in accordance with the
applicable and appropriate electrical codes. The installation guide does not
supersede local or national regulations for electrical installation. “This
luminaire has been modified and can no longer operate the originally intended
lamp,’’ shall be marked on the retrofit luminaire where readily visible by the
user during normal maintenance including re-lamping.
Do not use with dimmers.
Suitable for damp locations.
Suitable for enclosed luminaires.
This device is not intended for use with emergency exit fixtures.
WARNING – Disconnect power or circuit breaker before installing or servicing.
SINGLE ENDED WIRING INSTRUCTIONS
-
Make sure the circuit breaker that supplies the power to the fixture is turned off.
-
Remove lens or diffuser cover (if applicable) and existing fluorescent lamps.
-
Open/Remove ballast wiring compartment cover.
-
Identify the line and neutral wires running from the breaker box to the ballast and confirm the power is off using a voltmeter.
-
Cut all wires connected to ballast, and remove ballast (and starter if present). Dispose of removed ballast and fluorescent lamps in accordance with government regulations in your area.
-
Ensure that the fixture contains R17d lamp holders.
-
Make sure all sockets are replaced and wired according to the appropriate wiring diagram. (Figure 1, 2, 3, 4 – on Page 2).
-
Reinstall the ballast cover to hide all wires.
-
Install your new LED single ended T8 replacement lamps. These LED
T8 lamps are designed for single ended wiring only. When installing, confirm only the input end of the lamp is powered, and securely connected to the powered R17d lamp holders. -
Apply Re-lamping Label on a visible location inside the fixture.
-
Reinstall lens or diffusion cover on the light fixture.
-
Turn power on at the breaker box.
-
Turn on the lights.
SINGLE ENDED WIRING INSTRUCTIONS
Non-shunted Sockets
WARNING – Disconnect power or circuit breaker before installing or servicing.
RETROFIT WITH ONE LAMP
RETROFIT WITH TWO LAMPS
RETROFIT WITH THREE/FOUR LAMPS
RETROFIT WITH THREE/FOUR LAMPS & TWO BALLASTS
PREMIUM QUALITY LIGHTING®•www.PQLighting.com
© P.Q.L., Inc. • 2285 Ward Avenue • Simi Valley, CA 93065
•800-323-8107