Introduction

H801RS has eight outputs, supports a maximum of 8192 pixels, it Supports the Art-Net protocol, and can work with the DMX console or set the address for DMX chips .H801RS also can add or delete DAT files through the LAN.

Features

  1. Eight output ports control a maximum of 8192 pixels, and each port controls a maximum of 1024 pixels.
  2. SD card supports FAT32, FAT16 format; maximum capacity is 64G bytes, stores up to 64 DAT files.
  3. It can Synchronization controlled by LAN. It can switch files by sending UDP instructions to Network Port 2 or get the serial number of the playing files.
  4. H801RS can be connected to the DMX console, replace files, and adjust speed and brightness and responses quickly
  5. It supports ART-NET protocol and can directly use ART-NET software such as MADRIX and JINX.
  6. Supporting Encryption Function of Restricting Power-on Number and DAT File Encryption
  7. Support set DMX address for DMX chips.
  8. Support online firmware upgrade.

Instructions

  1. SD card must be formatted into FAT32 or FAT16 after times of deleting or adding files. Supports SDHC (high capacity SD card), the maximum capacity is 64G bytes, and stores up to 64 DAT files, which are played based on the file name in alphabetic order.

  2. Eight output ports, control maximum of 8192 pixels. Each port controls a maximum of 1024 pixels.

  3. When power is on, LCD first line shows the model of the controller, and the second line shows the version number, press the “MENU” key, and then power on, the controller automatically upgrades the firmware.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
1

  4. Three buttons are “MENU”, “OK”, “-” and “+”. Press “MENU” to switch mode, press “-” or “+” to set. Press “OK” to save parameters or enter the submenu

  5. File X:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
2X is a sequence number and refers to the playing DAT file name. Press “+” to the next file, and press “-” to the previous file.

  6.  Speed:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
3Play speed ranges from 1 to 100 frames per second

  7. Bright:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
4The brightness range is 0—15.

  8. Cycle Mode:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
5“All” refers to playing all DAT files in SD card circularly; “Single” refers to playing the current file and can be switched by “+” or “-”

  9. Network Port 2 Working Mode:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
6Usually, we choose Net2 Input. When synchronizing in LAN, one of them must be set to “Net2 Send Sync” and the other to “Net2 Input”.

  10. Ip setting:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
7The first three bytes are adaptive. The same IP address cannot be found on the same LAN.

  11. IC Type:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
8If don’t choose IC Type, it is controlled by the IC type specified in the DAT file.
    If choose IC Type, the IC type in the DAT file is invalid

  12. Port Output Mode:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
9Port output mode, 245 or 485. Press ”+”, and”-”to choose, and press “OK” to save.TTL ic, usually select 245, DMX512 ic select 485.

  13. DMX Address:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
10The range is 1-512. Each controller occupies seven channels.
    Press ”OK” to save. The first channel is brightness, the Second channel is red, The third channel is green, the Fourth channel is blue, and the Fifth channel files,
    The sixth channel is speed, the seventh channel is Direction, 0-3 is positive, and other values are reversed.

  14. The tenth menu is the folding menu. Press “▲”,” ▼” to select the submenu, press OK to enter the submenu, and then press MENU to switch the submenu.

LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
11

  1. DMX Addressing menu :
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
12Press “ok” and enter the addressing menu, Set the number of color components of one pixel, the default is 3, which is RGB. The range is 1-4. Press “ok” to save and then press ”MENU” to enter the next step.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
13Choose your DMX IC type. Press “ok” to save, and “MENU” to enter the next step.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
14The number of light channels set the number of channels occupied by a lamp or transcoder board. If it is a point light source, this value is the same as the number of color components.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
15Start DMX address, Press OK after entering the starting channel. Please wait a few seconds for the coding to complete. Press the “MENU” key to return to the main menu.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
16

  2. ART-NET setting:
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
17Start university setting
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
18Set how many channels with each port
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
19Set up the Art-net controller, how many controllers are used
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
20

  3. Count Pixel control
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
21Pixel channel set the number of pixel channels, default to 3, that is RGB. The range is 1-4.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
22Start at the First pixel, and press“▲”,” ▼” to add pixels.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
23Controller Internal Control
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
24

  4. Another setting
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
25Sub control number, When a router or switch is used to form a multi-branch network, a branch control number should be set. When the number is 1, please choose automatically. If online and connected to the computer on the same LAN, it must be set to automatic.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
26Insert W, control RGBW LED strip by inserting W into RGB format.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
27Restore default settings
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
28

  5. Set the password. In the light modeling window of “LED Programming Software”, click the menu “Setting” – – “Controller password”, pop up the encryption dialog box, and select the controller encryption. The encryption method is to limit the number of power-on. After the first encryption, the second encryption can be performed without decryption to prolong the usage.

LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
29

LAN Synchronization

  1. Several H801RS make up a LAN through routers and switches.  Pay attention to the IP address set in the same network segment. (Controllers that support this function can also be synchronized by mixing different models, only one sent is needed, but the number of DAT files and the number of frames per DAT file must be the same).
  2. One H801RS is set to “send synchronization in network port 2” and the other H801RS is set to “input in network port 2”, which can be synchronized when offline.
  3. Connecting the computer to this LAN can realize detachable control.
  4. Programmers who understand UDP can switch files through UDP protocol. The port is 0x2018, sending: 0xA8, 0x20, file three-byte contents, file is program serial number, starting from 0. Send: 0xA8, 0x30 Two bytes can get the serial number of the current playing file: 0xA8, 0x31, file.

Add or delete DAT files

  1. Connect H801RS to a computer or to the same router. Note that the IP address of H801RS does not conflict with other devices on the LAN.

  2. Open click “Tool” ——“send files”, Software Auto-Search Controller, Display File Name in SD Card, Select a File, Click Delete to Delete the File
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
30

  3. Click Send DAT File, pop up the dialog box, select the DAT file you want to add, and click Open, the progress bar shows the progress of sending, prompts the successful sending after completion, and click OK to refresh the list of files just sent.
    LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
31

Controller upgrade

First, connect H801RS to the Internet, hold down the “MENU” key, and then power it on. The controller will be upgraded automatically. After the upgrade is completed, it will be restarted automatically, and the version number will be changed.

Interface Definition

GND
D-1
D+1| GND
CLK1
DAT1
---|---
GND
D-2
D+2| GND
CLK2
DAT2
GND
D-3
D+3| GND
CLK3
DAT3
GND
D-4
D+4| GND
CLK4
DAT4
GND
D-5
D+5| GND
CLK5
DAT5
GND
D-6
D+6| GND
CLK6
DAT6
GND
D-7
D+7| GND
CLK7
DAT7
GND
D-8
D+8| GND
CLK8
DAT8

Specification

Input Voltage: DC24V
Power Consumption: 2W
Drive Pixels Number: 8192
Weight: 1.2KG
Size: L270 x W147 x H43

Connection with LED strip

Connect with DMX-led strip

LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
32

Connect with SPI-led strip

LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller -
33

Documents / Resources

| LED LIGHTING HUT H801RS 8 Ports Artnet DMX to SPI LED Controller [pdf] Instruction Manual
H801RS, 8 Ports Artnet DMX to SPI LED Controller, H801RS 8 Ports Artnet DMX to SPI LED Controller
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals