THE CROW SH-TEMP-PRB-XT Two Way Wireless Temperature Sensor Instruction Manual
- June 8, 2024
- THE CROW
Table of Contents
SH‐TEMP‐PRB‐XT
TWO WAY WIRELESS
TEMPERATURE SENSOR
INSTRUCTION MANUAL
P/N 7105965 Rev A (D.Z)
PRODUCT FEATURES
The SH-TEMP-PRB-XT is an advanced temperature sensor with integrated RF
transceiver designed to be a fully supervised low-current device.
The SH-TEMP-PRB-XT is a part of the FREEWAVE2 devices that uses an advanced
2way RF transceiver combined with an intelligent communication protocol.
Temperature over the external sensor by using unique cord with NTC connected
to the external input (e.g. measure freezer internal temperature)
Temperature measurements are transmitted to the control panel.
Each SH-TEMP-PRB-XT has a unique factory set ID code (24bit) which by
registration is set into memory of the paired FREEWAVE2 TRANSCEIVER, enabling
more secured communication and devices be remotely controlled from a specific
transceiver.
DETECTOR OPENING
Unscrew the holding screw and remove the front cover Gently twist the PCB board to disengage it from the plastic cover.
KNOCKOUT HOLES
Detector mounting:
Place the screws and make sure you tighten the tamper screw (middle screw)
easily, so the back tamper switch will press the switch successfully when the
PCB placed back.
SENSOR DESCRIPTION
PAIRING PROCESS
For pairing process, please refer to your control panel instructions.
To pair your device with Control panel, please proceed as follows:
1. Login installer mode via the “Installer Webpage”
2. Go to “Zones” and select the zone # you want to learn
-
Add Zone ‐Type “ISM”, insert device SN. (device’s ID) The system automatically detects the device type “Temperature”
-
Set the detector configuration:
“Refrigerated storage” ‐ Pre‐set temperatures
“Room temperature” ‐ Pre‐set temperature
“Custom” – Temperature setting according to customer requirement, Please see more details in this manual section THRESHOLD SETTINGS.
save configuration. -
Place a battery as instructed in Figure 4 and wait until the Red / Green LED stops blinking.
-
The device should register to the Control Panel.
-
When registration process is successfully completed, the Green LED will constantly light ON for 3 seconds and then turn O FF.
-
If Green LED continues flashing more than 5 minutes and stopped, please check the SH‐TMP SN, remove battery and repeat steps 3, 4,5.
-
In order to receive alarm of High/Low temp’ and warning, the working mode should set “24 hour auto reset”.
-
Please see THRESHOLD SETTINGS for device configuration
BATTERY INSERTION
Insert the supplied battery into the battery by respecting polarity.
LED on device will start blinking. Please refer to above para “Learning
process” for device registration.
SENSOR LED DESCRIPTION
GREEN / RED Led flashes 6 times alternately:
Sensor has been successfully registered into the control panel.
The cover may placed back and closed.
GREEN Led blinks 20 times:
Sensor is not registered into the control panel.
Please refer to above para. “Pairing Process” for pairing instructions.
RED Led blinks continually (over 20 seconds):
Battery voltage is critically low.
The device may not work correctly. Please refer to para.
“Battery Replacement” below.
SELECT MOUNTING LOCATION
It is recommended to mount the Temperature sensor vertically on a flat area to
get maximum range.
As the device is a wireless transceiver, and in order to take full advantage
of its sophisticated operation, do not install the SHTEMP-PRB in areas where
large metal objects or surfaces can interfere with the transmission of
signals. Do not place on a ferromagnetic surface.
THRESHOLD SETTINGS
In custom working mode, 3 temperature thresholds can be set: high, normal and
low.
Warning alert Time Value – The time (minutes) when the temperature should be
above the normal threshold before the “Attention Temperature Alarm” is
reported.
A high and low temperature alarm will be report after 3 samples (one sample
per minute) beyond the temperature threshold.
Note that a high, Attention or low temperature alarm restore report will only
be received after 3 samples (one sample per minute) when the temperature is
back between the normal and low threshold.
The device provides a temperature update every minute trough the device status
report (supervision) see example Figure 6
BATTERY REPLACEMENT
The battery can be replaced by the user.
The battery must be replaced by 3V Lithium Models such as GP CR123A
CAUTION
RISK OF EXPLOSION
IF BATTERY IS REPLACED BY DIFFERENT TYPE / MODEL.
DISPOSE USED BATTERIES ACCORDING TO ITS INSTRUCTIONS
SPECIFICATION
Detection Method | External Wired Probe Sensor |
---|---|
ISM Radio | 2GFSK |
Operating
Frequencies| 868-869MHz / 916-917MHz
Identification| Unique ID serial number – 24 bit
Events Transmission| Alarm, Tamper, Supervision,Low Bat, Keep Alive.
Supervision Time| 1 min preprogrammed (its not configurable)
Transmission Range| 500m in open space
Battery| 3V Type CR123A Lithium
Battery life| Up to 5 years
Current| Standby ~20 mA
Receive mode ~55 mA
Transmit mode ~16 mA
Consumptions| Low Bat 2.5V
Cut Off 2.2V
Tamper Switch| Front Cover and Wall Removal
Operating temperature| -10°C to +55°C
Probe Température Measurement| -40°C to +105°C
Dimensions| 97mm x 22mm x 21mm
Weight (incl. battery)| 100 gr.
THRESHOLD SETTINGS Example
Get Cache Data
The system can provide temperature values log up to the last 48 hours.
- Enter the installer mode and go to overview level
- Locate the Temperature detector zone number and click the statistic button located in the zone statistics column.
- Click the Get Cached data button and wait for three steps to complete successfully.
- Click the download button to download the file, review the file.
WARRANTY POLICY CERTIFICATE
Crow warrants these products to be free from defects in materials and
workmanship under normal use and service for a period of 24 months from the
last day of the week and year whose numbers are printed on the printed circuit
board inside these products.
Subject to the provisions of this Warranty Certificate, during the Warranty
Period, Crow undertakes, at its sole discretion and subject to Crow’s
procedures, as such procedures are form time to time, to repair or replace,
free of charge for materials and/or labor, products proved to be defective in
materials or workmanship under
normal use and service. Repaired products shall be warranted for the remainder
of the original Warranty Period.
All transportation costs and in-transit risk of loss or damage related,
directly or indirectly, to products returned to Crow for repair or replacement
shall be borne solely by the Purchaser.
This Warranty Certificate does not cover products that is defective (or shall
become defective) due to: (a) alteration of the products (or any part thereof)
by anyone other than Crow; (b) accident, abuse, negligence, or improper
maintenance; (c) failure caused by a product which Crow did not provide; (d)
failure caused by software or hardware which Crow did not provide; (e) use or
storage other than in accordance with Crow’s specified operating and storage
instructions.
There are no warranties, expressed or implied, of merchantability or fitness
of the products for a particular purpose or otherwise, which extend beyond the
description on the face hereof.
This limited Warranty Certificate is the Purchaser’s sole and exclusive remedy
against Crow and Crow’s sole and exclusive liability toward the Purchaser in
connection with the products, including without limitation – for defects or
malfunctions of the products. This Warranty Certificate replaces all other
warranties and liabilities, whether oral, written, (non-mandatory) statutory,
contractual, in tort or otherwise.
In no case shall Crow be liable to anyone for any consequential or incidental
damages (inclusive of loss of profit, and whether occasioned by negligence of
the Crow or any third party on its behalf) for breach of this or any other
warranty, expressed or implied, or upon any other basis of liability
whatsoever.
Crow does not represent that these products can not be compromised or
circumvented; that these products will prevent any person injury or property
loss or damage by burglary, robbery, fire or otherwise; or that these products
will in all cases provide adequate warning or protection.
Purchaser understands that a properly installed and maintained product may in
some cases reduce the risk of burglary, fire, robbery or other events
occurring without providing an alarm, but it is not insurance or a guarantee
that such will not occur or that there will be no personal injury or property
loss or damage as a result.
Consequently, Crow shall have no liability for any personal injury; property
damage or any other loss based on claim that these products failed to give any
warning.
If Crow is held liable, whether directly or indirectly, for any loss or damage
with regards to these products, regardless of cause or origin, Crow’s maximum
liability shall not in any case exceed the purchase price of these products,
which shall be the complete and exclusive remedy against Crow.
sales@crow.co.il
support@crow.co.il
www.thecrowgroup.com
These instructions supersede all previous issues in circulation prior to
December 2021
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>